Computer Simulation of Plasma Insulin and Glucose Dynamics After Subcutaneous Insulin Injection
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
We developed a computer program for the simulation of plasma insulin and glucose dynamics after subcutaneous injection of insulin. The program incorporates a pharmacokinetic model to calculate the time courses of plasma insulin for various combinations of popular preparations (regular, NPH, lente, and ultralente). With the use of a pharmacodynamic model describing the dependence of glucose dynamics on plasma insulin and glucose levels, the program can predict the expected time course of plasma glucose in response to a change in carbohydrate intake, insulin dose, timing, or regimen. A set of typical parameters has been obtained by analysis of data from the literature. The results of several computer simulations are presented showing the effect on a 24-h insulin and glucose profile of systematically changing insulin regimen, dose, timing of meals, or timing of preprandial insulin administration. The program can be used to explore on a theoretical basis the impact of various factors associated with glycemic control in insulin-dependent diabetes mellitus. As an educational tool, the program provides a realistic environment for demonstration of the combined or isolated effects of insulin and diet on glycemia
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quantitative estimation of insulin sensitivity.
Bergman, R. N., Ider, Y. Z., Bowden, C. R., & Cobelli, C. (1979) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1979.236.6.e667 · Cited by 1,874 · cited 1×
“In developing the model, we followed the principles usually associated with the minimal-model approach: to find a concise mathematical formulation to represent the major physiological systems with the fewest parameters (4).”
Method
Cited by
Non-invasive delivery strategies for biologics
Anselmo, A. C., Gokarn, Y., & Mitragotri, S. (2019) · Nature Reviews Drug Discovery · doi:10.1038/nrd.2018.183 · Cited by 665
Continuous glucose monitoring and closed‐loop systems
Hovorka, R. (2006) · Diabetic Medicine · doi:10.1111/j.1464-5491.2005.01672.x · Cited by 443
A physiological model of glucose-insulin interaction in type 1 diabetes mellitus
Lehmann, E. D., & Deutsch, T. (1992) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(92)90058-s · Cited by 401
Makroglou, A., Li, J., & Kuang, Y. (2006) · Applied Numerical Mathematics · doi:10.1016/j.apnum.2005.04.023 · Cited by 367
“(1978) [38] and by Berger and Rodbard (1989) [9].”
BackgroundModels of subcutaneous insulin kinetics. A critical review
Nucci, G., & Cobelli, C. (2000) · Computer Methods and Programs in Biomedicine · doi:10.1016/s0169-2607(00)00071-7 · Cited by 189
“All the models handle soluble (regular) insulin while monomer insulin is only analyzed in [20,23] and intermediate acting insulin (NPH or lente) is only considered in [21].”
BackgroundInfluential
Metadata
- Authors
- Berger, M., & Rodbard, D.
- Venue
- Diabetes Care
- Publisher
- American Diabetes Association
- Published
- 1989-11-01
- Volume
- 12
- Issue
- 10
- Pages
- 725-736
- ISSN
- 0149-5992 (ISSN-L)
- 1935-5548
- OpenAlex
- W2143070237
- Cited by
- 223
- References
- 1
- FWCI
- 4.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.