Fully Closed Loop Glucose Control With a Bihormonal Artificial Pancreas in Adults With Type 1 Diabetes: An Outpatient, Randomized, Crossover Trial
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To demonstrate the performance and safety of a bihormonal (insulin and glucagon) artificial pancreas (AP) in adults with type 1 diabetes. RESEARCH DESIGN AND METHODS: In this outpatient, randomized, crossover trial, 2-week fully closed loop glucose control (AP therapy) was compared with 2-week open loop control (patient’s normal insulin pump therapy with a glucose sensor if they had one). RESULTS: A total of 23 patients were included in the analysis. Time in range (70–180 mg/dL [3.9–10 mmol/L]) was significantly higher during closed loop (median 86.6% of time [interquartile range 84.9–88.5]) compared with open loop (53.9% [49.7–67.2]; P < 0.0001). CONCLUSIONS: Compared with insulin pump therapy, the bihormonal AP provided superior glucose control, without meal or exercise announcements, and was safe in adults with type 1 diabetes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Battelino, T., Danne, T., Bergenstal, R. M., Amiel, S. A., Beck, R., Biester, T., Bosi, E., Buckingham, B. A., Cefalu, W. T., Close, K. L., et al. (2019) · Diabetes Care · doi:10.2337/dci19-0028 · Cited by 4,237
Self-citationSix-Month Randomized, Multicenter Trial of Closed-Loop Control in Type 1 Diabetes
Brown, S. A., Kovatchev, B. P., Raghinaru, D., Lum, J. W., Buckingham, B. A., Kudva, Y. C., Laffel, L. M., Levy, C. J., Pinsker, J. E., Wadwa, R. P., et al. (2019) · New England Journal of Medicine · doi:10.1056/nejmoa1907863 · Cited by 1,030
Clarke, W. L., Cox, D. J., Gonder-Frederick, L. A., Julian, D., Schlundt, D., & Polonsky, W. (1995) · Diabetes Care · doi:10.2337/diacare.18.4.517 · Cited by 651
Safety of a hybrid closed-loop insulin delivery system in patients with type 1 diabetes
Bergenstal, R. M., Garg, S., Weinzimer, S. A., Buckingham, B. A., Bode, B. W., Tamborlane, W. V., & Kaufman, F. R. (2016) · JAMA · doi:10.1001/jama.2016.11708 · Cited by 644
Garg, S. K., Weinzimer, S. A., Tamborlane, W. V., Buckingham, B. A., Bode, B. W., Bailey, T. S., Brazg, R. L., Ilany, J., Slover, R. H., Anderson, S. M., et al. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2016.0421 · Cited by 585
Snoek, F. J., Pouwer, F., Welch, G. W., & Polonsky, W. H. (2000) · Diabetes Care · doi:10.2337/diacare.23.9.1305 · Cited by 444
Tauschmann, M., Thabit, H., Bally, L., Allen, J. M., Hartnell, S., Wilinska, M. E., Ruan, Y., Sibayan, J., Kollman, C., Cheng, P., et al. (2018) · The Lancet · doi:10.1016/s0140-6736(18)31947-0 · Cited by 440
Cited by
Phillip, M., Nimri, R., Bergenstal, R. M., Barnard-Kelly, K., Danne, T., Hovorka, R., Kovatchev, B. P., Messer, L. H., Parkin, C. G., Ambler-Osborn, L., et al. (2023) · Endocrine Reviews · doi:10.1210/endrev/bnac022 · Cited by 443
Self-citationSherr, J. L., Heinemann, L., Fleming, G. A., Bergenstal, R. M., Bruttomesso, D., Hanaire, H., Holl, R. W., Petrie, J. R., Peters, A. L., & Evans, M. (2022) · Diabetes Care · doi:10.2337/dci22-0018 · Cited by 136
“Yet, development of more suitable insulin products and algorithms with inclusion of meal detection and the ability to sense the glucose level every minute may allow for the eventual creation of a full AID system [29, 30].”
BackgroundElbalshy, M., Haszard, J., Smith, H., Kuroko, S., Galland, B., Oliver, N., Shah, V., de Bock, M. I., & Wheeler, B. J. (2022) · Diabetic Medicine · doi:10.1111/dme.14854 · Cited by 104
The role of automated insulin delivery technology in diabetes
Boughton, C. K., & Hovorka, R. (2024) · Diabetologia · doi:10.1007/s00125-024-06165-w · Cited by 57
“Dual hormone closed-loop systems using insulin and pram-lintide or insulin and glucagon have been evaluated in clinical trials but add complexity and cost, and are associated with gastrointestinal side effects [59, 60].”
BackgroundGarcia-Tirado, J., Diaz, J. L., Esquivel-Zuniga, R., Koravi, C. L. K., Corbett, J. P., Dawson, M., Wakeman, C., Barnett, C. L., Oliveri, M. C., Myers, H., et al. (2021) · Diabetes Care · doi:10.2337/dc21-0932 · Cited by 52
Metadata
- Authors
- Blauw, H., Onvlee, A. J., Klaassen, M., van Bon, A. C., & DeVries, J. H.
- Venue
- Diabetes Care
- Publisher
- American Diabetes Association
- Published
- 2021-01-04
- Volume
- 44
- Issue
- 3
- Pages
- 836-838
- ISSN
- 0149-5992 (ISSN-L)
- 1935-5548
- OpenAlex
- W3119784723
- Cited by
- 84
- References
- 7
- FWCI
- 9.35
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.