Soft contact lens biosensor for in situ monitoring of tear glucose as non-invasive blood sugar assessment

Chu, Ming Xing, Miyajima, Kumiko, Takahashi, Daishi, Arakawa, Takahiro, Sano, Kenji, Sawada, Shin-ichi, Kudo, Hiroyuki, Iwasaki, Yasuhiko +3 more·2011·Talanta

Abstract

A contact lens (CL) biosensor for in situ monitoring of tear glucose was fabricated and tested. Biocompatible 2-methacryloyloxyethyl phosphorylcholine (MPC) polymer and polydimethyl siloxane (PDMS) were employed as the biosensor material. The biosensor consists of a flexible Pt working electrode and a Ag/AgCl reference/counter electrode, which were formed by micro-electro-mechanical systems (MEMS) technique. The electrode at the sensing region was modified with glucose oxidase (GOD). The CL biosensor showed a good relationship between the output current and glucose concentration in a range of 0.03-5.0mM, with a correlation coefficient of 0.999. The calibration range covered the reported tear glucose concentrations in normal and diabetic patients. Also, the CL biosensor was applied to a rabbit for the purpose of tear glucose monitoring. The basal tear glucose was estimated to 0.11 mM. Also, the change of tear glucose induced by the change of blood sugar level was assessed by the oral glucose tolerance test. As a result, tear glucose level increased with a delay of 10 min from blood sugar level. The result showed that the CL biosensor is expected to provide further detailed information about the relationship between dynamics of blood glucose and tear glucose.

Integrity signals

Registry

Crossref · 10.1016/j.talanta.2010.10.055

Cites

29 of 29 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • These reversible optical sensors can quantify a wide range of analytes including pH, metal ions, carbohydrates, and alcohol, as well as temperature.

    “These reversible optical sensors can quantify a wide range of analytes including pH,73 metal ions,74 carbohydrates,75 and alcohol,76 as well as temperature.77”

    From Wearables in Medicine (2018) · cites this paper as [74]

  • Tear glucose concentrations have been demonstrated to exhibit good correlation with blood glucose levels, reflecting diffusion from the lachrymal artery when tears are sampled without eye irritation or stimulation, which can compromise the relationship.

    “In particular, tear glucose concentrations have been demonstrated to exhibit good correlation with blood glucose levels, reflecting the diffusion from the lachrymal artery when the tears are sampled without any eye irritation or stimulation, which can compromise the relationship94, 95, 99-101.”

    From Wearable biosensors for healthcare monitoring (2019) · cites this paper as [100]

  • The requirement for bulky and expensive equipment for signal measurements limits the use of smart contact lenses outside research laboratories or clinical settings by restricting users' external activities.

    “(iv) the requirement for bulky and expensive equipment for signal measurements, which limits the use of smart contact lenses outside of research laboratories or clinical settings by restricting users’ external activities (14, 15, 20, 23).”
  • By considering the correlation between tear glucose level and blood glucose level, a glucose sensor fitted on a contact lens can provide noninvasive monitoring of a user's glucose levels from tear fluids, with a lag time between tear glucose and blood glucose in the range of 10 to 20 min.

    “By considering the correlation between the tear glucose level and blood glucose level (15), a glucose sensor fitted on a contact lens can provide the noninvasive monitoring of user’s glucose levels from tear fluids with a consideration of the lag time between tear glucose level and blood glucose level in the range of 10 to 20 min (13–16).”
  • Opaque electronic materials for sensors, IC chips, metal antennas, and interconnects can block users' vision.

    “These issues include (i) the use of opaque electronic materials for sensors, integrated circuit (IC) chips, metal antennas, and interconnects that can block users’ vision (15, 17, 18);”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Chu, M. X., Miyajima, K., Takahashi, D., Arakawa, T., Sano, K., Sawada, S.-I., Kudo, H., Iwasaki, Y., Akiyoshi, K., Mochizuki, M., & Mitsubayashi, K.
Affiliations
  • Tokyo Medical and Dental University (JP)
  • Kansai University (JP)
Corresponding author
Mitsubayashi, Kohji
Venue
Talanta
Publisher
Elsevier BV
Published
2011-01
Volume
83
Issue
3
Pages
960-965
ISSN
0039-9140 (ISSN-L)
OpenAlex
W2007320634
Cited by
279
References
29
Citations by year
2026: 10 · 2025: 12 · 2024: 24 · 2023: 25 · 2022: 27 · 2021: 32 · 2020: 30 · 2019: 24 · 2018: 19 · 2017: 15 · 2016: 17 · 2015: 13 · 2014: 15 · 2013: 4 · 2012: 8
FWCI
4.02
Type
journal article
Language
en
Open access
closed
Locations
  • Talanta (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • Japan Society for the Promotion of Science
  • Ministry of Education, Culture, Sports, Science and Technology
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrochemical sensors and biosensors
  • Physical Sciences › Chemical Engineering › Bioengineering › Analytical Chemistry and Sensors
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
Keywords
tear glucose, non-invasive glucose monitoring, glucose oxidase, platinum electrode, MEMS electrodes, 2-methacryloyloxyethyl phosphorylcholine, polydimethylsiloxane, diabetes mellitus, oral glucose tolerance test, blood glucose dynamics
MeSH terms
Animals, Blood Glucose, Contact Lenses, Hydrophilic, Humans, Rabbits, Tears, Biosensing Techniques

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review