Cited by 120Diabetes Management and ResearchDiabetes Management and EducationDiabetes Treatment and Management

Multinational Home Use of Closed-Loop Control Is Safe and Effective

Open access
Anderson, Stacey M., Raghinaru, Dan, Pinsker, Jordan E., Boscari, Federico, Renard, Eric, Buckingham, Bruce A., Nimri, Revital, Doyle, Francis J. +23 more·2016·Diabetes Care

Abstract

OBJECTIVE: To evaluate the efficacy of a portable, wearable, wireless artificial pancreas system (the Diabetes Assistant [DiAs] running the Unified Safety System) on glucose control at home in overnight-only and 24/7 closed-loop control (CLC) modes in patients with type 1 diabetes. RESEARCH DESIGN AND METHODS: At six clinical centers in four countries, 30 participants 18–66 years old with type 1 diabetes (43% female, 96% non-Hispanic white, median type 1 diabetes duration 19 years, median A1C 7.3%) completed the study. The protocol included a 2-week baseline sensor-augmented pump (SAP) period followed by 2 weeks of overnight-only CLC and 2 weeks of 24/7 CLC at home. Glucose control during CLC was compared with the baseline SAP. RESULTS: Glycemic control parameters for overnight-only CLC were improved during the nighttime period compared with baseline for hypoglycemia (time <70 mg/dL, primary end point median 1.1% vs. 3.0%; P < 0.001), time in target (70–180 mg/dL: 75% vs. 61%; P < 0.001), and glucose variability (coefficient of variation: 30% vs. 36%; P < 0.001). Similar improvements for day/night combined were observed with 24/7 CLC compared with baseline: 1.7% vs. 4.1%, P < 0.001; 73% vs. 65%, P < 0.001; and 34% vs. 38%, P < 0.001, respectively. CONCLUSIONS: CLC running on a smartphone (DiAs) in the home environment was safe and effective. Overnight-only CLC reduced hypoglycemia and increased time in range overnight and increased time in range during the day; 24/7 CLC reduced hypoglycemia and increased time in range both overnight and during the day. Compared with overnight-only CLC, 24/7 CLC provided additional hypoglycemia protection during the day.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2337/dc15-2468

Cites

26 of 26 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • In July 2016, Diabetes Care published a symposium featuring several outpatient AID studies using DiAs running in two different in silico designed algorithm configurations.

    “In July 2016, Diabetes Care published a symposium, 129 which featured several outpatient AID studies using DiAs running in two different in silico designed algorithm configurations.[123][124][125]”

    From Developing the UVA/Padova Type 1 Diabetes Simulator: Modeling, Validation, Refinements, and Utility (2023) · cites this paper as [123]

    The Conclusions (page unavailable) describe outpatient and home DiAs studies and name two closed-loop algorithms; this paper reports home use of one, DiAs-USS Virginia. Our copy does not establish that the algorithms were designed in silico. The symposium reference has a separate citation in the citing sentence, so this verdict does not assess it. (LLM, conf=0.83)

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Anderson, S. M., Raghinaru, D., Pinsker, J. E., Boscari, F., Renard, E., Buckingham, B. A., Nimri, R., Doyle, F. J., Brown, S. A., Keith-Hynes, P., Breton, M. D., Chernavvsky, D., Bevier, W. C., Bradley, P. K., Bruttomesso, D., Del Favero, S., Calore, R., Cobelli, C., Avogaro, A., Farret, A., Place, J., Ly, T. T., Shanmugham, S., Phillip, M., Dassau, E., Dasanayake, I. S., Kollman, C., Lum, J. W., Beck, R. W., Kovatchev, B., & for the Control to Range Study Group
Affiliations
  • University of Virginia (US)
  • Jaeb Center for Health Research (US)
  • Sansum Diabetes Research Institute (US)
  • University of Padua (IT)
  • Department of Endocrinology, Diabetes, and Nutrition and INSERM 1411 Clinical Investigation Center, Montpellier University Hospital, and UMR CNRS 5203/INSERM U1191, Institute of Functional Genomics, University of Montpellier, Montpellier, France
  • Stanford Medicine (US)
  • Tel Aviv University (IL)
  • Harvard University (US)
  • University of Virginia, Charlottesville, VA
  • University of Padova, Padova, Italy
  • Centre National de la Recherche Scientifique (FR)
  • University of California, Santa Barbara (US)
Corresponding author
Beck, Roy W.
Venue
Diabetes Care
Published
2016-03-16
Volume
39
Issue
7
Pages
1143-1150
ISSN
  • 0149-5992 (ISSN-L)
  • 1935-5548
OpenAlex
W2335897113
Cited by
120
References
26
Citations by year
2026: 5 · 2025: 9 · 2024: 4 · 2023: 8 · 2022: 6 · 2021: 7 · 2020: 11 · 2019: 22 · 2018: 18 · 2017: 22 · 2016: 8
FWCI
23.45
Type
journal article
Language
en
Open access
Locations
  • Diabetes Care (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
  • Padua Research Archive (University of Padova) (submittedVersion)
  • Digital Access to Scholarship at Harvard (DASH) (Harvard University) (submittedVersion, cc-by)
  • HAL (submittedVersion)
Funders
JDRF (22-2011-649, 17-2013-509)
Topics
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
Keywords
type 1 diabetes, feedback control, artificial pancreas, sensor-augmented pump, hypoglycemia, glycemic control, time in range, glycemic variability
MeSH terms
Smartphone, Adolescent, Adult, Aged, Blood Glucose, Diabetes Mellitus, Type 1, Female, Humans, Hypoglycemia, Hypoglycemic Agents, Insulin, Insulin Infusion Systems, Male, Middle Aged, Blood Glucose Self-Monitoring, Pancreas, Artificial, Internationality, Young Adult, Mobile Applications

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review