CoChat

Predictive Hyperglycemia and Hypoglycemia Minimization: In-Home Evaluation of Safety, Feasibility, and Efficacy in Overnight Glucose Control in Type 1 Diabetes

Open access
Spaic, Tamara, Driscoll, Marsha, Raghinaru, Dan, Buckingham, Bruce A., Wilson, Darrell M., Clinton, Paula, Chase, H. Peter, Maahs, David M., Forlenza, Gregory P., Jost, Emily, Hramiak, Irene, Paul, Terri, Bequette, B. Wayne, Cameron, Faye, Beck, Roy W., Kollman, Craig, Lum, John W., Ly, Trang T., for the In-Home Closed-Loop (IHCL) Study Group · 2017 · Diabetes Care
Cited by 29

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: The objective of this study was to determine the safety, feasibility, and efficacy of a predictive hyperglycemia and hypoglycemia minimization (PHHM) system compared with predictive low-glucose insulin suspension (PLGS) alone in overnight glucose control. RESEARCH DESIGN AND METHODS: A 42-night trial was conducted in 30 individuals with type 1 diabetes in the age range 15–45 years. Participants were randomly assigned each night to either PHHM or PLGS and were blinded to the assignment. The system suspended the insulin pump on both the PHHM and PLGS nights for predicted hypoglycemia but delivered correction boluses for predicted hyperglycemia on PHHM nights only. The primary outcome was the percentage of time spent in a sensor glucose range of 70–180 mg/dL during the overnight period. RESULTS: The addition of automated insulin delivery with PHHM increased the time spent in the target range (70–180 mg/dL) from 71 ± 10% during PLGS nights to 78 ± 10% during PHHM nights (P < 0.001). The average morning blood glucose concentration improved from 163 ± 23 mg/dL after PLGS nights to 142 ± 18 mg/dL after PHHM nights (P < 0.001). Various sensor-measured hypoglycemic outcomes were similar on PLGS and PHHM nights. All participants completed 42 nights with no episodes of severe hypoglycemia, diabetic ketoacidosis, or other study- or device-related adverse events. CONCLUSIONS: The addition of a predictive hyperglycemia minimization component to our existing PLGS system was shown to be safe, feasible, and effective in overnight glucose control.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2337/dc16-1794

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 29

Metadata

Authors
Spaic, T., Driscoll, M., Raghinaru, D., Buckingham, B. A., Wilson, D. M., Clinton, P., Chase, H. P., Maahs, D. M., Forlenza, G. P., Jost, E., Hramiak, I., Paul, T., Bequette, B. W., Cameron, F., Beck, R. W., Kollman, C., Lum, J. W., Ly, T. T., & for the In-Home Closed-Loop (IHCL) Study Group
Venue
Diabetes Care
Published
2017-01-18
Volume
40
Issue
3
Pages
359-366
ISSN
  • 0149-5992 (ISSN-L)
  • 1935-5548
OpenAlex
W2579730935
Cited by
29
References
5
FWCI
2.78
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Predictive Hyperglycemia and Hypoglycemia Minimization: In-Home Evaluation of Safety, Feasibility, and Efficacy in Overnight Glucose Control in Type 1 Diabetes. https://app.cochat.ai/papers/10.2337/dc16-1794
The paper
Spaic, T., Driscoll, M., Raghinaru, D., Buckingham, B. A., Wilson, D. M., Clinton, P., Chase, H. P., Maahs, D. M., Forlenza, G. P., Jost, E., Hramiak, I., Paul, T., Bequette, B. W., Cameron, F., Beck, R. W., Kollman, C., Lum, J. W., Ly, T. T., & for the In-Home Closed-Loop (IHCL) Study Group. (2017). Predictive Hyperglycemia and Hypoglycemia Minimization: In-Home Evaluation of Safety, Feasibility, and Efficacy in Overnight Glucose Control in Type 1 Diabetes. Diabetes Care. https://doi.org/10.2337/dc16-1794

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.