Continuous Glucose Monitoring and the Reality of Metabolic Control in Preschool Children With Type 1 Diabetes
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
OBJECTIVE—To determine using the MiniMed continuous glucose monitoring system (CGMS) 1) whether twice-daily insulin injection therapy achieves adequate control in preschool children with type 1 diabetes and 2) whether the CGMS is more informative than self-monitoring of blood glucose (SMBG) regarding glucose control and well tolerated by preschool children and their families. RESEARCH DESIGN AND METHODS—Ten children <6 years of age with type 1 diabetes were monitored twice using the CGMS. The distribution of glucose values was analyzed, particularly the frequency, duration, and distribution of hypoglycemia. We analyzed the accuracy of the CGMS in detecting hypoglycemia as well as the clinical relevance of the difference between CGMS and SMBG values. RESULTS—Although hypoglycemia was more frequent during the night (0.8 nighttime episodes · subject–1 · 24 h–1 vs. 0.3 daytime episodes · subject–1 · 24 h–1), the difference did not reach statistical significance (P = 0.07). However, nighttime episodes lasted longer than daytime episodes (1.2 vs. 0.2 h · subject–1 · 24 h–1, P = 0.006). Hypoglycemia accounted for 7% and normoglycemia for 24%, while hyperglycemia occurred 64% of the time, with postprandial hyperglycemia being an almost universal feature (94 ± 7% of all postmeal values). The CGMS correlated well with SMBG without significant clinical discrepancy. The CGMS sensitivity to detect hypoglycemia was 70% with a specificity of 99%; however, the CGMS detected twice as many total episodes as SMBG (82 vs. 40). CONCLUSIONS—Twice-daily insulin injection rarely achieves control in preschool children with type 1 diabetes. The CGMS is well tolerated by patients and has the advantage of revealing daily glucose trends missed by SMBG.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Evaluating clinical accuracy of systems for self-monitoring of blood glucose
Clarke, W. L., Cox, D., Gonder-Frederick, L. A., Carter, W., & Pohl, S. L. (1987) · Diabetes Care · doi:10.2337/diacare.10.5.622 · Cited by 1,435
A Pilot Study of the Continuous Glucose Monitoring System
Kaufman, F. R., Gibson, L. C., Halvorson, M., Carpenter, S., Fisher, L. K., & Pitukcheewanont, P. (2001) · Diabetes Care · doi:10.2337/diacare.24.12.2030 · Cited by 224
Cited by
Klonoff, D. C. (2005) · Diabetes Care · doi:10.2337/diacare.28.5.1231 · Cited by 724
Continuous glucose monitoring systems for type 1 diabetes mellitus
Langendam, M., Luijf, Y. M., Hooft, L., DeVries, J. H., Mudde, A. H., & Scholten, R. J. (2012) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd008101.pub2 · Cited by 262
Continuous glucose monitoring: an Endocrine Society Clinical Practice Guideline
Klonoff, D. C., Buckingham, B., Christiansen, J. S., Montori, V. M., Tamborlane, W. V., Vigersky, R. A., & Wolpert, H. (2011) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2010-2756 · Cited by 211
7. Diabetes Technology: Standards of Medical Care in Diabetes—2021
American Diabetes Association (2021) · Diabetes Care · doi:10.2337/dc21-s007 · Cited by 202
“Though data from small observational studies demonstrate that rtCGM can be worn by patients,8 years old and the use of rtCGM provides insight to glycemic patterns (61,62), an RCT in children aged 4–9 years did not demonstrate improvements in glycemic control following 6 months of rtCGM use (60).”
BackgroundISPAD Clinical Practice Consensus Guidelines 2018: diabetes technologies
Sherr, J. L., Tauschmann, M., Battelino, T., de Bock, M., Forlenza, G., Roman, R., Hood, K. K., & Maahs, D. M. (2018) · Pediatric Diabetes · doi:10.1111/pedi.12731 · Cited by 197
Metadata
- Authors
- Jeha, G. S., Karaviti, L. P., Anderson, B., O’Brian Smith, E., Donaldson, S., McGirk, T. S., & Haymond, M. W.
- Venue
- Diabetes Care
- Publisher
- American Diabetes Association
- Published
- 2004-12-01
- Volume
- 27
- Issue
- 12
- Pages
- 2881-2886
- ISSN
- 0149-5992 (ISSN-L)
- 1935-5548
- OpenAlex
- W2160057921
- Cited by
- 59
- References
- 3
- FWCI
- 3.63
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Continuous Glucose Monitoring and the Reality of Metabolic Control in Preschool Children With Type 1 Diabetes. https://app.cochat.ai/papers/10.2337/diacare.27.12.2881
- The paper
- Jeha, G. S., Karaviti, L. P., Anderson, B., O’Brian Smith, E., Donaldson, S., McGirk, T. S., & Haymond, M. W. (2004). Continuous Glucose Monitoring and the Reality of Metabolic Control in Preschool Children With Type 1 Diabetes. Diabetes Care. https://doi.org/10.2337/diacare.27.12.2881
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.