The Pharmacokinetics of Insulin After Continuous Subcutaneous Infusion or Bolus Subcutaneous Injection in Diabetic Patients
Abstract
Pharmacokinetic models of insulin were examined in order to describe a plasma concentration-time profile after subcutaneous (s.c.) administration of insulin to the patients with insulin-dependent diabetes mellitus (IDDM) or non-insulin-dependent diabetes mellitus (NIDDM). Diabetic subjects were restricted to those with fasting plasma insulin levels around the lowest limit for insulin assay (5 microU/ml). A one-compartment open model with first-order absorption and elimination was appropriate for estimating the plasma concentration-time profile of insulin injected or infused subcutaneously. In the case of continuous s.c. insulin infusion (CSII) for 1 h at the rate of 3 ml/h (2--3 U/ml), the absorption rate constant (Ka), elimination rate constant (Ke), and distribution volume (Vd) were 0.026 +/- 0.001 min-1 (mean +/- SEM; absorption half-life: 27 min), 0.013 +/- 0.005 min-1 (elimination half-life: 53 min), and 1.99 +/- 0.49 L/kg body wt, respectively. These values did not differ significantly from those generated by single bolus s.c. injection of undiluted insulin (40 U/ml). The calculated areas under the plasma insulin concentration-time curves from time zero to infinity ([AUC] 0 infinity) did not differ after each mode of administration, while the [AUC] 0 infinity after CSII was about 32% of that following intravenous bolus injection (P less than 0.01). The following conclusions can be drawn from these results: (1) the plasma concentration-time profile of insulin after CSII…
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The mechanisms that cause variable and unreliable insulin absorption from a CSII catheter into the circulation are poorly understood.
“The mechanisms that cause variable and unreliable insulin absorption from a CSII catheter into the circulation are poorly understood.”
From Detailed Analysis of Insulin Absorption Variability and the Tissue Response to Continuous Subcutaneous Insulin Infusion Catheter Implantation in Swine (2017) · cites this paper as [10]
Cited by
Sorted by citations
Models of subcutaneous insulin kinetics. A critical review
Nucci, G., & Cobelli, C. (2000) · Computer Methods and Programs in Biomedicine · doi:10.1016/s0169-2607(00)00071-7 · Cited by 189 · see citing works
Hauzenberger, J. R., Hipszer, B. R., Loeum, C., McCue, P. A., DeStefano, M., Torjman, M. C., Kaner, M. T., Dinesen, A. R., Chervoneva, I., Pieber, T. R., et al. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2017.0175 · Cited by 39 · see citing works
Resalat, N., Youssef, J. E., Reddy, R., & Jacobs, P. G. (2017) · IFAC-PapersOnLine · doi:10.1016/j.ifacol.2017.08.2270 · Cited by 15 · see citing works
- Authors
- Kobayashi, T., Sawano, S., Itoh, T., Kosaka, K., Hirayama, H., & Kasuya, Y.
- Affiliations
- Toranomon Hospital (JP)
- Department of Endocrinology and Metabolism, Toranomon Hospital, Okinaka Memorial Institute for Medical Research and Asahi Life Institute for Adult Diseases 2-2-2 Toranomon, Minato-Ku, Tokyo 105, Japan
- Tokyo College, The University of Tokyo (JP)
- ORCID
- Kobayashi, Tetsuro
- Venue
- Diabetes
- Publisher
- American Diabetes Association
- Published
- 1983-04-01
- Volume
- 32
- Issue
- 4
- Pages
- 331-336
- ISSN
- 0012-1797 (ISSN-L)
- 1939-327X
- OpenAlex
- W2024915550
- Cited by
- 86
- References
- 0
- Citations by year
- 2026: 1 · 2025: 2 · 2024: 1 · 2023: 1 · 2022: 1 · 2021: 1 · 2019: 1 · 2018: 2 · 2017: 5 · 2016: 5 · 2015: 3 · 2014: 5 · 2013: 3
- FWCI
- 2.99
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Diabetes (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Surgery › Pancreatic function and diabetes
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
- Keywords
- insulin pharmacokinetics, insulin pump therapy, type 1 diabetes, type 2 diabetes, one-compartment model, absorption kinetics, elimination kinetics, volume of distribution, plasma concentration-time curve, area under the curve
- MeSH terms
- Adult, Biological Availability, Diabetes Mellitus, Female, Humans, Injections, Subcutaneous, Insulin, Insulin Antibodies, Kinetics, Male, Middle Aged, Models, Biological
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review