CoChat

Home Use of Day-and-Night Hybrid Closed-Loop Insulin Delivery in Very Young Children: A Multicenter, 3-Week, Randomized Trial

Open access
Tauschmann, Martin, Allen, Janet M., Nagl, Katrin, Fritsch, Maria, Yong, James, Metcalfe, Emily, Schaeffer, Dominique, Fichelle, Muriel, Schierloh, Ulrike, Thiele, Alena G., Abt, Daniela, Kojzar, Harald, Mader, Julia K., Slegtenhorst, Sonja, Barber, Nicole, Wilinska, Malgorzata E., Boughton, Charlotte, Musolino, Gianluca, Sibayan, Judy, Cohen, Nathan, Kollman, Craig, Hofer, Sabine E., Fröhlich-Reiterer, Elke, Kapellen, Thomas M., Acerini, Carlo L., de Beaufort, Carine, Campbell, Fiona, Rami-Merhar, Birgit, Hovorka, Roman · 2019 · Diabetes Care
Cited by 100

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: We aimed to assess the feasibility and safety of hybrid closed-loop insulin delivery in children with type 1 diabetes aged 1–7 years as well as evaluate the role of diluted insulin on glucose control. RESEARCH DESIGN AND METHODS: In an open-label, multicenter, multinational, randomized crossover study, 24 children with type 1 diabetes on insulin pump therapy (median age 5 years [interquartile range 3–6] and mean ± SD HbA1c 7.4 ± 0.7% [57 ± 8 mmol/mol] and total insulin 13.2 ± 4.8 units/day) underwent two 21-day periods of unrestricted living and we compared hybrid closed-loop with diluted insulin (U20) and hybrid closed-loop with standard strength insulin (U100) in random order. During both interventions, the Cambridge model predictive control algorithm was used. RESULTS: The proportion of time that sensor glucose was in the target range between 3.9 and 10 mmol/L (primary end point) was not different between interventions (mean ± SD 72 ± 8% vs. 70 ± 7% for closed-loop with diluted insulin vs. closed-loop with standard insulin, respectively; P = 0.16). There was no difference in mean glucose levels (8.0 ± 0.8 vs. 8.2 ± 0.6 mmol/L; P = 0.14), glucose variability (SD of sensor glucose 3.1 ± 0.5 vs. 3.2 ± 0.4 mmol/L; P = 0.16), or the proportion of time spent with sensor glucose <3.9 mmol/L (4.5 ± 1.7% vs. 4.7 ± 1.4%; P = 0.47) or <2.8 mmol/L (0.6 ± 0.5% vs. 0.6 ± 0.4%; P > 0.99). Total daily insulin delivery did not differ (17.3 ± 5.6 vs. 18.9 ± 6.9 units/day; P = 0.07). No closed-loop–related severe hypoglycemia or ketoacidosis occurred. CONCLUSIONS: Unrestricted home use of day-and-night closed-loop in very young children with type 1 diabetes is feasible and safe. The use of diluted insulin during closed-loop does not provide additional benefits compared with standard strength insulin.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2337/dc18-1881

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 100

Metadata

Authors
Tauschmann, M., Allen, J. M., Nagl, K., Fritsch, M., Yong, J., Metcalfe, E., Schaeffer, D., Fichelle, M., Schierloh, U., Thiele, A. G., Abt, D., Kojzar, H., Mader, J. K., Slegtenhorst, S., Barber, N., Wilinska, M. E., Boughton, C., Musolino, G., Sibayan, J., Cohen, N., Kollman, C., Hofer, S. E., Fröhlich-Reiterer, E., Kapellen, T. M., Acerini, C. L., de Beaufort, C., Campbell, F., Rami-Merhar, B., & Hovorka, R.
Venue
Diabetes Care
Published
2019-01-28
Volume
42
Issue
4
Pages
594-600
ISSN
  • 0149-5992 (ISSN-L)
  • 1935-5548
OpenAlex
W2913794762
Cited by
100
References
10
FWCI
11.70
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.