The DOI matches its Crossref record.
A high‐performance liquid chromatography method for hemoglobin A1c
Abstract
Hemoglobin A1c (HbA1c) is a glycosylated derivative of hemoglobin and is one of a family of derivatives whose concentrations are elevated in patients with diabetes mellitus. Published methods for the measurement of HbA1c are relatively tedious and require modest amounts of blood. A high-performance liquid chromatographic (HPLC) method for the determination of HbA1c is presented. The method is rapid (20 minutes), precise (coefficient of variation of 5-10 per cent), uses small amounts of sample (3 microliter.), can be automated. A sample preparation technique using filtration was developed that shortened and simplified preparation of venous blood and allowed use of capillary samples. HbA1c was measured by this method in three age-stratified groups of controls and a group of insulin-requiring juvenile diabetics. There was clear separation of HbA1c values between all normals (5.9 +/- 1.3, 5.6 +/- 0.7, 7.1 +/- 0.9 per cent) and the diabetics (12.1 +/- 2.4 per cent). Use of this method can facilitate large-scale clinical investigations and permit biochemical investigations of the metabolism and formation of hemoglobin A1c where small sample sizes are necessary.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The coefficient of variation of this reference method was < 3%.”
From Twenty‐four‐hour profiles of plasma glucose, insulin, C‐peptide and free fatty acid in subjects with varying degrees of glucose tolerance following short‐term, medium‐dose prednisone (20 mg/day) treatment: evidence for differing effects on insulin secretion and action (2012) · cites this paper as [19]
Citations
Cited by
Sorted by citations
Items 101–192 of 192
Acarbose treatment of non-insulin-dependent diabetes mellitus.
Lardinois, C. K., Greenfield, M. S., Schwartz, H. C., Vreman, H. J., & Reaven, G. M. (1984) · PubMed · Cited by 21
Baba, T., Murabayashi, S., Tomiyama, T., et al. (1990) · The Tohoku Journal of Experimental Medicine · doi:10.1620/tjem.161.311 · Cited by 21
Measurement of glycosylated hemoglobins using boronate affinity chromatography.
Herold, D. A., Boyd, J. C., Bruns, D. E., et al. (1984) · PubMed · Cited by 20
Pang, C., Jia, L., Hou, X., Gao, X., Liu, W., Bao, Y., & Jia, W. (2014) · PLoS ONE · doi:10.1371/journal.pone.0097928 · Cited by 20
Baba, T., Tomiyama, T., Murabayashi, S., & Takebe, K. (1990) · European Journal of Clinical Pharmacology · doi:10.1007/bf02336678 · Cited by 20
“performance liquid chromatography [ 21 ] on a cation-exchange minicolumn (Auto AI0 HA-8110, Kyoto Daiichi Kagaku, Kyoto, Japan).”
MethodInfluence of Iron Deficiency on HbA1c Levels in Pregnant Women: Comparison with Non-Pregnant Women
Hashimoto, K., & Koga, M. (2018) · Journal of Clinical Medicine · doi:10.3390/jcm7020034 · Cited by 19
Patti, L., Romanò, G., Marino, L., Annuzzi, G., Mancini, M., Riccardi, G., & Rivellese, A. A. (1993) · Diabetologia · doi:10.1007/bf00400698 · Cited by 18
“HbAic was measured by high pressure liquid chromatography [ 27 ]; normal values in our laboratory are less than 6,7 %.”
MethodGrylls, W. K., McKenzie, J. E., Horwath, C. C., & Mann, J. I. (2003) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1601700 · Cited by 17
“(Davis et al, 1978).”
Best use of the recommended IFCC reference method, material and values in HbA1Canalyses
Penttilä, I., Halonen, T., Punnonen, K. R. A., & Tiikkainen, U. (2005) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365510510025809 · Cited by 17
Renal kallikrein in diabetic patients with hypertension accompanied by nephropathy
Baba, T., Murabayashi, S., Ishizaki, T., et al. (1986) · Diabetologia · doi:10.1007/bf02427087 · Cited by 17
“Glycosylated haemoglobin Aac was measured by high-performance liquid chromatography [ 19 ] on a cation-exchange minieolumn (Auto Ale HA-8110, Kyoto Daiichi Kagaku, Kyoto, Japan) (intrassay CV, 2.2%).”
MethodInfluentialHemoglobin osler: Report of a new family with exercise studies before and after phlebotomy
Butler, W. M., Spratling, L., Kark, J. A., et al. (1982) · American Journal of Hematology · doi:10.1002/ajh.2830130404 · Cited by 16
Metabolic Profile of Breast Cancer in a Population of Women in Southern Spain
López‐Sáez, J. B., Martinez-Rubio, J. A., Alvarez, M. M., et al. (2008) · The Open Clinical Cancer Journal · doi:10.2174/1874189400802010001 · Cited by 16
Sequential vitreous fluorophotometry in diabetes mellitus: a five-year prospective study.
Waltman, S. R. (1984) · PubMed · Cited by 16
Heo, G. Y., Koh, H. B., Kim, H. W., Park, J. T., Yoo, T., Kang, S., Kim, J., Kim, S. W., Kim, Y. H., Sung, S. A., et al. (2023) · Diabetes & Metabolism Journal · doi:10.4093/dmj.2022.0112 · Cited by 15
“Although HPLC is expensive and requires regular maintenance, it is a rapid, automated, and highly precise method, that delivers high resolution compared to other techniques [36].”
MethodPatti, L., Marino, L., Maffettone, A., Romanò, G., Annuzzi, G., Riccardi, G., & Rivellese, A. A. (1995) · Diabetologia · doi:10.1007/bf00400602 · Cited by 15
Cation-exchange, high-performance liquid chromatographic determination of hemoglobin A1c.
Toren, E. C., Vacik, D. N., & Mockridge, P. B. (1983) · Journal of Chromatography A · doi:10.1016/s0021-9673(01)90894-5 · Cited by 14
Grewal, R., Ortega, G. A., Geng, F., Srinivasan, S., & Rajabzadeh, A. R. (2024) · Bioelectrochemistry · doi:10.1016/j.bioelechem.2024.108743 · Cited by 14
Bone mass and bone resorption in postmenopausal women with type 2 diabetes mellitus
Hosoda, H., Fukui, M., Nakayama, I., Asano, M., Kadono, M., Hasegawa, G., Yoshikawa, T., & Nakamura, N. (2008) · Metabolism · doi:10.1016/j.metabol.2008.02.009 · Cited by 13
Petruzzi, E., Orlando, C., Pinzani, P., et al. (1994) · Metabolism · doi:10.1016/0026-0495(94)90072-8 · Cited by 13
Plasma Epinephrine Disturbances in Diabetic Subjects during Standing and after Isometric Exercise*
Gustafson, A. B., & Kalkhoff, R. K. (1981) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem-53-4-759 · Cited by 13
Lübec, G., Legenstein, E., Pollak, A. J., et al. (1980) · Clinica Chimica Acta · doi:10.1016/0009-8981(80)90229-6 · Cited by 13
Comparison of single- and split-dose insulin regimens with 24-hour monitoring
Langdon, D. R., James, F. D., & Sperling, M. A. (1981) · The Journal of Pediatrics · doi:10.1016/s0022-3476(81)80006-6 · Cited by 14
Blouquit, Y., Senan, C., & Rosa, J. (1983) · Journal of Chromatography B Biomedical Sciences and Applications · doi:10.1016/s0378-4347(00)84342-x · Cited by 13
groups, O. B. O. T. Y. A. S.-D. S., Tabesh, M., Callegari, E. T., Gorelik, A., Garland, S. M., Nankervis, A. J., Subasinghe, A. K., & Wark, J. D. (2018) · European Journal of Clinical Nutrition · doi:10.1038/s41430-018-0086-1 · Cited by 12
“HbA1c was measured by a high-performance liquid chromatography method using phenylboronic acid [19].”
MethodLiyanage, P. L. G. C., Lekamwasam, S., Weerarathna, T. P., et al. (2018) · BMC Nephrology · doi:10.1186/s12882-018-1001-7 · Cited by 12
Lin, Y., Lin, C., Chen, H.-M., Kuo, L.-P., Hsieh, C.-E., Wang, X.-H., Cheng, C.-W., Wu, C.-Y., & Chen, Y.-S. (2020) · Sensors · doi:10.3390/s20247274 · Cited by 12
Inorganic phosphate accelerates hemoglobin A1c synthesis
Kunika, K., Itakura, M., & Yamashita, K. (1989) · Life Sciences · doi:10.1016/0024-3205(89)90048-9 · Cited by 12
Falsely low HbA1c value due to a rare variant of hemoglobin J-Baltimore
Barakat, O., Krishnan, S. T. M., & Dhatariya, K. (2008) · Primary care diabetes · doi:10.1016/j.pcd.2008.05.003 · Cited by 12
Rogers, D. G., White, N. H., Santiago, J. V., et al. (1986) · Diabetes Care · doi:10.2337/diacare.9.5.453 · Cited by 12
GLYCOSYLATED HEMOGLOBIN (HbAtc) AND PLASMA LIPOPROTEINS IN JUVENILE ONSET DIABETES MELLITUS
Pollak, A. J., Widhalm, K., Havelec, L., et al. (1980) · Acta Paediatrica · doi:10.1111/j.1651-2227.1980.tb07117.x · Cited by 12
Carvalho, J., Borges‐Machado, F., Barros, D. G. M., Sampaio, A., Marques‐Aleixo, I., Bohn, L., Pizarro, A. I. N., Teixeira, L., Magalhães, J., & Ribeiro, Ó. M. (2021) · BMC Geriatrics · doi:10.1186/s12877-021-02104-1 · Cited by 19
Murai, J., Soga, S., Saito, H., & Koga, M. (2012) · Endocrine Journal · doi:10.1507/endocrj.ej12-0281 · Cited by 11
Kordonouri, O., Kahl, A., Jörres, A., et al. (1999) · Journal of Diabetes and its Complications · doi:10.1016/s1056-8727(99)00055-0 · Cited by 11
Hashimoto, K., Tanikawa, K., Nishikawa, J., et al. (2015) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2014.12.021 · Cited by 10
Valdes, R. (1986) · Biochemical Journal · doi:10.1042/bj2390769 · Cited by 10
Can We Use Plasma Fibronectin Levels as a Marker for Early Diabetic Nephropathy.
Özata, M., Kurt, İ., Azal, Ö., et al. (1995) · Endocrine Journal · doi:10.1507/endocrj.42.301 · Cited by 10
Fast hemoglobins and red blood cell metabolites in citrate phosphate dextrose adenine stored blood.
Zeller, W. P., Eyzaguirre, M., Hannigan, J. J., et al. (1985) · PubMed · Cited by 10
Peters, A., Gromeier, S., Kohlmann, T., Look, D., & Kerner, W. (1996) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem.81.2.8636259 · Cited by 11
ApoE isoforms, treatment of diabetes and the risk of coronary heart disease
Ehara, H. (2012) · World Journal of Diabetes · doi:10.4239/wjd.v3.i3.54 · Cited by 9
La HbA1c en el diagnóstico y en el manejo de la diabetes
Campuzano‐Maya, G., & Sierra, G. L. (2010) · Dialnet (Universidad de la Rioja) · Cited by 9
Silica monolithic membrane as separation medium
Hosoya, K., Ogata, T., Watabe, Y., et al. (2004) · Journal of Chromatography A · doi:10.1016/j.chroma.2004.09.042 · Cited by 9
The Clinical Value of HbA1‐Determinations
Wålinder, O., Wibell, L. B., & Boström, H. (1980) · Acta Medica Scandinavica · doi:10.1111/j.0954-6820.1980.tb12858.x · Cited by 9
Pattanaik, S. K., Pattanaik, S., Dash, M., Sahoo, S., Ray, A., Jena, S., & Rath, D. (2025) · Journal of Ethnopharmacology · doi:10.1016/j.jep.2025.120215 · Cited by 8
Lardinois, C. K., Starich, G. H., Mazzaferri, E. L., & DeLett, A. (1988) · Journal of the American College of Nutrition · doi:10.1080/07315724.1988.10720229 · Cited by 8
Busanello, A., Menezes, V. M., Koller, O. G., Andreia, Â. V., & de Almeida, J. C. (2025) · Trials · doi:10.1186/s13063-025-08720-1 · Cited by 9
“HbA1c will be determined by high-performance liquid chromatography using the Turbo variant II sys-tem [29], with a reference interval of 4.0 to 6.0%.”
InfluentialThe narrow therapeutic window of glycated hemoglobin and assay variability
Hosseini, S. S., Bibler, I., & Charles, M. A. (1999) · Metabolism · doi:10.1016/s0026-0495(99)90236-6 · Cited by 7
Role of Chromatography for Monitoring of Breast Cancer Biomarkers
Ali, I., ALOthman, Z. A., Saleem, K., et al. (2011) · Recent Patents on Biomarkerse · doi:10.2174/2210309011101010089 · Cited by 6
Schmid, R., Pollak, A. J., Vycudilik, W., et al. (1984) · Clinica Chimica Acta · doi:10.1016/0009-8981(84)90320-6 · Cited by 6
Sangiorgio, L., Attardo, T. M., Condorelli, L., & Lunetta, M. (2000) · Archives of Gerontology and Geriatrics · doi:10.1016/s0167-4943(00)00064-9 · Cited by 6
gamma-Glutamyl-transpeptidase in diabetics: a case control study
Colloredo-Mels, G., Bettale, G., Bellati, G., et al. (1988) · Clinica Chimica Acta · doi:10.1016/0009-8981(88)90009-5 · Cited by 6
Arfken, C. L., Schmidt, L. E., McGill, J. B., White, N. H., & Santiago, J. V. (1996) · Journal of Diabetes and its Complications · doi:10.1016/1056-8727(94)00048-4 · Cited by 6
Shah, A. R., Challener, J., Elsey, T. S., Maguire, G. A., Calvin, J., & Rayman, G. A. (1994) · Diabetic Medicine · doi:10.1111/j.1464-5491.1994.tb00278.x · Cited by 5
Vascular risk factors in Japanese non-insulin-dependent diabetic patients with microalbuminuria
Kodama, T., Tomiyama, T., Ishizaki, T., et al. (1992) · Journal of Diabetes and its Complications · doi:10.1016/1056-8727(92)90015-d · Cited by 5
Muñoz, P. A., Celermajer, D. S., Gu, Y., Bradley, S., Wong, J., Constantino, M., McLennan, S., Lau, E., Alison, J. A., & Harmer, A. R. (2024) · Canadian Journal of Diabetes · doi:10.1016/j.jcjd.2024.11.003 · Cited by 5
Madhavan, A. A., Juneja, S., Sen, P., Moulick, R. G., & Bhattacharya, J. (2018) · Nanoscale Research Letters · doi:10.1186/s11671-018-2812-y · Cited by 4
Amiodarone therapy and glucose tolerance ? A prospective trial
Lakhdar, A., FARISH, E., Dunn, F. G., et al. (1988) · European Journal of Clinical Pharmacology · doi:10.1007/bf00615233 · Cited by 4
Mels, G. C., Bettale, G., Bellati, G., et al. (1986) · Acta Diabetologica · doi:10.1007/bf02581351 · Cited by 4
A Rapid Microchromatographic Method for Determination of Hemoglobin AI
Wålinder, O. (1980) · Upsala Journal of Medical Sciences · doi:10.3109/03009738009179182 · Cited by 4
Cohen, M. P. (1986) · Springer eBooks · doi:10.1007/978-1-4612-4938-2_3 · Cited by 4
Tani, S., Imatake, K., Suzuki, Y., Yagi, T., & Takahashi, A. (2024) · Tobacco Induced Diseases · doi:10.18332/tid/195378 · Cited by 3
“Glycated hemoglobin A1c levels were measured using high-performance liquid chromatography 23 .”
Accuracy, Patient Acceptance and Clinical Application of Capillary HbA1c Monitoring
Dunning, P., Weberruss, M., & Ward, G. M. (1991) · Diabetic Medicine · doi:10.1111/j.1464-5491.1991.tb01702.x · Cited by 3
HIV Infection Does Not Explain Elevation of Glycated Hemoglobin among Non-Diabetic Patients in Gabon
Perret, J. L., Ngou-Milama, E., Delaporte, É., et al. (2000) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2000.097 · Cited by 3
Glycated haemoglobin (HBA1C): an update on available methods
Ezegbogu, M. O., & Abdulsalam, K. S. (2018) · Bayero Journal of Pure and Applied Sciences · doi:10.4314/bajopas.v11i1.2 · Cited by 3
“Commercial assays to measure HbA1c became available in 1978 (Davis et al., 1978; Beccaria et al., 1978), and the test gained popularity during the 1980s.”
BackgroundGlycated Hemoglobin and Serum Proteins as Tools for Monitoring
Goldstein, B. J., Jabbour, S. A., & Ahmed, I. (2003) · Wiley eBooks · doi:10.1002/0470862092.d0806 · Cited by 3
Rosenblum, I., Barbolt, T. A., Billhymer, B., & Coulston, F. (1981) · Ecotoxicology and Environmental Safety · doi:10.1016/0147-6513(81)90026-9 · Cited by 3
Determination of Hemoglobin A1C in Diabetic Patients
Almér, L. ‐., & Jeppsson, J. (1982) · Acta Medica Scandinavica · doi:10.1111/j.0954-6820.1982.tb07705.x · Cited by 3
Amador, L. R., Pérez, J. C. O. S., Faxas, E. B., Valdés, F. F., Rojas, S. B., & Mora, I. (2015) · Acta Médica de Cuba · Cited by 2
Evaluation of HbA1c from CGM traces in an Indian population
Majumdar, S., Kalamkar, S. D., Dudhgaonkar, S., Shelgikar, K. M., Ghaskadbi, S., & Goel, P. (2023) · Frontiers in Endocrinology · doi:10.3389/fendo.2023.1264072 · Cited by 2
“Therefore, accurate experimental methods (6) have been developed to measure HbA1c levels.”
MethodEnhanced high-performance liquid chromatographic resolution of hemoglobin A1c at low temperatures
Torelli, J. A., Eklund, P., & Levy, E. (1982) · Journal of Chromatography B Biomedical Sciences and Applications · doi:10.1016/s0378-4347(00)81763-6 · Cited by 2
Glycated hemoglobin, serum proteins, and other markers as tools for monitoring
Gerber, S. M., Stickle, D. F., Ahmed, I., & Jabbour, S. A. (2015) · Wiley eBooks · doi:10.1002/9781118387658.ch59 · Cited by 2
Hemoglobin A1 in Community Care
Åhrén, B., Bitzén, P. ‐., & Scherstén, B. (1982) · Acta Medica Scandinavica · doi:10.1111/j.0954-6820.1982.tb07706.x · Cited by 2
Serum fatty acid composition as a marker of eating habits in normal and diabetic subjects
Hasegawa, T., & Oshima, M. (1999) · Diabetes Research and Clinical Practice · doi:10.1016/s0168-8227(99)00076-5 · Cited by 2
Yu, H., Liu, X., Cheng, X., Fan, X., Shen, Y., Liu, K., Wan, Y., Su, J., Yu, Q., Sun, Z., et al. (2025) · Journal of Biomedical Research · doi:10.7555/jbr.39.20250107 · Cited by 1
Development of Mobile‐Phase Buffers and Evaluation of Analytical Performance for HbA1c Assays
Zhang, Y., Zhang, G., Yang, F., & Zou, Z. (2025) · Biomedical Chromatography · doi:10.1002/bmc.70136 · Cited by 1
Patients who showed paradoxical increase in HbA1c levels after intensification of diabetes treatment
Koga, M., Saito, H., & Kasayama, S. (2014) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2014.12.001 · Cited by 1
Diabetes Mellitus Selected Aspects of Pathophysiology and Clinical Practice
Porte, D., Halter, J. B., de Haën, C., Palmer, J. P., Asplin, C. M., Graf, R. J., & Pfeifer, M. A. (1982) · Springer eBooks · doi:10.1007/978-1-4684-4187-1_1 · Cited by 1
Medical Monitoring and Diagnosis
Chace, D. H. (2015) · Elsevier eBooks · doi:10.1016/b978-0-08-043848-1.00042-0 · Cited by 1
Vergleich verschiedener Methoden zur Bestimmung glykosylierter Hämoglobine
Schlebusch, H., Sorger, M., & Burisch, H. (1984) · Journal of Molecular Medicine · doi:10.1007/bf01721779 · Cited by 1
Regnier, F. E. (1983) · Elsevier eBooks · doi:10.1016/b978-0-12-335780-9.50006-1 · Cited by 1
Ein Routineverfahren zur chromatographischen HB AI-Bestimmung mittels Mikros�ulentechnik
Gain, T., Henderkott, U., & Bottermann, P. (1981) · Journal of Molecular Medicine · doi:10.1007/bf01476579 · Cited by 1
Handelsman, D. J., & Turtle, J. R. (1978) · Australian and New Zealand Journal of Medicine · doi:10.1111/j.1445-5994.1978.tb02582.x
Improved column-chromatographic isolation of glycosylated hemoglobin S.
Cirotto, C., Allegrucci, M., Cartechini, M. G., Compagnucci, P., Santeusanio, F., & Bolli, G. B. (1985) · Clinical Chemistry · doi:10.1093/clinchem/31.4.631
“Chromatography on ion-exchange columns is commonly used in estimating the proportion of total hemoglobin (Hb) that is glycosylated ( 1-4 ).”
BackgroundHb Alc-Bestimmung mittels Flüssigkeitschromatographie
Topić, E. (1984) · Journal of Laboratory Medicine · doi:10.1515/labm.1984.8.7-8.268
Evaluation ofThreeMinicolumn Procedures forMeasuring Hemoglobin A1
McDonald, J. M., & Ladenson, H. (1982)
Self-citationヘモグロビンA1c (HbA1c) 生成反応速度定数を用いた1日平均空腹時血糖値の算定
国香, 清., 板倉光夫, & 亀次郎, 山. (1990) · 糖尿病 · doi:10.11213/tonyobyo1958.33.319
ESTIMATION OF OXIDATIVE STRESS IN TYPE 2 DIABETIC PATIENTS
Ghosh, L. M., Biswas, I. B., & Roy, N. (2017) · Journal of Evolution of Medical and Dental Sciences · doi:10.14260/jemds/2017/387
満夫, 稲., 光重, 西., まり子, 大., 駿一郎, 蔵., & 裕夫, 井. (1979) · 糖尿病 · doi:10.11213/tonyobyo1958.22.811
Ayinbuomwan, E., & Onovughakpo-Sakpa, E. O. (2022) · Nigerian Journal of Experimental and Clinical Biosciences · doi:10.4103/njecp.njecp_3_22
Mori, J.-I., Yamashita, K., & Aizawa, T. (2025) · Cureus · doi:10.7759/cureus.78503
“HbA1c levels were determined using high-performance liquid chromatography [15] with an Arkray HA8181 (Tokyo, Japan).”
Sahu, A. K., Panda, B., Tripathy, A. A., et al. (2025) · Biotechnology Letters · doi:10.1007/s10529-025-03610-7
“However, the method failed to establish a linear relationship between the phase value and the HbA1c; therefore, it failed to replace the present HPLC as the gold standard method (Davis et al. 1978) (Maleska et al. 2017).”
糖尿病者の血糖コントロール及び耐糖能異常の指標としてのGlycosylated Hemoglobin (HbA1) の意義
享, 真., 由夫, 後., & 祐五, 阿. (1979) · 糖尿病 · doi:10.11213/tonyobyo1958.22.1075
Interference Assessment for High‐Performance Liquid Chromatography HbA1c Assays
Zhao, L., Yang, W., Cui, S., Luo, J., Cao, Y., Yan, N., & Wang, H. (2026) · Biomedical Chromatography · doi:10.1002/bmc.70382
Metadata
- Authors
- Davis, J. E., Mcdonald, J. M., & Jarett, L.
- Affiliations
- Washington University in St. Louis (US)
- Venue
- Diabetes
- Publisher
- American Diabetes Association
- Published
- 1978-02-01
- Volume
- 27
- Issue
- 2
- Pages
- 102-107
- ISSN
- 0012-1797 (ISSN-L)
- 1939-327X
- OpenAlex
- W2013055957
- Cited by
- 203
- References
- 0
- Citations by year
- 2026: 1 · 2025: 7 · 2024: 4 · 2023: 3 · 2022: 2 · 2021: 4 · 2020: 3 · 2019: 6 · 2018: 5 · 2017: 3 · 2016: 1 · 2015: 5 · 2014: 2 · 2013: 1 · 2012: 3
- FWCI
- 10.47
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Diabetes (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Clinical Biochemistry › Advanced Glycation End Products research
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Chromatography
- Keywords
- HbA1c, HPLC assay, diabetes mellitus, type 1 diabetes, capillary blood samples, sample preparation, small sample volumes, automated assay
- MeSH terms
- Adolescent, Adult, Age Factors, Child, Child, Preschool, Chromatography, High Pressure Liquid, Diabetes Mellitus, Diabetes Mellitus, Type 1, Glycosides, Hemoglobins, Humans, Middle Aged
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›