Cited by 86Diabetes Management and ResearchDiabetes Management and EducationDiabetes Treatment and Management

Universal Subsidized Continuous Glucose Monitoring Funding for Young People With Type 1 Diabetes: Uptake and Outcomes Over 2 Years, a Population-Based Study

Open access
Johnson, Stephanie R., Holmes-Walker, Deborah J., Chee, Melissa, Earnest, Arul, Jones, Timothy W.·2022·Diabetes Care

Published version of a preprint

Abstract

OBJECTIVE: Continuous glucose monitoring (CGM) is increasingly used in type 1 diabetes management; however, funding models vary. This study determined the uptake rate and glycemic outcomes following a change in national health policy to introduce universal subsidized CGM funding for people with type 1 diabetes aged <21 years. RESEARCH DESIGN AND METHODS: Longitudinal data from 12 months before the subsidy until 24 months after were analyzed. Measures and outcomes included age, diabetes duration, HbA1c, episodes of diabetic ketoacidosis and severe hypoglycemia, insulin regimen, CGM uptake, and percentage CGM use. Two data sources were used: the Australasian Diabetes Database Network (ADDN) registry (a prospective diabetes database) and the National Diabetes Service Scheme (NDSS) registry that includes almost all individuals with type 1 diabetes nationally. RESULTS: CGM uptake increased from 5% presubsidy to 79% after 2 years. After CGM introduction, the odds ratio (OR) of achieving the HbA1c target of <7.0% improved at 12 months (OR 2.5, P < 0.001) and was maintained at 24 months (OR 2.3, P < 0.001). The OR for suboptimal glycemic control (HbA1c ≥9.0%) decreased to 0.34 (P < 0.001) at 24 months. Of CGM users, 65% used CGM >75% of time, and had a lower HbA1c at 24 months compared with those with usage <25% (7.8 ± 1.3% vs. 8.6 ± 1.8%, respectively, P < 0.001). Diabetic ketoacidosis was also reduced in this group (incidence rate ratio 0.49, 95% CI 0.33–0.74, P < 0.001). CONCLUSIONS: Following the national subsidy, CGM use was high and associated with sustained improvement in glycemic control. This information will inform economic analyses and future policy and serve as a model of evaluation diabetes technologies.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2337/dc21-1666

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 13

  1. Phelan H, Clapin H, Bruns L, et al. The Australasian Diabetes Data Network: first national audit of children and adolescents with type 1 diabetes. Med J Aust 2017;206:121-125
  2. Foster NC, Beck RW, Miller KM, et al. State of type 1 diabetes management and outcomes from the T1D Exchange in 2016-2018. Diabetes Technol Ther 2019;21:66-72
  3. Laffel LM, Kanapka LG, Beck RW, et al.; CGM Intervention in Teens and Young Adults with T1D (CITY) Study Group; CDE10. Effect of continuous glucose monitoring on glycemic control in adol- escents and young adults with type 1 diabetes: a randomized clinical trial. JAMA 2020;323: 2388-2396
  4. Miller KM, Hermann J, Foster N, et al.; T1D Exchange and DPV Registries. Longitudinal changes in continuous glucose monitoring use among individuals with type 1 diabetes: international comparison in the German and Austrian DPV and U.S. T1D Exchange registries. Diabetes Care 2020;43:e1-e2
  5. Lipman TH, Hawkes CP. Racial and socioeconomic disparities in pediatric type 1 diabetes: time for a paradigm shift in approach. Diabetes Care 2021;44:14-16
  6. Addala A, Auzanneau M, Miller K, et al. A decade of disparities in diabetes technology use and HbA1c in pediatric type 1 diabetes: a transatlantic comparison. Diabetes Care 2021;44:133-140
  7. Lai CW, Lipman TH, Willi SM, Hawkes CP. Racial and ethnic disparities in rates of continuous glucose monitor initiation and continued use in children with type 1 diabetes. Diabetes Care 2021;44:255-257
  8. Nørgaard K, Schmidt S. Is reimbursement for alerts and real-time continuous glucose moni- toring needed? Lancet 2021;397:2230-2232
  9. Clapin H, Phelan H, Bruns L Jr, et al.; Australasian Diabetes Data Network (ADDN) Study Group. Australasian Diabetes Data Network: building a collaborative resource. J Diabetes Sci Technol 2016;10:1015-1026
  10. Thabit H, Prabhu JN, Mubita W, et al. Use of factory-calibrated real-time continuous glucose monitoring improves time in target and HbA 1c in a multiethnic cohort of adolescents and young adults with type 1 diabetes: the MILLENNIALS Study. Diabetes Care 2020;43:2537-2543
  11. Battelino T, Phillip M, Bratina N, Nimri R, Oskarsson P, Bolinder J. Effect of continuous glucose monitoring on hypoglycemia in type 1 diabetes. Diabetes Care 2011;34:795-800
  12. Cherubini V, Bonfanti R, Casertano A, et al. Time in range in children with type 1 diabetes using treatment strategies based on non- automated insulin delivery systems in the real world. Diabetes Technol Ther 2020;22:509-515
  13. Wong JC, Foster NC, Maahs DM, et al.; T1D Exchange Clinic Network. Real-time continuous glucose monitoring among participants in the T1D Exchange clinic registry. Diabetes Care 2014;37:2702-2709

Cited by

Sorted by citations

Authors
Johnson, S. R., Holmes-Walker, D. J., Chee, M., Earnest, A., & Jones, T. W.
Affiliations
  • The University of Queensland (AU)
  • The University of Sydney (AU)
  • Juvenile Diabetes Research Foundation (AU)
  • Monash University (AU)
  • The Kids Research Institute Australia (AU)
Corresponding author
Jones, Timothy W.
Venue
Diabetes Care
Published
2021-12-06
Volume
45
Issue
2
Pages
391-397
ISSN
0149-5992 (ISSN-L)
OpenAlex
W4200450426
Cited by
86
References
6
Citations by year
2026: 13 · 2025: 16 · 2024: 27 · 2023: 18 · 2022: 12
FWCI
10.64
Type
journal article
Language
en
Open access
Locations
  • Diabetes Care (publishedVersion)
  • PubMed Central (publishedVersion)
  • Bond University Research Portal (Bond University) (publishedVersion, other-oa)
  • UWA Profiles and Research Repository (UWA) (publishedVersion, cc-by-nc-nd)
  • PubMed (publishedVersion)
  • Adelaide Research & Scholarship (AR&S) (University of Adelaide) (submittedVersion)
Funders
  • Juvenile Diabetes Research Foundation Australia
  • Australian Research Council
Topics
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
Keywords
continuous glucose monitoring, type 1 diabetes, health policy, glycemic control, HbA1c, diabetic ketoacidosis, severe hypoglycemia, young adults, technology adoption
MeSH terms
Adolescent, Adult, Blood Glucose, Diabetes Mellitus, Type 1, Glycated Hemoglobin, Humans, Hypoglycemic Agents, Insulin, Prospective Studies, Blood Glucose Self-Monitoring, Young Adult

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review