CoChat

Improved time in range over 1 year is associated with reduced albuminuria in individuals with sensor-augmented insulin pump-treated type 1 diabetes

The DOI matches its Crossref record; 12 of the 13 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: To investigate the association between treatment-induced change in continuous glucose monitoring (CGM) time in range (TIR) and albuminuria in persons with type 1 diabetes (T1D) treated with sensor-augmented insulin pumps (SAP). RESEARCH DESIGN AND METHODS: Twenty-six out of 55 participants with albuminuria and multiple daily injection therapy (25% females; median 51 [interquartile range 46–63] years of age; glycated hemoglobin A1c (HbA1c) 75 [68–88] mmol/mol [9.0% (8.4–10.4%)]; and urinary albumin-to-creatinine ratio (UACR) 89 [37–250] mg/g) were in a randomized controlled trial assigned to SAP therapy for 1 year. Anthropometrics, CGM data, and blood and urine samples were collected every 3 months. RESULTS: Mean change (95% CI) in percentage of TIR (%TIR) was 13.2% (6.2; 20.2), in HbA1c was −14.4 (−17.4; −10.5) mmol/mol (−1.3% [−1.6; −1.0]), and in UACR was −15% (−38; 17) (all P < 0.05). UACR decreased by 19% (10; 28) per 10% increase in %TIR (P = 0.04), 18% (1; 30) per 10 mmol/mol decrease in HbA1c (P = 0.07), and 31% per 10-mmHg decrease in mean arterial pressure (P < 0.001). CONCLUSIONS: In this longitudinal study, treatment-induced increase in %TIR was significantly associated with decrease in albuminuria in T1D.

Overview

Integrity signals

Registry

Crossref · 10.2337/dc20-0909

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 12 references

Cited by

See all 72

Metadata

Authors
Ranjan, A. G., Rosenlund, S. V., Hansen, T. W., Rossing, P., Andersen, S., & Nørgaard, K.
Affiliations
  • Danish Diabetes Academy (DK)
  • Steno Diabetes Center Copenhagen (DK)
  • University of Copenhagen (DK)
Corresponding author
Ranjan, Ajenthen G.
Venue
Diabetes Care
Published
2020-09-04
Volume
43
Issue
11
Pages
2882-2885
ISSN
  • 0149-5992 (ISSN-L)
  • 1935-5548
OpenAlex
W3083350156
Cited by
72
References
13
Citations by year
2026: 7 · 2025: 6 · 2024: 8 · 2023: 13 · 2022: 17 · 2021: 20 · 2020: 1
FWCI
9.65
Type
journal article
Language
en
Open access
closed
Locations
  • Diabetes Care (publishedVersion)
  • PubMed (publishedVersion)
  • Research at the University of Copenhagen (University of Copenhagen) (submittedVersion)
Funders
  • Danish Diabetes Academy (PD002-19)
  • Danish Diabetes Association
Topics
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
  • Health Sciences › Medicine › Nephrology › Chronic Kidney Disease and Diabetes
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
Keywords
time in range, albuminuria, type 1 diabetes, sensor-augmented insulin pump therapy, continuous glucose monitoring, albumin-creatinine ratio, HbA1c, mean arterial pressure, glycemic control, diabetic nephropathy
MeSH terms
Serum Albumin, Human, Albuminuria, Blood Glucose, Creatinine, Diabetes Mellitus, Type 1, Female, Follow-Up Studies, Glycated Hemoglobin, Humans, Hypoglycemic Agents, Insulin, Insulin Infusion Systems, Longitudinal Studies, Male, Middle Aged, Time Factors, Blood Glucose Self-Monitoring, Treatment Outcome

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Improved time in range over 1 year is associated with reduced albuminuria in individuals with sensor-augmented insulin pump-treated type 1 diabetes. https://app.cochat.ai/papers/10.2337/dc20-0909
The paper
Ranjan, A. G., Rosenlund, S. V., Hansen, T. W., Rossing, P., Andersen, S., & Nørgaard, K. (2020). Improved time in range over 1 year is associated with reduced albuminuria in individuals with sensor-augmented insulin pump-treated type 1 diabetes. Diabetes Care. https://doi.org/10.2337/dc20-0909

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.