CoChat

Detection of a Meal Using Continuous Glucose Monitoring

Open access
Dassau, Eyal, Bequette, B. Wayne, Buckingham, Bruce A., Doyle, Francis J. · 2008 · Diabetes Care
Cited by 143

The DOI matches its Crossref record.

Abstract

OBJECTIVE—The purpose of this study was to introduce a novel meal detection algorithm (MDA) to be used as part of an artificial β-cell that uses a continuous glucose monitor (CGM). RESEARCH DESIGN AND METHODS—We developed our MDA on a dataset of 26 meal events using records from 19 children aged 1–6 years who used the MiniMed CGMS Gold. We then applied this algorithm to CGM records from a DirecNet pilot study of the FreeStyle Navigator continuous glucose sensor. During a research center admission, breakfast insulin was withheld for 1 h, and discrete glucose levels were obtained every 10 min after the meal. RESULTS—Based on the Navigator readings, the MDA detected a meal at a mean time of 30 min from the onset of eating, at which time the mean serum glucose was 21 mg/dl above baseline (range 2–36 mg/dl), and >90% of meals were detected before the glucose had risen 40 mg/dl from baseline. CONCLUSIONS—The MDA will enable automated insulin dosing in response to meals, facilitating the development of an artificial pancreas.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2337/dc07-1293

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Dassau, E., Bequette, B. W., Buckingham, B. A., & Doyle, F. J.
Venue
Diabetes Care
Published
2008-02-01
Volume
31
Issue
2
Pages
295-300
ISSN
  • 0149-5992 (ISSN-L)
  • 1935-5548
OpenAlex
W2111489741
Cited by
143
References
0
FWCI
7.41
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.