Detection of a Meal Using Continuous Glucose Monitoring
Open accessThe DOI matches its Crossref record.
Abstract
OBJECTIVE—The purpose of this study was to introduce a novel meal detection algorithm (MDA) to be used as part of an artificial β-cell that uses a continuous glucose monitor (CGM). RESEARCH DESIGN AND METHODS—We developed our MDA on a dataset of 26 meal events using records from 19 children aged 1–6 years who used the MiniMed CGMS Gold. We then applied this algorithm to CGM records from a DirecNet pilot study of the FreeStyle Navigator continuous glucose sensor. During a research center admission, breakfast insulin was withheld for 1 h, and discrete glucose levels were obtained every 10 min after the meal. RESULTS—Based on the Navigator readings, the MDA detected a meal at a mean time of 30 min from the onset of eating, at which time the mean serum glucose was 21 mg/dl above baseline (range 2–36 mg/dl), and >90% of meals were detected before the glucose had risen 40 mg/dl from baseline. CONCLUSIONS—The MDA will enable automated insulin dosing in response to meals, facilitating the development of an artificial pancreas.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Electrochemical Glucose Sensors and Their Applications in Diabetes Management
Heller, A., & Feldman, B. (2008) · Chemical Reviews · doi:10.1021/cr068069y · Cited by 1,707
Diabetes: Models, Signals, and Control
Cobelli, C., Dalla Man, C., Sparacino, G., Magni, L., De Nicolao, G., & Kovatchev, B. P. (2009) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2009.2036073 · Cited by 511
“context, a meal detection and estimation module [258], [276],”
Closed-loop insulin delivery from bench to clinical practice
Hovorka, R. (2011) · Nature Reviews Endocrinology · doi:10.1038/nrendo.2011.32 · Cited by 342
Kovatchev, B., Cobelli, C., Renard, E., Anderson, S., Breton, M., Patek, S., Clarke, W., Bruttomesso, D., Maran, A., Costa, S., et al. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400611 · Cited by 200
Clarke, W. L., Anderson, S., Breton, M., Patek, S., Kashmer, L., & Kovatchev, B. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300506 · Cited by 185
Metadata
- Authors
- Dassau, E., Bequette, B. W., Buckingham, B. A., & Doyle, F. J.
- Venue
- Diabetes Care
- Publisher
- American Diabetes Association
- Published
- 2008-02-01
- Volume
- 31
- Issue
- 2
- Pages
- 295-300
- ISSN
- 0149-5992 (ISSN-L)
- 1935-5548
- OpenAlex
- W2111489741
- Cited by
- 143
- References
- 0
- FWCI
- 7.41
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Detection of a Meal Using Continuous Glucose Monitoring. https://app.cochat.ai/papers/10.2337/dc07-1293
- The paper
- Dassau, E., Bequette, B. W., Buckingham, B. A., & Doyle, F. J. (2008). Detection of a Meal Using Continuous Glucose Monitoring. Diabetes Care. https://doi.org/10.2337/dc07-1293
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.