CoChat

Lispro Mix25 insulin as premeal therapy in type 2 diabetic patients.

Koivisto, V A, Tuominen, J A, Ebeling, P · 1999 · Diabetes Care
Cited by 58

The DOI matches its Crossref record.

Abstract

OBJECTIVE: Insulin Mix25 is a new premixed insulin analog containing 25% insulin lispro and 75% neutral protamine lispro (NPL) suspension (NPL insulin). The aim of the study was to compare serum glucose and insulin responses after breakfast in type 2 diabetic patients who received Mix25, premixed regular/NPH (30%/70%), or NPH insulin before the meal. RESEARCH DESIGN AND METHODS: We studied 22 type 2 diabetic patients of age 62 +/- 1 years, BMI 30 +/- 1 kg/m2, duration of diabetes 15 +/- 2 years, duration of insulin therapy 6 +/- 1 years, insulin dose 65 +/- 6 U/day, and HbA1c 7.9 +/- 0.2%. Ten healthy individuals (age 56 +/- 1 years, BMI 28 +/- 1 kg/m2) served as control subjects. Each patient (except healthy subjects, who were studied once each) was studied three times in a double-blind, randomized fashion. After an overnight fast, the patients received 36 +/- 4 U of test insulin. Ten minutes after insulin injection, the patients ingested a breakfast meal (512 kcal, 60% carbohydrate, 20% fat, and 20% protein), identical in all studies. Blood samples were taken before and at 10- to 30-min intervals for 240 min after the breakfast meal. RESULTS: The peak rise in serum glucose was lower after Mix25 (76 +/- 7 mg/dl) than after 30/70 (94 +/- 5 mg/dl, P < 0.05) or NPH (113 +/- 4 mg/dl, P < 0.005) insulin. The incremental area under the serum glucose curve was 36% smaller after Mix25 than after 30/70 (P < 0.01) and 56% smaller than after NPH (P < 0.005) insulin. The peak rise in serum insulin concentration was higher after Mix25 (103 +/- 18 mU/l) than after 30/70 (87 +/- 13 mU/l, P < 0.05) or NPH (62 +/- 12 mU/l, P < 0.01) insulin. The incremental area under the serum insulin curve was higher after Mix25 than after 30/70 during the first 2-3 h (P < 0.02), but the difference disappeared by the end of the 4-h follow-up period. After Mix25 injection, there was an inverse correlation between the glucose response to a meal and insulin dose (r = -0.56, P < 0.01) or the incremental area under the serum insulin curve (r = -0.39, P < 0.05). No such correlations were observed with the other insulins. CONCLUSIONS: Because of its faster initial absorption rate, the new premixed insulin analog Mix25 reduces blood glucose response to a breakfast meal in type 2 diabetic patients compared with premixed 30/70 (regular/NPH) or NPH insulin.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2337/diacare.22.3.459

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Koivisto, V. A., Tuominen, J. A., & Ebeling, P.
Affiliations
Department of Medicine, Helsinki University Hospital, Finland.
Venue
Diabetes Care
Published
1999-03-01
Volume
22
Issue
3
Pages
459-462
ISSN
  • 0149-5992
  • 1935-5548
Cited by
58
References
0
Language
en

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.