The Glucose Area Under the Profiles Obtained With Continuous Glucose Monitoring System Relationships With HbAlc in Pediatric Type 1 Diabetic Patients
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
OBJECTIVE—The purpose of this study was to determine whether the continuous glucose monitoring system (CGMS) (MiniMed, Sylmar, CA) 1) is sufficiently representative of the overall metabolic control as assessed by HbA1c, 2) could be used to identify a particular blood glucose threshold value affecting hemoglobin glycation; and 3) is able to show any relationship between particular glycemic profiles and HbA1c levels. RESEARCH DESIGN AND METHODS—Of 44 pediatric patients with type 1 diabetes who wore CGMS devices, 28 subjects were selected for the study. Criteria for inclusion were high levels of HbA1c (≥8%) for more than 1 year or a history of frequent hypoglycemic episodes and a complete CGMS registration for 72 h. Age of the subjects ranged from 5.7 to 24.8 years, the mean duration of disease was 7.63 ± 4.75 years, and the mean HbA1c value was 8.7 ± 1.3%. CGMS data were downloaded and glucose profiles were analyzed. The area under each glucose profile was calculated by means of a professional digital planimeter. RESULTS—The glucose profiles showed a high frequency of prolonged hyperglycemic periods (80% of subjects) and a low frequency of postmeal glycemic peaks (29% of subjects). Postlunch values were significantly correlated with HbA1c levels, but the correlation disappeared when controlling for glucose area values. Glucose area values significantly correlated with HbA1c levels both when considered as a whole (40–400 mg/dl; r = 0.53, P = 0.002) and when considered fractioned (40–150, 40–200, 40–250, 40–300 mg/dl), apart from the 40–90 mg/dl partial area. HbA1c levels were significantly decreased 3 and 6 months after use of CGMS (P = 0.05 and 0.03, respectively, paired Student’s t test) . CONCLUSIONS—HbA1c levels may be decreased by using the information obtained with the CGMS. Three-day glucose profiles are representative of the overall glucose control, because glucose area values correlate with HbA1c levels. The only glucose threshold below which there seems to be no correlation with HbA1c is 90 mg/dl. Only glucose area, and not postprandial glucose values, are directly and independently correlated with HbA1c. Therefore, to improve metabolic control, it is necessary to lower the whole mean 24-h glycemia and not just the postprandial glucose values.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
de Veciana, M., Major, C. A., Morgan, M. A., Asrat, T., Toohey, J. S., Lien, J. M., & Evans, A. T. (1995) · New England Journal of Medicine · doi:10.1056/nejm199511093331901 · Cited by 666
Bode, B. W., Gross, T. M., Thornton, K. R., & Mastrototaro, J. J. (1999) · Diabetes Research and Clinical Practice · doi:10.1016/s0168-8227(99)00113-8 · Cited by 232 · cited 1×
“Study methods The CGMS system is approved for use as a Holter-type monitor; its characteristics have been described repeatedly elsewhere (1,2).”
MethodA Pilot Study of the Continuous Glucose Monitoring System
Kaufman, F. R., Gibson, L. C., Halvorson, M., Carpenter, S., Fisher, L. K., & Pitukcheewanont, P. (2001) · Diabetes Care · doi:10.2337/diacare.24.12.2030 · Cited by 224
Cited by
Klonoff, D. C. (2005) · Diabetes Care · doi:10.2337/diacare.28.5.1231 · Cited by 724
Glycemic Variability: How Do We Measure It and Why Is It Important?
Suh, S., & Kim, J. H. (2015) · Diabetes & Metabolism Journal · doi:10.4093/dmj.2015.39.4.273 · Cited by 439
Assessing Glycemia in Diabetes Using Self-monitoring Blood Glucose and Hemoglobin A 1c
Saudek, C. D., Derr, R. L., & Kalyani, R. R. (2006) · JAMA · doi:10.1001/jama.295.14.1688 · Cited by 373
A Novel Approach to Continuous Glucose Analysis Utilizing Glycemic Variation
McDonnell, C. M., Donath, S. M., Vidmar, S. I., Werther, G. A., & Cameron, F. J. (2005) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2005.7.253 · Cited by 358
Continuous Glucose Monitoring Systems: A Review
Vashist, S. (2013) · Diagnostics · doi:10.3390/diagnostics3040385 · Cited by 261
Metadata
- Authors
- Salardi, S., Zucchini, S., Santoni, R., Ragni, L., Gualandi, S., Cicognani, A., & Cacciari, E.
- Venue
- Diabetes Care
- Publisher
- American Diabetes Association
- Published
- 2002-10-01
- Volume
- 25
- Issue
- 10
- Pages
- 1840-1844
- ISSN
- 0149-5992 (ISSN-L)
- 1935-5548
- OpenAlex
- W2159306965
- Cited by
- 87
- References
- 3
- FWCI
- 3.08
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Glucose Area Under the Profiles Obtained With Continuous Glucose Monitoring System Relationships With HbAlc in Pediatric Type 1 Diabetic Patients. https://app.cochat.ai/papers/10.2337/diacare.25.10.1840
- The paper
- Salardi, S., Zucchini, S., Santoni, R., Ragni, L., Gualandi, S., Cicognani, A., & Cacciari, E. (2002). The Glucose Area Under the Profiles Obtained With Continuous Glucose Monitoring System Relationships With HbAlc in Pediatric Type 1 Diabetic Patients. Diabetes Care. https://doi.org/10.2337/diacare.25.10.1840
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.