CoChat

The Need for Separate Performance Goals for Glucose Sensors in the Hypoglycemic, Normoglycemic, and Hyperglycemic Ranges

Open access
Klonoff, David C. · 2004 · Diabetes Care
Cited by 56

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Blood glucose monitors are an important tool for people with diabetes to assess their physiological status and allow them to properly dose themselves with medication or food. The need to adjust the amount of treatment is greatest when the blood glucose level is in the hypoglycemic range because of the risk of acute brain damage if the condition is not quickly treated. A variety of technologies are available to assist patients with detecting hypoglycemia. How accurate are the various types of technologies at detecting hypoglycemia? Are the new continuous glucose monitoring technologies as accurate as current performance guidelines for home blood glucose monitors specify? In this issue of Diabetes Care , the Diabetes Research in Children Network (DirecNet) collaborative study group concludes (1) that the GlucoWatch G2 Biographer (GW2B) and continuous glucose monitoring systems (CGMSs) do not reliably detect hypoglycemia in children and adolescents. They noted that as few as 31% of GW2B values and as few as 42% of CGMSs (including both first- and second-generation sensors) were within 15 mg/dl of reference serum values. When a hypoglycemia alarm value was set at 60 mg/dl, the GW2B demonstrated that the sensitivity to detect hypoglycemia was 23%, the specificity to detect hypoglycemia was 49%, and the false-alarm incidence was 51%. The two continuous glucose monitors probably performed less accurately in this DirecNet study than many clinicians would expect of new technology that has been approved by the U.S. Food and Drug Administration within the past few years. The performance statistics for glucose monitoring systems that are frequently quoted from the literature or from the package inserts of manufacturers mostly derive from studies that measure patients whose blood glucose levels can be low, normal, or high. Because most patients spend little time in a state of hypoglycemia, the majority of data points …

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2337/diacare.27.3.834

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 56

Metadata

Authors
Klonoff, D. C.
Venue
Diabetes Care
Published
2004-03-01
Volume
27
Issue
3
Pages
834-836
ISSN
  • 0149-5992 (ISSN-L)
  • 1935-5548
OpenAlex
W2093721906
Cited by
56
References
3
FWCI
2.10
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Need for Separate Performance Goals for Glucose Sensors in the Hypoglycemic, Normoglycemic, and Hyperglycemic Ranges. https://app.cochat.ai/papers/10.2337/diacare.27.3.834
The paper
Klonoff, D. C. (2004). The Need for Separate Performance Goals for Glucose Sensors in the Hypoglycemic, Normoglycemic, and Hyperglycemic Ranges. Diabetes Care. https://doi.org/10.2337/diacare.27.3.834

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.