Accuracy of a blood glucose monitoring system that recognizes insufficient sample blood volume and allows application of more blood to the same test strip

Harrison, Bern, Brown, Daniel · 2020 · Expert Review of Medical Devices

The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.

Abstract

Background: Self-monitoring of blood glucose (SMBG) can play a key role in diabetes management. The CONTOUR®NEXT ONE (Ascensia Diabetes Care, Parsippany, NJ, USA) blood glucose monitoring system (BGMS) has been developed for use with CONTOUR®NEXT test strips. The meter connects to the CONTOUR™ Diabetes application on a mobile device, and the Second-Chance® sampling feature recognizes insufficient sample volume, prompting the patient to apply more blood to the same strip if needed (sample re-application).Research design and methods: Two studies evaluated CONTOUR®NEXT ONE BGMS accuracy with sample re-application: a laboratory study (performance under various controlled conditions) and a clinical study (performance in the hands of 52 people with diabetes). A formal International Organization for Standardization (ISO) evaluation has been reported previously; here, accuracy criteria in the laboratory and clinical studies were aligned with ISO 15197:2013 sections 6.3.3 and 8.2, respectively.Results: All results under all conditions in the laboratory study, and with glucose concentrations <100 and ≥100 mg/dL in the clinical study, were within ±15 mg/dL or ±15% of reference measurements. In both studies, all results were within Zone A of the Parkes-Consensus Error Grid.Conclusions: These data demonstrate that the accuracy of the CONTOUR®NEXT ONE BGMS was maintained with sample re-application.

Overview

Integrity signals

Registry

Crossref · 10.1080/17434440.2020.1704253

Cites

18 of 18 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 18 references

Cited by

See all 13

Metadata

Authors
Harrison, B., & Brown, D.
Affiliations
Sensor Technology, Ascensia Diabetes Care, Valhalla, NY, USA
Corresponding author
Brown, Daniel
Venue
Expert Review of Medical Devices
Published
2020-01-02
Volume
17
Issue
1
Pages
75-82
ISSN
  • 1743-4440 (ISSN-L)
  • 1745-2422
OpenAlex
W2994924405
Cited by
12
References
18
Citations by year
2025: 1 · 2024: 2 · 2023: 2 · 2022: 2 · 2021: 2 · 2020: 3
FWCI
1.42
Type
journal article
Language
en
Open access
closed
Locations
  • Expert Review of Medical Devices (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
  • Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
Keywords
self-monitoring of blood glucose, blood glucose meter accuracy, diabetes management, ISO 15197
MeSH terms
Blood Glucose, Blood Specimen Collection, Blood Volume, Diabetes Mellitus, Humans, Regression Analysis, Blood Glucose Self-Monitoring, Reproducibility of Results

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Accuracy of a blood glucose monitoring system that recognizes insufficient sample blood volume and allows application of more blood to the same test strip. https://app.cochat.ai/papers/10.1080/17434440.2020.1704253
The paper
Harrison, B., & Brown, D. (2020). Accuracy of a blood glucose monitoring system that recognizes insufficient sample blood volume and allows application of more blood to the same test strip. Expert Review of Medical Devices. https://doi.org/10.1080/17434440.2020.1704253

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.