Development of the Implantable Glucose Sensor: What Are the Prospects and Why Is It Taking So Long?
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The development of an implantable glucose sensor for use in diabetes was first suggested in the 1960s (1–3). The sensor would provide an alternative to the present discrete methods of glucose determination that are based on intermittent blood sampling. Continuous glucose sensing would be particularly important in the detection and management of hypoglycemia. It would also allow early detection of hyperglycemia and provide a basis for insulin administration at more appropriate dosages and timing or for automatic insulin delivery from a pump. An implantable glucose sensor could also be used in parallel with other existing or potential forms of insulin replacement, such as transplantation or hybrid islet devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY
Clark, L. C., & Lyons, C. (1962) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1962.tb13623.x · Cited by 3,945
A Miniaturized Nafion-Based Glucose Sensor: in vitro and in vivo evaluation in dogs
Moussy, F., Harrison, D. J., & Rajotte, R. V. (1994) · The International Journal of Artificial Organs · doi:10.1177/039139889401700206 · Cited by 67 · cited 1×
“The peroxide-based sensor has been fabricated in the form of a needle and implanted in dogs (35,36), rats (8,12), and pigs (24).”
Method
Cited by
A BioMEMS Review: MEMS Technology for Physiologically Integrated Devices
Grayson, A. C. R., Shawgo, R. S., Johnson, A. M., Flynn, N. T., Li, Y., Cima, M. J., & Langer, R. (2004) · Proceedings of the IEEE · doi:10.1109/jproc.2003.820534 · Cited by 562
Closed-loop insulin delivery—the path to physiological glucose control
Steil, G. (2004) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2003.08.011 · Cited by 313
Sensors for glucose monitoring: technical and clinical aspects
Koschinsky, T., & Heinemann, L. (2001) · Diabetes/Metabolism Research and Reviews · doi:10.1002/dmrr.188 · Cited by 288
Lee, I., Probst, D., Klonoff, D., & Sode, K. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2021.113054 · Cited by 288
Glucose Biosensor Based on the Microcantilever
Pei, J., Tian, F., & Thundat, T. (2004) · Analytical Chemistry · doi:10.1021/ac035048k · Cited by 284
Chu, M. X., Miyajima, K., Takahashi, D., Arakawa, T., Sano, K., Sawada, S.-I., Kudo, H., Iwasaki, Y., Akiyoshi, K., Mochizuki, M., et al. (2011) · Talanta · doi:10.1016/j.talanta.2010.10.055 · Cited by 279
Potentiometric Saccharide Detection Based on the p Ka Changes of Poly(aniline boronic acid)
Shoji, E., & Freund, M. S. (2002) · Journal of the American Chemical Society · doi:10.1021/ja0267371 · Cited by 277
Progress in Boronic Acid-Based Fluorescent Glucose Sensors
Fang, H., Kaur, G., & Wang, B. (2004) · Journal of Fluorescence · doi:10.1023/b:jofl.0000039336.51399.3b · Cited by 245
Can Interstitial Glucose Assessment Replace Blood Glucose Measurements?
Rebrin, K., & Steil, G. M. (2000) · Diabetes Technology & Therapeutics · doi:10.1089/15209150050194332 · Cited by 213
“The answer, as stated by Gough, is the need for more focused research with complete presentation of successful and unsuccessful data.”
Marvin, J. S., & Hellinga, H. W. (1998) · Journal of the American Chemical Society · doi:10.1021/ja972993f · Cited by 179
Nanoporous anti-fouling silicon membranes for biosensor applications
Desai, T. A., Hansford, D. J., Leoni, L., Essenpreis, M., & Ferrari, M. (2000) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(00)00088-9 · Cited by 163
Biomaterial–microvasculature interactions
Sieminski, A. L., & Gooch, K. J. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00149-6 · Cited by 155
Variants of the tissue-sensor array window chamber
Makale, M. T., Chen, P. C., & Gough, D. A. (2005) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.01001.2004 · Cited by 16
Self-citation
Metadata
- Authors
- Gough, D. A., & Armour, J. C.
- Venue
- Diabetes
- Publisher
- American Diabetes Association
- Published
- 1995-09-01
- Volume
- 44
- Issue
- 9
- Pages
- 1005-1009
- ISSN
- 0012-1797 (ISSN-L)
- 1939-327X
- OpenAlex
- W1965636718
- Cited by
- 118
- References
- 2
- FWCI
- 10.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.