Cited by 133Diabetes Management and ResearchClinical Laboratory Practices and Quality ControlDiabetes Management and Education

The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.

Rapid Changes in Postprandial Blood Glucose Produce Concentration Differences at Finger, Forearm, and Thigh Sampling Sites

Open access
Ellison, John M., Stegmann, Janet M., Colner, Sandra L., Michael, Ragui H., Sharma, Manoj K., Ervin, Kenneth R., Horwitz, David L.·2002·Diabetes Care

Abstract

OBJECTIVE—To compare pre- and postmeal capillary blood glucose concentrations measured at the finger, forearm, and thigh in adults with diabetes. RESEARCH DESIGN AND METHODS—For phase 1, capillary blood glucose concentrations were measured at six time points (premeal and at ∼60, 90, 120, 150, and 180 min postmeal) using a blood glucose monitoring system and technician-obtained samples collected from finger, forearm, and thigh sites of 42 adults with diabetes. The finger samples were also tested with a laboratory instrument. For phase 2, ∼14 weeks later, the testing procedures were repeated with 38 subjects from the original study population. RESULTS—Meter finger results were accurate at all time points. Alternate sites tended to produce lower glucose readings compared to finger readings at times when glucose was increasing rapidly (60 and 90 min postmeal). Forearm-to-finger differences correlated with rates of glucose change (r = 0.56, P < 0.001), as did the thigh-to-finger differences (r = 0.52, P < 0.001). Other factors, such as subject age, BMI, diabetes type, and insulin dependence did not have a significant impact on site differences. When the testing procedures were repeated with the same subjects, the pattern of site differences was consistent, although individual results were variable. CONCLUSIONS—Changes in blood glucose immediately after a meal may be identified at finger sites before detection at forearm or thigh sites. Alternate site testing appears to be a useful option for routine self-monitoring before meals; however, patients and clinicians should recognize that results may be different from fingertip results when glucose levels are changing rapidly.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2337/diacare.25.6.961

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

Sorted by citations

See all 133

Metadata

Authors
Ellison, J. M., Stegmann, J. M., Colner, S. L., Michael, R. H., Sharma, M. K., Ervin, K. R., & Horwitz, D. L.
Affiliations
LifeScan, Milpitas, California
Venue
Diabetes Care
Published
2002-06-01
Volume
25
Issue
6
Pages
961-964
ISSN
  • 0149-5992 (ISSN-L)
  • 1935-5548
OpenAlex
W2154078343
Cited by
133
References
12
Citations by year
2026: 2 · 2025: 4 · 2024: 1 · 2023: 4 · 2022: 2 · 2021: 2 · 2020: 6 · 2018: 4 · 2017: 3 · 2016: 3 · 2015: 5 · 2014: 1 · 2013: 9 · 2012: 4
FWCI
8.08
Type
journal article
Language
en
Open access
Locations
  • Diabetes Care (publishedVersion)
  • PubMed (publishedVersion)
Funders
American Diabetes Association
Topics
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
  • Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
Keywords
postprandial blood glucose, capillary blood glucose, forearm, thigh, self-monitoring of blood glucose, meter accuracy, diabetes mellitus
MeSH terms
Adult, Blood Glucose, Blood Specimen Collection, Capillaries, Diabetes Mellitus, Type 1, Diabetes Mellitus, Type 2, Female, Fingers, Forearm, Humans, Leg, Male, Middle Aged, Regression Analysis, Time Factors, Blood Glucose Self-Monitoring, Reproducibility of Results, Postprandial Period

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review