Fast-Acting Insulin Aspart Versus Insulin Aspart Using a Second-Generation Hybrid Closed-Loop System in Adults With Type 1 Diabetes: A Randomized, Open-Label, Crossover Trial
Open accessThe DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To evaluate glucose control using fast-acting insulin aspart (faster aspart) compared with insulin aspart (IAsp) delivered by the MiniMed Advanced Hybrid Closed-Loop (AHCL) system in adults with type 1 diabetes. RESEARCH DESIGN AND METHODS: In this randomized, open-label, crossover study, participants were assigned to receive faster aspart or IAsp in random order. Stages 1 and 2 comprised of 6 weeks in closed loop, preceded by 2 weeks in open loop. This was followed by stage 3, whereby participants changed directly back to the insulin formulation used in stage 1 for 1 week in closed loop. Participants chose their own meals except for two standardized meal tests, a missed meal bolus and late meal bolus. The primary outcome was the percentage of time sensor glucose values were from 70 to 180 mg/dL (time in range [TIR]). RESULTS: Twenty-five adults (52% male) were recruited; the median (interquartile range) age was 48 (37, 57) years, and the median HbA1c was 7.0% (6.6, 7.2) (53 [49, 55] mmol/mol). Faster aspart demonstrated greater overall TIR compared with IAsp (82.3% [78.5, 83.7] vs. 79.6% [77.0, 83.4], respectively; mean difference 1.9% [0.5, 3.3]; P = 0.007). Four-hour postprandial glucose TIR was higher using faster aspart compared with IAsp for all meals combined (73.6% [69.4, 80.2] vs. 72.1% [64.5, 78.5], respectively; median difference 3.5% [1.0, 7.3]; P = 0.003). There was no ketoacidosis or severe hypoglycemia. CONCLUSIONS: Faster aspart safely improved glucose control compared with IAsp in a group of adults with well-controlled type 1 diabetes using AHCL. The modest improvement was mainly related to mealtime glycemia. While the primary outcome demonstrated statistical significance, the clinical impact may be small, given an overall difference in TIR of 1.9%.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Battelino, T., Danne, T., Bergenstal, R. M., Amiel, S. A., Beck, R., Biester, T., Bosi, E., Buckingham, B. A., Cefalu, W. T., Close, K. L., et al. (2019) · Diabetes Care · doi:10.2337/dci19-0028 · Cited by 4,237
State of Type 1 Diabetes Management and Outcomes from the T1D Exchange in 2016–2018
Foster, N. C., Beck, R. W., Miller, K. M., Clements, M. A., Rickels, M. R., DiMeglio, L. A., Maahs, D. M., Tamborlane, W. V., Bergenstal, R., Smith, E., et al. (2019) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2018.0384 · Cited by 1,907
International Hypoglycaemia Study Group (2017) · Diabetes Care · doi:10.2337/dc16-2215 · Cited by 608
Weisman, A., Bai, J.-W., Cardinez, M., Kramer, C. K., & Perkins, B. A. (2017) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(17)30167-5 · Cited by 463
Bekiari, E., Kitsios, K., Thabit, H., Tauschmann, M., Athanasiadou, E., Karagiannis, T., Haidich, A.-B., Hovorka, R., & Tsapas, A. (2018) · BMJ · doi:10.1136/bmj.k1310 · Cited by 437
Bergenstal, R. M., Nimri, R., Beck, R. W., Criego, A., Laffel, L., Schatz, D., Battelino, T., Danne, T., Weinzimer, S. A., Sibayan, J., et al. (2021) · The Lancet · doi:10.1016/s0140-6736(20)32514-9 · Cited by 344
Collyns, O. J., Meier, R. A., Betts, Z. L., Chan, D. S. H., Frampton, C., Frewen, C. M., Hewapathirana, N. M., Jones, S. D., Roy, A., Grosman, B., et al. (2021) · Diabetes Care · doi:10.2337/dc20-2250 · Cited by 276
Self-citationMudaliar, S. R., Lindberg, F. A., Joyce, M., Beerdsen, P., Strange, P., Lin, A., & Henry, R. R. (1999) · Diabetes Care · doi:10.2337/diacare.22.9.1501 · Cited by 276
Heise, T., Pieber, T. R., Danne, T., Erichsen, L., & Haahr, H. (2017) · Clinical Pharmacokinetics · doi:10.1007/s40262-017-0514-8 · Cited by 182
Optimal prandial timing of bolus insulin in diabetes management: a review
Slattery, D., Amiel, S. A., & Choudhary, P. (2018) · Diabetic Medicine · doi:10.1111/dme.13525 · Cited by 132
Cited by
The role of automated insulin delivery technology in diabetes
Boughton, C. K., & Hovorka, R. (2024) · Diabetologia · doi:10.1007/s00125-024-06165-w · Cited by 57
Bionic Pancreas Research Group, Beck, R. W., Russell, S. J., Damiano, E. R., El-Khatib, F. H., Ruedy, K. J., Balliro, C., Li, Z., & Calhoun, P. (2022) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2022.0167 · Cited by 40
Shah, V. N., Peters, A. L., Umpierrez, G. E., Sherr, J. L., Akturk, H. K., Aleppo, G., Bally, L., Cengiz, E., Cinar, A., Dungan, K., et al. (2025) · Journal of Diabetes Science and Technology · doi:10.1177/19322968241291512 · Cited by 36
Metadata
- Authors
- Lee, M. H., Paldus, B., Vogrin, S., Morrison, D., Zaharieva, D. P., Lu, J., Jones, H. M., Netzer, E., Robinson, L., Grosman, B., Roy, A., Kurtz, N., Ward, G. M., MacIsaac, R. J., Jenkins, A. J., & O’Neal, D. N.
- Venue
- Diabetes Care
- Publisher
- American Diabetes Association
- Published
- 2021-08-06
- Volume
- 44
- Issue
- 10
- Pages
- 2371-2378
- ISSN
- 0149-5992 (ISSN-L)
- 1935-5548
- OpenAlex
- W3187785889
- Cited by
- 37
- References
- 11
- FWCI
- 4.36
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.