Cited by 131Diabetes Management and ResearchDiabetes Management and EducationDiabetes Treatment and Management

Optimal sampling intervals to assess long-term glycemic control using continuous glucose monitoring

Open access
Xing, Dongyuan, Kollman, Craig, Beck, Roy W., Tamborlane, William V., Laffel, Lori, Buckingham, Bruce A., Wilson, Darrell M., Weinzimer, Stuart +2 more·2011·Diabetes Technology & Therapeutics

Abstract

AIMS AND HYPOTHESIS: The optimal duration and frequency of short-term continuous glucose monitoring (CGM) to reflect long-term glycemia have not been determined. The Juvenile Diabetes Research Foundation CGM randomized trials provided a large dataset of longitudinal CGM data for this type of analysis. METHODS: The analysis included 185 subjects who had 334 3-month intervals of CGM data meeting specific criteria. For various glucose indices, correlations (r²) were computed for the entire 3-month interval versus selected sampling periods ranging from 3 to 15 days. Other computed agreement measures included median relative absolute difference, values within ± 10% and ± 20% of full value, and median absolute difference. RESULTS: As would be expected, the more days of glucose data that were sampled, the higher the correlation with the full 3 months of data. For 3 days of sampling, the r² value ranged from 0.32 to 0.47, evaluating mean glucose, percentage of values 71-180 mg/dL, percentage of values > 180 mg/dL, percentage of values ≤ 70 mg/dL, and coefficient of variation; in contrast, for 15 days of sampling, the r² values ranged from 0.66 to 0.75. The results were similar when the analysis intervals were stratified by age group (8-14, 15-24, and ≥ 25 years), by baseline hemoglobin A1c level (< 7.0% and ≥ 7.0%), and by CGM device type. CONCLUSIONS AND INTERPRETATION: Our data suggest that a 12-15-day period of monitoring every 3 months may be needed to optimally assess overall glucose control. Shorter periods of sampling can be useful, but the correlation with 3-month measures of glycemic control is lower.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/dia.2010.0156

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Correlations between CGM use and hypoglycemia/glycemic variability have not been shown to increase with longer sampling periods.

    “In individuals with type 1 diabetes, correlations are weaker for hypoglycemia and glycemic variability; however, these correlations have not been shown to increase with longer sampling periods (42).”

    From Clinical Targets for Continuous Glucose Monitoring Data Interpretation: Recommendations From the International Consensus on Time in Range (2019) · cites this paper as [42]

    The Results (Table 2; page unavailable) show that correlations with the full three-month data increased as sampling lengthened for both hypoglycemia and glycemic variability. From 3 to 15 days, r² rose from 0.32 to 0.66 for values ≤70 mg/dL and from 0.36 to 0.70 for coefficient of variation—the opposite of the attributed claim. (LLM, conf=0.93)

    Checked by a reasoning model — may be wrong.

    Experimental — accuracy not yet measured
  • In individuals with type 1 diabetes, correlations between >70% CGM use over 14 days and hypoglycemia and glycemic variability are weaker.

    “In individuals with type 1 diabetes, correlations are weaker for hypoglycemia and glycemic variability; however, these correlations have not been shown to increase with longer sampling periods (42).”

    From Clinical Targets for Continuous Glucose Monitoring Data Interpretation: Recommendations From the International Consensus on Time in Range (2019) · cites this paper as [42]

    In type 1 diabetes, the Results (Table 2; page unavailable) show weaker correlations for hypoglycemia and glycemic variability than for mean glucose at 15 days. But they also show that both correlations increase as sampling extends from 3 to 15 days, contrary to the citing sentence’s claim that an increase with longer sampling has not been shown. The paper does not frame this analysis as >70% CGM use over 14 days. (LLM, conf=0.88)

    Checked by a reasoning model — may be wrong.

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

1 of the 12 references couldn’t be matched to a known paper.

Research works printed but not linked: 3

  1. [1]Bugler J. An estimation of the amount of data required to measure glycemic variability. Presented at the Advanced Technologies and Treatment for Diabetes Conference; Prague, Czech Republic. 2008. [Google Scholar]
  2. [11]DexCom Inc. DexCom™ STS™ Continuous Glucose Monitoring System User's Guide. San Diego, CA: DexCom Inc.; 2006. pp. 86–102. [Google Scholar]
  3. [14]Magee L. R2 measures based on Wald and Likelihood Ratio Joint Significance tests. Am Stat. 1990;44:250–253. [Google Scholar]

Cited by

Sorted by citations

Authors
Xing, D., Kollman, C., Beck, R. W., Tamborlane, W. V., Laffel, L., Buckingham, B. A., Wilson, D. M., Weinzimer, S., Fiallo-Scharer, R., & Ruedy for the Juvenile Diabetes Research Foundation Continuo, K. J.
Affiliations
  • Jaeb Center for Health Research (US)
  • Yale University (US)
  • Joslin Diabetes Center (US)
  • Stanford University (US)
  • Barbara Davis Center
  • Jaeb Center for Health Research
Corresponding author
Xing, Dongyuan
Venue
Diabetes Technology & Therapeutics
Published
2011-03
Volume
13
Issue
3
Pages
351-358
ISSN
  • 1520-9156 (ISSN-L)
  • 1557-8593
OpenAlex
W2007986610
Cited by
131
References
12
Citations by year
2026: 10 · 2025: 7 · 2024: 11 · 2023: 15 · 2022: 18 · 2021: 21 · 2020: 15 · 2019: 10 · 2018: 4 · 2017: 6 · 2016: 4 · 2015: 1 · 2014: 1 · 2013: 1 · 2012: 5
FWCI
2.10
Type
journal article
Language
en
Open access
Locations
  • Diabetes Technology & Therapeutics (publishedVersion)
  • Europe PMC (PubMed Central) (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
Funders
Eunice Kennedy Shriver National Institute of Child Health and Human Development (U10HD041908)
Topics
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
Keywords
continuous glucose monitoring, glycemic control, sampling interval, HbA1c, mean blood glucose, hypoglycemia, hyperglycemia, coefficient of variation, type 1 diabetes
MeSH terms
Adolescent, Adult, Aged, Blood Glucose, Child, Diabetes Mellitus, Type 1, Female, Glycated Hemoglobin, Humans, Longitudinal Studies, Male, Middle Aged, Time Factors, Blood Glucose Self-Monitoring, Young Adult

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review