Real-Time Continuous Glucose Monitoring in Critically Ill Patients
Open accessThe DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To evaluate the impact of real-time continuous glucose monitoring (CGM) on glycemic control and risk of hypoglycemia in critically ill patients. RESEARCH DESIGN AND METHODS: A total 124 patients receiving mechanical ventilation were randomly assigned to the real-time CGM group (n = 63; glucose values given every 5 min) or to the control group (n = 61; selective arterial glucose measurements according to an algorithm; simultaneously blinded CGM) for 72 h. Insulin infusion rates were guided according to the same algorithm in both groups. The primary end point was percentage of time at a glucose level <110 mg/dl. Secondary end points were mean glucose levels and rate of severe hypoglycemia (<40 mg/dl). RESULTS: Percentage of time at a glucose level <110 mg/dl (59.0 ± 20 vs. 55.0 ± 18% in the control group, P = 0.245) and the mean glucose level (106 ± 18 vs. 111 ± 10 mg/dl in the control group, P = 0.076) could not be improved using real-time CGM. The rate of severe hypoglycemia was lower in the real-time CGM group (1.6 vs. 11.5% in the control group, P = 0.031). CGM reduced the absolute risk of severe hypoglycemia by 9.9% (95% CI 1.2–18.6) with a number needed to treat of 10.1 (95% CI 5.4–83.3). CONCLUSIONS: In critically ill patients, real-time CGM reduces hypoglycemic events but does not improve glycemic control compared with intensive insulin therapy guided by an algorithm.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Vincent, J. L., Moreno, R., Takala, J., Willatts, S., De Mendonça, A., Bruining, H., Reinhart, C. K., Suter, P. M., & Thijs, L. G. (1996) · Intensive Care Medicine · doi:10.1007/bf01709751 · Cited by 11,674 · cited 1×
“(% of patients in the category) Respiratory failure 15 (24) 13 (21) CPR 12 (19) 15 (25) Sepsis/Septic shock 13 (20) 12 (20) Heart failure 8 (13) 11 (18) Neurologic disease/ Coma 9 (14) 4 (7) Pulmonary embolism 3 (5) 3 (5) GI-bleeding/ALF 3 (5) 2 (4) -”
Le Gall, J.-R. (1993) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.270.24.2957 · Cited by 7,773
Intensive versus Conventional Glucose Control in Critically Ill Patients
(2009) · New England Journal of Medicine · doi:10.1056/nejmoa0810625 · Cited by 5,119
Intensive insulin therapy in the medical ICU
Van den Berghe, G., Wilmer, A., Hermans, G., Meersseman, W., Wouters, P. J., Milants, I., Van Wijngaerden, E., Bobbaers, H., & Bouillon, R. (2006) · New England Journal of Medicine · doi:10.1056/nejmoa052521 · Cited by 3,639 · cited 1×
“In short, this algorithm is a slightly modified version of the algorithm used in the Leuven studies (3,4).”
MethodIntensive insulin therapy and pentastarch resuscitation in severe sepsis
Brunkhorst, F. M., Engel, C., Bloos, F., Meier-Hellmann, A., Ragaller, M., Weiler, N., Moerer, O., Gruendling, M., Oppert, M., Grond, S., et al. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa070716 · Cited by 2,921
Griesdale, D. E. G., de Souza, R. J., van Dam, R. M., Heyland, D. K., Cook, D. J., Malhotra, A., Dhaliwal, R., Henderson, W. R., Chittock, D. R., Finfer, S., et al. (2009) · Canadian Medical Association Journal · doi:10.1503/cmaj.090206 · Cited by 1,096
Vlasselaers, D., Milants, I., Desmet, L., Wouters, P. J., Vanhorebeek, I., van den Heuvel, I., Mesotten, D., Casaer, M. P., Meyfroidt, G., Ingels, C., et al. (2009) · The Lancet · doi:10.1016/s0140-6736(09)60044-1 · Cited by 554 · cited 4×
“In three monocentric studies, intensive insulin therapy to achieve and maintain normoglycemia resulted in decreased morbidity and mortality (3-5).”
BackgroundResultInfluentialThe effect of continuous glucose monitoring in well-controlled type 1 diabetes
Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group (2009) · Diabetes Care · doi:10.2337/dc09-0108 · Cited by 399
Murphy, H. R., Rayman, G., Lewis, K., Kelly, S., Johal, B., Duffield, K., Fowler, D., Campbell, P. J., & Temple, R. C. (2008) · BMJ · doi:10.1136/bmj.a1680 · Cited by 358 · cited 2×
“Several outcome studies using real time CGM in type 1 diabetes and pregnant women with diabetes indicated promising results concerning improved glucose control but also increasing patients’ safety by reducing hypoglycemic events (24,25).”
Background
Cited by
Umpierrez, G. E., Hellman, R., Korytkowski, M. T., Kosiborod, M., Maynard, G. A., Montori, V. M., Seley, J. J., & Van den Berghe, G. (2012) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2011-2098 · Cited by 1,126
Krinsley, J. S., & Preiser, J.-C. (2015) · Critical Care · doi:10.1186/s13054-015-0908-7 · Cited by 174
Continuous glucose monitors and automated insulin dosing systems in the hospital consensus guideline
Galindo, R. J., Umpierrez, G. E., Rushakoff, R. J., Basu, A., Lohnes, S., Nichols, J. H., Spanakis, E. K., Espinoza, J., Palermo, N. E., Awadjie, D. G., et al. (2020) · Journal of Diabetes Science and Technology · doi:10.1177/1932296820954163 · Cited by 170
Blevins, T. C., Bode, B. W., Garg, S. K., Grunberger, G., Hirsch, I. B., Jovanovič, L., Nardacci, E., Orzeck, E. A., Roberts, V. L., & Tamborlane, W. V. (2010) · Endocrine Practice · doi:10.4158/ep.16.5.730 · Cited by 98
Sadhu, A. R., Serrano, I. A., Xu, J., Nisar, T., Lucier, J., Pandya, A. R., & Patham, B. (2020) · Journal of Diabetes Science and Technology · doi:10.1177/1932296820964264 · Cited by 84
Metadata
- Authors
- Holzinger, U., Warszawska, J., Kitzberger, R., Wewalka, M., Miehsler, W., Herkner, H., & Madl, C.
- Venue
- Diabetes Care
- Publisher
- American Diabetes Association
- Published
- 2009-12-10
- Volume
- 33
- Issue
- 3
- Pages
- 467-472
- ISSN
- 0149-5992 (ISSN-L)
- 1935-5548
- OpenAlex
- W2143623075
- Cited by
- 212
- References
- 9
- FWCI
- 10.66
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.