OBJECTIVE: According to recent guidelines, individuals with type 1 diabetes should spend <4.0% of time per day with glucose levels <3.9 mmol/L (<70 mg/dL) and <1.0% per day with glucose levels <3.0 mmol/L (<54 mg/dL). RESEARCH DESIGN AND METHODS: In the GOLD randomized crossover trial, 161 individuals with type 1 diabetes treated with multiple daily insulin injections (MDI) were randomized to continuous glucose monitoring (CGM) or conventional therapy with self-monitoring of blood glucose (SMBG) and evaluated over 16 months. We estimated the association between time spent in hypoglycemia and various mean glucose and HbA1c levels. RESULTS: Time spent in hypoglycemia (<3.9 mmol/L and <3.0 mmol/L) increased significantly with lower mean HbA1c and mean glucose levels during both CGM and conventional therapy. During CGM, 24 (57.1%) individuals with HbA1c <7.5% (<58 mmol/mol) had <1.0% time spent in hypoglycemia <3.0 mmol/L and 23 (54.8%) had <4.0% time spent in hypoglycemia <3.9 mmol/L. During CGM, mean time spent in hypoglycemia for individuals with mean HbA1c 7.0% (52 mmol/mol) was estimated to be 5.4% for <3.9 mmol/L and 1.5% for <3.0 mmol/L. The corresponding values during SMBG were 9.2% and 3.5%, respectively. Individuals with mean glucose levels of 8 mmol/L spent 4.9% units more time with glucose levels <3.9 mmol/L and 2.8% units more time <3.0 mmol/L during SMBG compared with CGM. CONCLUSIONS: Reaching current targets for time in hypoglycemia while at the same time reaching HbA1c targets is challenging for patients with type 1 diabetes treated with MDI both with CGM and SMBG monitoring. However, CGM is associated with considerably less time in hypoglycemia than SMBG at a broad range of HbA1c levels and is crucial for patients with MDI treatment if they are to have a chance to approach hypoglycemia targets.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2337/dc19-2606

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Metadata

Authors
Seyed Ahmadi, S., Westman, K., Pivodic, A., Ólafsdóttir, A. F., Dahlqvist, S., Hirsch, I. B., Hellman, J., Ekelund, M., Heise, T., Polonsky, W., Wijkman, M., Schwarcz, E., & Lind, M.
Venue
Diabetes Care
Published
2020-07-08
Volume
43
Issue
9
Pages
2017-2024
ISSN
  • 0149-5992 (ISSN-L)
  • 1935-5548
OpenAlex
W3041249421
Cited by
51
References
9
FWCI
5.57
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.