Should 24-h Ambulatory Blood Pressure Monitoring Be Done in Every Patient With Diabetes?
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
ambulatory blood pressure monitoring (ABPM) is a method widely used in hypertension diagnosis and management. Also in diabetic subjects, it may be a powerful tool for a better stratification of cardiovascular risk related to elevated blood pressure (BP), one of the most important causes of morbidity and mortality in this population. This is due to its capacity, as compared with isolated office measurements, to more precisely diagnose and quantify a high BP condition in daily life and to detect alterations of 24-h BP profiles such as absence of nocturnal BP fall, postprandial hypotension, or an increased
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
O'Brien, E., Asmar, R., Beilin, L., Imai, Y., Mallion, J.-M., Mancia, G., Mengden, T., Myers, M., Padfield, P., Palatini, P., et al. (2003) · Journal of Hypertension · doi:10.1097/00004872-200305000-00001 · Cited by 1,655
Self-citationObstructive Sleep Apnea and Type 2 Diabetes
Tasali, E., Mokhlesi, B., & Van Cauter, E. (2008) · Chest · doi:10.1378/chest.07-0828 · Cited by 371
van Ittersum, F. J., Wijering, R. M. J., Lambert, J., Donker, A. J. M., & Stehouwer, C. D. A. (1998) · Journal of Hypertension · doi:10.1097/00004872-199816080-00007 · Cited by 52 · cited 1×
“Unfortunately in diabetic patients, the difference between BP values obtained with the reference auscultatory measurement and with the oscillometric method is not necessarily the same found in nondiabetic subjects (49).”
Result
Cited by
European Society of hypertension position paper on ambulatory blood pressure monitoring
O’Brien, E., Parati, G., Stergiou, G., Asmar, R., Beilin, L., Bilo, G., Clement, D., de la Sierra, A., de Leeuw, P., Dolan, E., et al. (2013) · Journal of Hypertension · doi:10.1097/hjh.0b013e328363e964 · Cited by 1,419
Self-citationKario, K., Shin, J., Chen, C., Buranakitjaroen, P., Chia, Y., Divinagracia, R., Nailes, J., Hoshide, S., Siddique, S., Sison, J., et al. (2019) · The Journal of Clinical Hypertension · doi:10.1111/jch.13652 · Cited by 164
Patterns of ambulatory blood pressure: clinical relevance and application
O'Brien, E., Kario, K., Staessen, J. A., de la Sierra, A., & Ohkubo, T. (2018) · The Journal of Clinical Hypertension · doi:10.1111/jch.13277 · Cited by 40
Ambulatory blood pressure and arterial stiffness in individuals with type 1 diabetes
on behalf of the FinnDiane Study Group, Lithovius, R., Gordin, D., Forsblom, C., Saraheimo, M., Harjutsalo, V., & Groop, P.-H. (2018) · Diabetologia · doi:10.1007/s00125-018-4648-5 · Cited by 30
Metadata
- Authors
- Parati, G., & Bilo, G.
- Venue
- Diabetes Care
- Publisher
- American Diabetes Association
- Published
- 2009-11-01
- Volume
- 32
- Issue
- suppl_2
- Pages
- S298-S304
- ISSN
- 0149-5992 (ISSN-L)
- 1935-5548
- OpenAlex
- W2050747608
- Cited by
- 41
- References
- 3
- FWCI
- 1.78
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Should 24-h Ambulatory Blood Pressure Monitoring Be Done in Every Patient With Diabetes? https://app.cochat.ai/papers/10.2337/dc09-s326
- The paper
- Parati, G., & Bilo, G. (2009). Should 24-h Ambulatory Blood Pressure Monitoring Be Done in Every Patient With Diabetes? Diabetes Care. https://doi.org/10.2337/dc09-s326
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.