CoChat

The Insulin Sensitivity Index: Correlation in Dogs Between Values Determined from the Intravenous Glucose Tolerance Test and the Euglycemic Glucose Clamp

Finegood, Diane T, Pacini, Giovanni, Bergman, Richard N · 1984 · Diabetes
Cited by 86

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

We previously proposed the insulin sensitivity index, S1as an absolute measure of whole body tissue sensitivity to insulin. S1 is defined, in the physiologic range of insulin action, as the effect of insulin to augment glucose's ability to reduce its own plasma level. This parameter can be determined from the frequently sampled intravenous glucose tolerance test (IVGTT) by using a digital computer to find the coefficients of a minimal mathematical model of glucose kinetics. In the present study we compared, in normal dogs, S, determined from the IVGTT to an analogous parameter “S1(clamp)” calculated from the euglycemic glucose clamp (EGC). Fifteen pairs of experiments (1 IVGTT and 1 EGC) were performed on 12 animals. IVGTTs: After glucose injection (0.3 g/kg), frequent blood samples were taken over the subsequent 3 h. KG ranged from 1.7 to 4.7 %/min, and integrated insulin from 0.4 to 5.9 (μU/ml) min for 0–60 min. S1 varied over a ninefold range from 1.0 to 9.1 × 10−4 (min−1)/μU/ml), with a mean of 4.3 ± 0.7 × 10−4. Fractional glucose disappearance rate independent of insulin (p1) was 4.3 ± 0.5 %/min. EGCs: Low-rate insulin infusion (8 mU/min from 1 to 150 min) elevated plasma insulin (INS) from 15 ± 4 to 43 ± 10 μU/ml. Glucose was infused (GINF) at 119 ± 20 mg/min to maintain euglycemia. Moderate insulin infusion (40 mU/min: 151–300 min) further elevated plasma insulin (to 176 ± 37 μU/ml) and the requisite glucose infusion (to 372 ± 36 mg/min). S1(clamp) was calculated in steady state as the increase in glucose infusion per increment in insulin above basal, normalized to the basal glucose and body weight [GINF/(Gb × BW × δINS)]. S1(clamp) ranged from 3.1 to 40.5 × 10−4 (dl/kg/min)/μU/ml). The values of S1 and S1(clamp) were highly correlated (r = 0.82, P < 0.005). These studies suggest that the insulin sensitivity index, S1determined from the IVGTT is a useful measure of insulin sensitivity, which is capable of differentiating sensitivities among a normal population.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2337/diab.33.4.362

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 86

Metadata

Authors
Finegood, D. T., Pacini, G., & Bergman, R. N.
Venue
Diabetes
Published
1984-04-01
Volume
33
Issue
4
Pages
362-368
ISSN
  • 0012-1797 (ISSN-L)
  • 1939-327X
OpenAlex
W1967445535
Cited by
86
References
1
FWCI
5.67
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Insulin Sensitivity Index: Correlation in Dogs Between Values Determined from the Intravenous Glucose Tolerance Test and the Euglycemic Glucose Clamp. https://app.cochat.ai/papers/10.2337/diab.33.4.362
The paper
Finegood, D. T., Pacini, G., & Bergman, R. N. (1984). The Insulin Sensitivity Index: Correlation in Dogs Between Values Determined from the Intravenous Glucose Tolerance Test and the Euglycemic Glucose Clamp. Diabetes. https://doi.org/10.2337/diab.33.4.362

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.