CoChat

Comparison of Insulin Glargine 300 Units/mL and 100 Units/mL in Adults With Type 1 Diabetes: Continuous Glucose Monitoring Profiles and Variability Using Morning or Evening Injections

Bergenstal, Richard M., Bailey, Timothy S., Rodbard, David, Ziemen, Monika, Guo, Hailing, Muehlen-Bartmer, Isabel, Ahmann, Andrew J. · 2017 · Diabetes Care
Cited by 122

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: The objective of this study was to compare glucose control in participants with type 1 diabetes receiving insulin glargine 300 units/mL (Gla-300) or glargine 100 units/mL (Gla-100) in the morning or evening, in combination with mealtime insulin. RESEARCH DESIGN AND METHODS: In this 16-week, exploratory, open-label, parallel-group, two-period crossover study (clinicaltrials.gov identifier NCT01658579), 59 adults with type 1 diabetes were randomized (1:1:1:1) to once-daily Gla-300 or Gla-100 given in the morning or evening (with crossover in the injection schedule). The primary efficacy end point was the mean percentage of time in the target glucose range (80–140 mg/dL), as measured using continuous glucose monitoring (CGM), during the last 2 weeks of each 8-week period. Additional end points included other CGM glycemic control parameters, hypoglycemia (per self-monitored plasma glucose [SMPG]), and adverse events. RESULTS: The percentage of time within the target glucose range was comparable between the Gla-300 and Gla-100 groups. There was significantly less increase in CGM-based glucose during the last 4 h of the 24-h injection interval for Gla-300 compared with Gla-100 (least squares mean difference −14.7 mg/dL [95% CI −26.9 to −2.5]; P = 0.0192). Mean 24-h glucose curves for the Gla-300 group were smoother (lower glycemic excursions), irrespective of morning or evening injection. Four metrics of intrasubject interstitial glucose variability showed no difference between Gla-300 and Gla-100. Nocturnal confirmed (<54 mg/dL by SMPG) or severe hypoglycemia rate was lower for Gla-300 participants than for Gla-100 participants (4.0 vs. 9.0 events per participant-year; rate ratio 0.45 [95% CI 0.24–0.82]). CONCLUSIONS: Less increase in CGM-based glucose levels in the last 4 h of the 24-h injection interval, smoother average 24-h glucose profiles irrespective of injection time, and reduced nocturnal hypoglycemia were observed with Gla-300 versus Gla-100.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2337/dc16-0684

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 122

Metadata

Authors
Bergenstal, R. M., Bailey, T. S., Rodbard, D., Ziemen, M., Guo, H., Muehlen-Bartmer, I., & Ahmann, A. J.
Venue
Diabetes Care
Published
2017-01-23
Volume
40
Issue
4
Pages
554-560
ISSN
  • 0149-5992 (ISSN-L)
  • 1935-5548
OpenAlex
W2581151970
Cited by
122
References
8
FWCI
13.73
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.