Control of Postprandial Plasma Glucose by an Oral Insulin Product (HIM2) in Patients With Type 2 Diabetes
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
OBJECTIVE—The objectives of this exploratory study were to assess the postprandial glucose-lowering effects and evaluate the safety and tolerability of single, escalating doses of an oral insulin product, hexyl-insulin monoconjugate 2 (HIM2), in patients with type 2 diabetes. Subcutaneous insulin and oral placebo were also administered for comparison. RESEARCH DESIGN AND METHODS—Eighteen patients with type 2 diabetes were enrolled in this randomized, single-blind, placebo-controlled, three-way crossover, dose-escalation study. A single dose of each of the following study drugs was administered to each patient on 3 separate days: oral HIM2 (at one of three dose levels: 0.375, 0.5, or 1.0 mg/kg), subcutaneous regular insulin (8 units Humulin R), and oral placebo. At 30 min after dosing, patients ingested a standardized test meal (16 oz/720 calories of Boost Plus). Serial blood samples were collected for determination of plasma glucose and insulin concentrations during the 4-h postdose period. RESULTS—The mean glucose area under the curve for 0 to 240 min (AUC0–240) values were lower following administration of 0.5 and 1.0 mg/kg HIM2 vs. placebo (1,097.1 vs. 1,196.9 and 801.1 vs. 992.1 mg · h−1 · dl−1, respectively). This difference was statistically significant at the 1.0-mg/kg HIM2 dose level. Insulin exposure, as measured by insulin AUC0–240 values, for the 0.375-, 0.5-, and 1.0-mg/kg dose levels of HIM2 were 169.9, 193.1, and 230.8 μU · h−1 · ml−1, respectively; insulin AUC0–240 values for placebo were 165.8, 196.1, and 169.2 μU · h−1 · ml−1, respectively. The mean glucose AUC0–240 values were similar following administration of 0.5 and 1.0 mg/kg HIM2 vs. subcutaneous insulin (1,097.1 vs. 1,048.0 and 801.1 vs. 875.2 mg · h−1 · dl−1, respectively). For pooled data from the 0.5- and 1.0-mg/kg dose groups, the HIM2/subcutaneous insulin ratios for the 2-h postprandial glucose concentration (0.97, 95% CI 0.90–1.06), maximum postprandial glucose concentration (0.99, 95% CI 0.93–1.06), and glucose AUC0–240 (0.98, 95% CI 0.9–1.06) were within 10% of unity, implying glucodynamic equivalence. Although HIM2 (0.5 and 1.0 mg/kg) and subcutaneous insulin (8 units) provided comparable control of postprandial plasma glucose concentrations, HIM2 resulted in peripheral insulin concentrations that were lower than subcutaneous insulin (mean insulin AUC0–240 of 193.1 vs. 233.6 and 230.8 vs. 270.3 μU · h−1 · ml−1, respectively). CONCLUSIONS—Single, oral doses of HIM2 were safe and well tolerated. HIM2 (0.5 and 1.0 mg/kg) was more effective than placebo and as effective as subcutaneous regular insulin (8 units) at controlling postprandial glycemia with respect to the following parameters: 2-h postprandial glucose concentration, maximum glucose concentration, and glucose AUC0–240. This occurred even though peripheral insulin concentrations were lower following the administration of HIM2 (0.5 and 1.0 mg/kg) than subcutaneous insulin. Thus, HIM2 therapy may control postprandial glycemia without causing peripheral hyperinsulinemia in patients with type 2 diabetes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ohkubo, Y., Kishikawa, H., Araki, E., Miyata, T., Isami, S., Motoyoshi, S., Kojima, Y., Furuyoshi, N., & Shichiri, M. (1995) · Diabetes Research and Clinical Practice · doi:10.1016/0168-8227(95)01064-k · Cited by 3,079
Henry, R. R., Gumbiner, B., Ditzler, T., Wallace, P., Lyon, R., & Glauber, H. S. (1993) · Diabetes Care · doi:10.2337/diacare.16.1.21 · Cited by 227
Cited by
Approaches for enhancing oral bioavailability of peptides and proteins
Renukuntla, J., Vadlapudi, A. D., Patel, A., Boddu, S. H. S., & Mitra, A. K. (2013) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2013.02.030 · Cited by 681
Challenges for the oral delivery of macromolecules
Goldberg, M., & Gomez-Orellana, I. (2003) · Nature Reviews Drug Discovery · doi:10.1038/nrd1067 · Cited by 544
Is the oral route possible for peptide and protein drug delivery?
Morishita, M., & Peppas, N. A. (2006) · Drug Discovery Today · doi:10.1016/j.drudis.2006.08.005 · Cited by 515
Emerging Trends in Oral Delivery of Peptide and Protein Drugs
Mahato, R. I., Narang, A. S., Thoma, L., & Miller, D. D. (2003) · Critical Reviews in Therapeutic Drug Carrier Systems · doi:10.1615/critrevtherdrugcarriersyst.v20.i23.30 · Cited by 352
Oral delivery of insulin associated to polymeric nanoparticles in diabetic rats
Damgé, C., Maincent, P., & Ubrich, N. (2007) · Journal of Controlled Release · doi:10.1016/j.jconrel.2006.10.023 · Cited by 351
Metadata
- Authors
- Kipnes, M., Dandona, P., Tripathy, D., Still, J. G., & Kosutic, G.
- Venue
- Diabetes Care
- Publisher
- American Diabetes Association
- Published
- 2003-02-01
- Volume
- 26
- Issue
- 2
- Pages
- 421-426
- ISSN
- 0149-5992 (ISSN-L)
- 1935-5548
- OpenAlex
- W2150729882
- Cited by
- 96
- References
- 2
- FWCI
- 6.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.