Cited by 15Diabetes Management and ResearchDiabetes Management and EducationIntravenous Infusion Technology and Safety

The Pump Life: Patient Responses and Clinical and Technological Problems

Pickup, John C, Sherwin, Robert S, Tamborlane, William V, Rizza, Robert A, Service, F John, The Kroc Collaborative Study Group·1985·Diabetes

Abstract

As part of a randomized, prospective trial in subjects with insulin-dependent diabetes assigned to either continuous subcutaneous insulin infusion (CSII) or to their unchanged conventional insulin treatment (CIT) for 8 mo, patients completed questionnaires dealing with general responses and clinical and technological problems. Although there was no significant difference between treatment groups with respect to the number of patients experiencing severe hypoglycemia (i.e., requiring intravenous glucose or intramuscular glucagon injection), there were nine episodes in six patients during CSII compared with one episode during CIT. Diabetic ketoacidosis occurred significantly more often in the CSII group (nine episodes in eight patients) than in the CIT group (no episodes). A number of CSII-related failures occurred, including omission of premeal bolus, needle dislodgement, pump accidentally turned off, and leakage at the infusion site. At 8 mo, 85% of CSII-treated patients wished to continue indefinitely on the pump, and almost all would continue with self-monitoring of blood glucose even if they Stopped CSII.

Integrity signals

Registry

Crossref · 10.2337/diab.34.3.s37

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cited by

Sorted by citations

Authors
Pickup, J. C., Sherwin, R. S., Tamborlane, W. V., Rizza, R. A., Service, F. J., & The Kroc Collaborative Study Group
Affiliations
  • Guy's Hospital (GB)
  • Yale University (US)
  • Mayo Clinic (US)
Venue
Diabetes
Published
1985-08-01
Volume
34
Issue
Supplement_3
Pages
37-41
ISSN
  • 0012-1797 (ISSN-L)
  • 1939-327X
OpenAlex
W2025555261
Cited by
15
References
0
Citations by year
2017: 1 · 2012: 1
FWCI
0.94
Type
journal article
Language
en
Open access
closed
Locations
  • Diabetes (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
  • Physical Sciences › Engineering › Biomedical Engineering › Intravenous Infusion Technology and Safety
Keywords
insulin pump therapy, type 1 diabetes, severe hypoglycemia, diabetic ketoacidosis, patient satisfaction, conventional insulin therapy, self-monitoring of blood glucose
MeSH terms
Canada, Clinical Trials as Topic, England, Humans, Hypoglycemia, Insulin Infusion Systems, Ketone Bodies, Patient Compliance, Surveys and Questionnaires, United States

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review