Ambulatory Blood Pressure Monitoring in the Diagnosis and Management of Hypertension
Open accessThe DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
Although blood pressure (BP) is a frequently used variable in nursing studies, measurements are likely to be inaccurate for a variety of reasons: incorrect technique, operator error, and environmental factors. Ambulatory BP monitoring (ABPM) reduces measurement error, is relatively easy to use, and yields many more BP parameters than do clinic BP measurements. The cost of equipment for ABPM ranges from $2,500 to $5,000 per monitor and from $2,000 to $3,000 for computer software. A research assistant can easily be trained to follow a standardized procedure. Researchers have used ABPM to study normal BP patterns, complications of hypertension, effects of antihypertensive drugs, and the prognosis of cardiovascular events. This article provides the nurse researcher with an introduction to this technology and an overview of information gained from ambulatory blood pressure monitoring.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Staessen, J. A. (1999) · JAMA · doi:10.1001/jama.282.6.539 · Cited by 1,592
Kario, K., Pickering, T. G., Umeda, Y., Hoshide, S., Hoshide, Y., Morinari, M., Murata, M., Kuroda, T., Schwartz, J. E., & Shimada, K. (2003) · Circulation · doi:10.1161/01.cir.0000056521.67546.aa · Cited by 1,250
Overconfidence as a Cause of Diagnostic Error in Medicine
Berner, E. S., & Graber, M. L. (2008) · The American Journal of Medicine · doi:10.1016/j.amjmed.2008.01.001 · Cited by 1,034
Rothwell, P. M., Howard, S. C., Dolan, E., O'Brien, E., Dobson, J. E., Dahlöf, B., Poulter, N. R., & Sever, P. S. (2010) · The Lancet Neurology · doi:10.1016/s1474-4422(10)70066-1 · Cited by 690
European Society of Hypertension Practice Guidelines for home blood pressure monitoring
Parati, G., Stergiou, G. S., Asmar, R., Bilo, G., de Leeuw, P., Imai, Y., Kario, K., Lurbe, E., Manolis, A., Mengden, T., et al. (2010) · Journal of Human Hypertension · doi:10.1038/jhh.2010.54 · Cited by 482
Niiranen, T. J., Hänninen, M.-R., Johansson, J., Reunanen, A., & Jula, A. M. (2010) · Hypertension · doi:10.1161/hypertensionaha.109.149336 · Cited by 390
Hodgkinson, J., Mant, J., Martin, U., Guo, B., Hobbs, F. D. R., Deeks, J. J., Heneghan, C., Roberts, N., & McManus, R. J. (2011) · BMJ · doi:10.1136/bmj.d3621 · Cited by 370 · cited 1×
“test for diagnosing HTN in adults (12).”
Ben-Dov, I. Z., Kark, J. D., Ben-Ishay, D., Mekler, J., Ben-Arie, L., & Bursztyn, M. (2007) · Hypertension · doi:10.1161/hypertensionaha.107.087262 · Cited by 367
Ambulatory Blood Pressure and Mortality: A Population-Based Study
Hansen, T. W., Jeppesen, J., Rasmussen, S., Ibsen, H., & Torp-Pedersen, C. (2005) · Hypertension · doi:10.1161/01.hyp.0000160402.39597.3b · Cited by 317 · cited 1×
“Several studies that compared ABPM with intra-arterial measurements and mercury column sphygmomanometers demonstrated the accuracy of ABPM (7).”
Lovibond, K., Jowett, S., Barton, P., Caulfield, M., Heneghan, C., Hobbs, F. R., Hodgkinson, J., Mant, J., Martin, U., Williams, B., et al. (2011) · The Lancet · doi:10.1016/s0140-6736(11)61184-7 · Cited by 311
Cited by
Parati, G., Kjeldsen, S., Coca, A., Cushman, W. C., & Wang, J. (2021) · Hypertension · doi:10.1161/hypertensionaha.120.15781 · Cited by 281
Argano, C., Mirarchi, L., Amodeo, S., Orlando, V., Torres, A., & Corrao, S. (2023) · International Journal of Molecular Sciences · doi:10.3390/ijms242015485 · Cited by 204
“Observational and experimental data favor the concept that vitamin D is associated with the pathogen-Int esis of arterial hypertension [224,225].”
BackgroundKario, K., Shin, J., Chen, C., Buranakitjaroen, P., Chia, Y., Divinagracia, R., Nailes, J., Hoshide, S., Siddique, S., Sison, J., et al. (2019) · The Journal of Clinical Hypertension · doi:10.1111/jch.13652 · Cited by 164
Paula, T. P., Viana, L. V., Neto, A. T. Z., Leitão, C. B., Gross, J. L., & Azevedo, M. J. (2015) · The Journal of Clinical Hypertension · doi:10.1111/jch.12597 · Cited by 115
“An office BP reduction associated with a pedometer-based walking program (increment of 1562 steps per day) has already been described in patients with type 2 diabetes.30 Indeed, a recent meta-analysis of randomized controlled trials demonstrated that physical activity advice reduces systolic and diastolic BP in type 2…”
BackgroundInfluential2020 Consensus summary on the management of hypertension in Asia from the HOPE Asia Network
Kario, K., Park, S., Chia, Y., Sukonthasarn, A., Turana, Y., Shin, J., Chen, C., Buranakitjaroen, P., Divinagracia, R., Nailes, J., et al. (2020) · The Journal of Clinical Hypertension · doi:10.1111/jch.13751 · Cited by 76
Metadata
- Authors
- Grossman, E.
- Venue
- Diabetes Care
- Publisher
- American Diabetes Association
- Published
- 2013-07-17
- Volume
- 36
- Issue
- Supplement_2
- Pages
- S307-S311
- ISSN
- 0149-5992 (ISSN-L)
- 1935-5548
- OpenAlex
- W2153134155
- Cited by
- 141
- References
- 14
- FWCI
- 4.45
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ambulatory Blood Pressure Monitoring in the Diagnosis and Management of Hypertension. https://app.cochat.ai/papers/10.2337/dcs13-2039
- The paper
- Grossman, E. (2013). Ambulatory Blood Pressure Monitoring in the Diagnosis and Management of Hypertension. Diabetes Care. https://doi.org/10.2337/dcs13-2039
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.