Abstract

OBJECTIVE—The rapid-acting insulin analogs aspart and lispro have now been developed in biphasic formulations. This trial compared the postprandial serum glucose control of biphasic insulin aspart 30 (BIAsp 30: 30% aspart, 70% protaminated aspart) with that of biphasic insulin lispro 25 (Mix25: 25% lispro, 75% protaminated lispro) and biphasic human insulin 30 (BHI 30: 30% regular insulin, 70% NPH insulin) in insulin-treated subjects with type 2 diabetes. RESEARCH DESIGN AND METHODS—This was an open-labeled, randomized, single-dose, three-way crossover trial of 61 insulin-treated subjects with type 2 diabetes who had no significant late diabetic complications. BIAsp 30 and Mix25 were injected subcutaneously immediately before a test meal, and BHI 30 was injected 15 min before a test meal. The primary target of analysis was serum glucose excursion 0–5 h after a meal. RESULTS—The postprandial glycemic control with BIAsp 30, as assessed by the 5-h postmeal serum glucose excursion, was superior to that with both BHI 30 and Mix25 (16.6 ± 4.5 vs. 20.1 ± 4.9 and 18.9 ± 6.1 mmol/l per hour, respectively; P < 0.001 and P < 0.05). For BIAsp 30 versus BHI 30, this was supported by a reduced maximum glucose concentration [Cmax(SG)] (−5%; P < 0.05) occurring earlier (−13 min; P < 0.01). Furthermore, BIAsp 30 displayed a higher maximum serum insulin concentration (+101%; P < 0.001) occurring earlier (−55 min; P < 0.001) compared with BHI 30. Compared with Mix25, there was a shorter time to Cmax(SG) (−11 min; P < 0.05) after treatment with BIAsp 30. CONCLUSIONS—This trial demonstrates that BIAsp 30 improves postprandial glycemic control compared with both Mix25 and BHI 30 in subjects with type 2 diabetes.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2337/diacare.25.5.883

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 128

Metadata

Authors
Hermansen, K., Colombo, M., Storgaard, H., Østergaard, A., Kølendorf, K., & Madsbad, S.
Venue
Diabetes Care
Published
2002-05-01
Volume
25
Issue
5
Pages
883-888
ISSN
  • 0149-5992 (ISSN-L)
  • 1935-5548
OpenAlex
W2101930436
Cited by
128
References
6
FWCI
4.71
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.