7. Diabetes Technology: Standards of Medical Care in Diabetes—2021
The DOI matches its Crossref record; 206 of the 207 references it cites were found in a registry or an index.
Abstract
The American Diabetes Association (ADA) "Standards of Medical Care in Diabetes" includes the ADA's current clinical practice recommendations and is intended to provide the components of diabetes care, general treatment goals and guidelines, and tools to evaluate quality of care. Members of the ADA Professional Practice Committee, a multidisciplinary expert committee (https://doi.org/10.2337/dc21-SPPC), are responsible for updating the Standards of Care annually, or more frequently as warranted. For a detailed description of ADA standards, statements, and reports, as well as the evidence-grading system for ADA's clinical practice recommendations, please refer to the Standards of Care Introduction (https://doi.org/10.2337/dc21-SINT). Readers who wish to comment on the Standards of Care are invited to do so at professional.diabetes.org/SOC.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Although results provided by microdialysis are sufficiently precise, this technique is not yet commonly used due to the high costs of the instrumentation. Furthermore, the instruments are bulky and cannot be worn during daily activities 108.”
From Glucose biosensors in clinical practice: principles, limits and perspectives of currently used devices (2022) · cites this paper as [108]
In the citing paper
“devices for SMBG have not consistently shown a significant reduction in HbA1c in noninsulin treated patients with type 2 diabetes.”
From Glucose biosensors in clinical practice: principles, limits and perspectives of currently used devices (2022) · cites this paper as [108]
In the citing paper
“While devices for both SMBG and CGM have shown to be useful tools in type 1 diabetes with HbA1c and hypoglycemia as primary outcomes 108”
From Glucose biosensors in clinical practice: principles, limits and perspectives of currently used devices (2022) · cites this paper as [108]
In the citing paper
“On the other hand, in type 2 diabetes under insulin and/or hypoglycemic oral treatment, the use of a CGM device reduces HbA1c, but not the rates of hypoglycemia 108”
From Glucose biosensors in clinical practice: principles, limits and perspectives of currently used devices (2022) · cites this paper as [108]
In the citing paper
“while in gestational diabetes these devices help to achieve a better daytime glucose profile, providing an improvement in both maternal and neonatal outcomes 108, 181.”
From Glucose biosensors in clinical practice: principles, limits and perspectives of currently used devices (2022) · cites this paper as [108]
1 more claim about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Items 201–206 of 206
Flash glucose monitoring in type 1 diabetes: A comparison with self‐monitoring blood glucose
Babaya, N., Noso, S., Hiromine, Y., Taketomo, Y., Niwano, F., Yoshida, S., Yasutake, S., Kawabata, Y., & Ikegami, H. (2020) · Journal of Diabetes Investigation · doi:10.1111/jdi.13229 · Cited by 15 · cited 1×
“In many cases, isCGM is the preferred alternative compared with SMBG (85,86).”
Raval, A. D., Nguyen, M. H., Zhou, S., Grabner, M., Barron, J. O., & Quimbo, R. A. (2019) · Journal of Managed Care & Specialty Pharmacy · doi:10.18553/jmcp.2019.25.10.1111 · Cited by 13
Harrison, B., & Brown, D. (2020) · Expert Review of Medical Devices · doi:10.1080/17434440.2020.1704253 · Cited by 12 · cited 1×
“may also be beneficial to patients (6) and may make SMBG less burdensome for patients to perform.”
BackgroundFlash Glucose Monitoring System for Diabetes
Palylyk-Colwell, E., & Ford, C. (2018) · Europe PMC (PubMed Central) · Cited by 12
Gill, M., Chhabra, H., Shah, M., Zhu, C., & Grunberger, G. (2018) · Endocrine Practice · doi:10.4158/ep-2017-0220 · Cited by 8 · cited 1×
“There are no data to suggest that measurement of C-peptide levels or antibodies predicts success with insulin pump therapy (129,130).”
BackgroundRaval, A. D., Nguyen, M. H., Zhou, S., Grabner, M., Barron, J., & Quimbo, R. (2019) · Journal of Managed Care & Specialty Pharmacy · doi:10.18553/jmcp.2019.18438 · Cited by 8 · cited 1×
“Another pump option in people with type 2 diabetes is a disposable patchlike device, which provides a continuous, subcutaneous infusion of rapid-acting insulin (basal) as well as 2-unit increments of bolus insulin at the press of a button (153,155,158).”
Background
Cited by
Holt, R. I. G., DeVries, J. H., Hess-Fischl, A., Hirsch, I. B., Kirkman, M. S., Klupa, T., Ludwig, B., Nørgaard, K., Pettus, J., Renard, E., et al. (2021) · Diabetes Care · doi:10.2337/dci21-0043 · Cited by 699
Holt, R. I. G., DeVries, J. H., Hess-Fischl, A., Hirsch, I. B., Kirkman, M. S., Klupa, T., Ludwig, B., Nørgaard, K., Pettus, J., Renard, E., et al. (2021) · Diabetologia · doi:10.1007/s00125-021-05568-3 · Cited by 378
Management of diabetes and hyperglycaemia in the hospital
Pasquel, F. J., Lansang, M. C., Dhatariya, K., & Umpierrez, G. E. (2021) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(20)30381-8 · Cited by 329
Pullano, S. A., Greco, M., Bianco, M. G., Foti, D., Brunetti, A., & Fiorillo, A. S. (2022) · Theranostics · doi:10.7150/thno.64035 · Cited by 210
Karter, A. J., Parker, M. M., Moffet, H. H., Gilliam, L. K., & Dlott, R. (2021) · JAMA · doi:10.1001/jama.2021.6530 · Cited by 191
Metadata
- Authors
- American Diabetes Association
- Venue
- Diabetes Care
- Publisher
- American Diabetes Association
- Published
- 2020-12-04
- Volume
- 44
- Issue
- Supplement_1
- Pages
- S85-S99
- ISSN
- 0149-5992 (ISSN-L)
- 1935-5548
- OpenAlex
- W4233732280
- Cited by
- 202
- References
- 207
- Citations by year
- 2026: 3 · 2025: 11 · 2024: 15 · 2023: 39 · 2022: 66 · 2021: 68
- FWCI
- 6.63
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Diabetes Care (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Keywords
- diabetes technology, clinical guidelines, quality of care, treatment goals, level of evidence
- MeSH terms
- Diabetes Mellitus, Endocrinology, Humans, Reference Standards, Societies, Medical, Standard of Care
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.