CoChat

Insulin Antibody Responses After Long-Term Intraperitoneal Insulin Administration via Impiantatile Programmable Insulin Delivery Systems

Olsen, Craig L, Chan, Eve, Turner, Dee S, Iravani, Mohamed, Nagy, Maria, Selam, Jean-Louis, Wong, Nathan D, Waxman, Ken, Charles, M Arthur · 1994 · Diabetes Care
Cited by 43

The DOI matches its Crossref record.

Abstract

OBJECTIVE: To determine whether insulin antibodies are generated in diabetic patients after short- and long-term intraperitoneal insulin use and, if so, whether they are of potential clinical interest. Insulin antibodies commonly develop in diabetic patients who use subcutaneous human insulin, although their clinical significance remains controversial. Few data are available regarding insulin antibody responses to intraperitoneal insulin. RESEARCH DESIGN AND METHODS: We studied insulin antibody levels and clinical diabetes control in 25 type 1 diabetic patients treated for 3-6 years with intraperitoneal surfactant-stabilized porcine modified human insulin delivered by implantable programmable insulin delivery systems. RESULTS: All patients had preimplantation insulin antibody levels <20 μU/ml, with a mean value of 2 ± 2 μU/ml (1 SD). Mean antibody levels increased throughout the study period to a mean maximum of 197 ± 326 μU/ml (P < 0.02) with 11 of 25 (44%) patients' levels exceeding 20 μU/ml (insulin responders). The mean time to significant antibody development was 21.8 ± 4.4 months. Of the 11 responder patients, 4 had clinical syndromes that consisted of increasing daily insulin requirements and/or nocturnal hypoglycemia despite minimal nighttime basal insulin infusion rates associated with peak antibody levels >200 μU/ml. None of the nonresponder patients (antibody levels <20 (μU/ml) had these clinical findings. CONCLUSIONS: Our results indicate that insulin antibody levels observed during intraperitoneal administration of human insulin are 1) similar to those reported during subcutaneous administration; although the rise in antibody level may be delayed compared with subcutaneous human insulin, 2) associated with a patient subset who are insulin antibody responders after switching from subcutaneous to intraperitoneal human insulin, 3) associated with a decrease in levels among responder patients regardless of whether they discontinue or continue pump use, and 4) associated with increased insulin needs and/or nocturnal hypoglycemia despite minimal basal rate insulin infusion at nighttime when antibody levels exceed 200 μU/ml.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2337/diacare.17.3.169

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Olsen, C. L., Chan, E., Turner, D. S., Iravani, M., Nagy, M., Selam, J.-L., Wong, N. D., Waxman, K., & Charles, M. A.
Venue
Diabetes Care
Published
1994-03-01
Volume
17
Issue
3
Pages
169-176
ISSN
  • 0149-5992 (ISSN-L)
  • 1935-5548
OpenAlex
W1992175783
Cited by
43
References
0
FWCI
0.56
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.