A Two-Center Randomized Controlled Feasibility Trial of Insulin Pump Therapy in Young Children With Diabetes
Open accessThe DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
OBJECTIVE—Our goals were to determine if continuous subcutaneous insulin infusion (CSII), compared with those continuing multiple daily injections (MDIs), can be safely used in young children, if those on CSII will have superior glycemic control, if subjects using CSII will have less hypoglycemia for their level of control, and if families using CSII will report an improved quality of life. RESEARCH DESIGN AND METHODS—We conducted a randomized 1-year feasibility trial comparing CSII with continuing MDIs in preschool children with a history of type 1 diabetes for at least 6 months’ duration. Prospective outcomes included measures of overall glycemic control (HbA1c and continuous glucose monitoring system), the incidence of severe hypoglycemia and diabetic ketoacidosis, the percent of glucose values below 3.9 mmol/l, and the parents’ report of quality of life. RESULTS—The 19 subjects’ ages ranged from 1.7 to 6.1 (mean 3.6) years, duration of diabetes ranged from 0.6 to 2.6 (mean 1.4) years, and baseline HbA1c ranged from 6.7 to 9.6% (mean 7.9%). Seven subjects were male. Nine subjects were randomized to start CSII and 10 to continue on MDI. All baseline characteristics were well balanced. Overall metabolic control, diabetes quality of life, and the incidence of hypoglycemia were similar in the two groups. No subject had diabetic ketoacidosis, while one subject in each group had an episode of severe hypoglycemia. No CSII subject discontinued using the pump during or after the study. CONCLUSIONS—CSII can be a safe and effective method to deliver insulin in young children.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1993) · New England Journal of Medicine · doi:10.1056/nejm199309303291401 · Cited by 24,667
CDC GROWTH CHARTS FOR THE UNITED STATES: METHODS AND DEVELOPMENT 2000
Kuczmarski, R. J., Ogden, C. L., Guo, S. S., Strawn, L. G., Flegal, K. M., & Mei, Z. (2002) · Cited by 6,426
Continuous subcutaneous insulin infusion: an approach to achieving normoglycaemia.
Pickup, J. C., Keen, H., Parsons, J. A., & Alberti, K. G. (1978) · BMJ · doi:10.1136/bmj.1.6107.204 · Cited by 563 · cited 1×
“S ince its introduction in the late 1970s, continuous subcutaneous insulin infusion (CSII), or insulin pump therapy, has become an increasingly popular option for type 1 diabetes management (1,2), particularly following the push for improved metabolic control in the post–Diabetes Control and Complications Trial era (3…”
BackgroundWeissberg-Benchell, J., Antisdel-Lomaglio, J., & Seshadri, R. (2003) · Diabetes Care · doi:10.2337/diacare.26.4.1079 · Cited by 551 · cited 1×
“(20) reported on a broader metaanalysis of 52 studies on CSII, of which 41 were paired design (comparing control before pump and then changes over time on CSII) versus 11 parallel design studies (comparing subjects randomized to CSII versus MDI over time, as with our study), and also found similar trends toward improv…”
BackgroundThe DCCT Research Group (1988) · Diabetes Care · doi:10.2337/diacare.11.9.725 · Cited by 509
Pickup, J., Mattock, M., & Kerry, S. (2002) · BMJ · doi:10.1136/bmj.324.7339.705 · Cited by 483 · cited 1×
“(19) analyzed 12 randomized controlled trials that compared CSII with optimized MDI regimens.”
BackgroundBoland, E. A., Grey, M., Oesterle, A., Fredrickson, L., & Tamborlane, W. V. (1999) · Diabetes Care · doi:10.2337/diacare.22.11.1779 · Cited by 432
Tamborlane, W. V., Sherwin, R. S., Genel, M., & Felig, P. (1979) · New England Journal of Medicine · doi:10.1056/nejm197903153001101 · Cited by 411 · cited 1×
“S ince its introduction in the late 1970s, continuous subcutaneous insulin infusion (CSII), or insulin pump therapy, has become an increasingly popular option for type 1 diabetes management (1,2), particularly following the push for improved metabolic control in the post–Diabetes Control and Complications Trial era (3…”
BackgroundContinuous Subcutaneous Insulin Infusion at 25 Years
Pickup, J., & Keen, H. (2002) · Diabetes Care · doi:10.2337/diacare.25.3.593 · Cited by 397 · cited 1×
“The potential advantages of such therapy over multiple daily injections (MDIs) include ease of insulin administration, improved metabolic control with reduced swings in glucose and decreased risk of hypoglycemia, better matching of insulin to carbohydrate intake, improved coverage of the dawn phenomenon and adjustment…”
BackgroundDoyle (Boland), E. A., Weinzimer, S. A., Steffen, A. T., Ahern, J. A. H., Vincent, M., & Tamborlane, W. V. (2004) · Diabetes Care · doi:10.2337/diacare.27.7.1554 · Cited by 373 · cited 1×
“(21) recently demonstrated improved HbA1c with 16 weeks of CSII as compared with glargine among 32 subjects aged 8–21 years.”
Cited by
Cryer, P. E., Davis, S. N., & Shamoon, H. (2003) · Diabetes Care · doi:10.2337/diacare.26.6.1902 · Cited by 1,160
Misso, M. L., Egberts, K. J., Page, M., O'Connor, D., & Shaw, J. (2010) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd005103.pub2 · Cited by 406
Jeitler, K., Horvath, K., Berghold, A., Gratzer, T. W., Neeser, K., Pieber, T. R., & Siebenhofer, A. (2008) · Diabetologia · doi:10.1007/s00125-008-0974-3 · Cited by 375
“Children with type 1 diabetes mellitus Of the randomised controlled trials found, one [41] used a crossover design, whereas the other two, far more recent investigations [40, 43], were of parallel design.”
BackgroundMethodResultInfluentialCummins, E., Royle, P., Snaith, A., Greene, A., Robertson, L., McIntyre, L., & Waugh, N. (2010) · Health Technology Assessment · doi:10.3310/hta14110 · Cited by 335
Use of Insulin Pump Therapy in the Pediatric Age-Group
Phillip, M., Battelino, T., Rodriguez, H., Danne, T., Kaufman, F., & participants, F. T. C. F. (2007) · Diabetes Care · doi:10.2337/dc07-9922 · Cited by 316
Sensor-Augmented Insulin Pump Therapy: Results of the First Randomized Treat-to-Target Study
Hirsch, I. B., Abelseth, J., Bode, B. W., Fischer, J. S., Kaufman, F. R., Mastrototaro, J., Parkin, C. G., Wolpert, H. A., & Buckingham, B. A. (2008) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2008.0068 · Cited by 297
Self-citationDanne, T., Phillip, M., Buckingham, B. A., Jarosz-Chobot, P., Saboo, B., Urakami, T., Battelino, T., Hanas, R., & Codner, E. (2018) · Pediatric Diabetes · doi:10.1111/pedi.12718 · Cited by 225
“Randomized studies in the preschool group have failed to show better glycemic control.(150,151) However, parents of preschool children who switch from multiple daily injections to insulin pumps report more flexibility and freedom, as well as less stress and anxiety related to their child's care.”
BackgroundSelf-citationPańkowska, E., Błazik, M., Dziechciarz, P., Szypowska, A., & Szajewska, H. (2009) · Pediatric Diabetes · doi:10.1111/j.1399-5448.2008.00440.x · Cited by 209
“In one study (17), data were available only in graphs, and with no response to our request for crude data, they could not be pooled in themeta-analysis.”
BackgroundMethodInfluentialISPAD Clinical Practice Consensus Guidelines 2018: diabetes technologies
Sherr, J. L., Tauschmann, M., Battelino, T., de Bock, M., Forlenza, G., Roman, R., Hood, K. K., & Maahs, D. M. (2018) · Pediatric Diabetes · doi:10.1111/pedi.12731 · Cited by 197
Johnson, S. R., Cooper, M. N., Jones, T. W., & Davis, E. A. (2013) · Diabetologia · doi:10.1007/s00125-013-3007-9 · Cited by 178
“associated with pump therapy [3–5], although some report no improvement or an initial improvement followed by a return to pre-pump levels after a short time [6–9].”
BackgroundISPAD Clinical Practice Consensus Guidelines 2022: Diabetes technologies: Insulin delivery
Sherr, J. L., Schoelwer, M., Dos Santos, T. J., Reddy, L., Biester, T., Galderisi, A., van Dyk, J. C., Hilliard, M. E., Berget, C., & DiMeglio, L. A. (2022) · Pediatric Diabetes · doi:10.1111/pedi.13421 · Cited by 152
Hanas, R., Lindgren, F., & Lindblad, B. (2009) · Pediatric Diabetes · doi:10.1111/j.1399-5448.2008.00441.x · Cited by 129
Benkhadra, K., Alahdab, F., Tamhane, S. U., McCoy, R. G., Prokop, L. J., & Murad, M. H. (2017) · Endocrine · doi:10.1007/s12020-016-1039-x · Cited by 113
Dermatological Complications of Continuous Subcutaneous Insulin Infusion in Children and Adolescents
Conwell, L. S., Pope, E., Artiles, A. M., Mohanta, A., Daneman, A., & Daneman, D. (2008) · The Journal of Pediatrics · doi:10.1016/j.jpeds.2007.10.006 · Cited by 111
Durability of Insulin Pump Use in Pediatric Patients With Type 1 Diabetes
Wood, J. R., Moreland, E. C., Volkening, L. K., Svoren, B. M., Butler, D. A., & Laffel, L. M. B. (2006) · Diabetes Care · doi:10.2337/dc06-1141 · Cited by 98
Hypoglycemia and ketoacidosis with insulin pump therapy in children and adolescents
Hanas, R., & Ludvigsson, J. (2006) · Pediatric Diabetes · doi:10.1111/j.1399-543x.2006.00169.x · Cited by 93
Opipari-Arrigan, L., Fredericks, E. M., Burkhart, N., Dale, L., Hodge, M., & Foster, C. (2007) · Pediatric Diabetes · doi:10.1111/j.1399-5448.2007.00283.x · Cited by 64
Glycemic Parameters with Multiple Daily Injections Using Insulin Glargine Versus Insulin Pump
Garg, S. K., Walker, A. J., Hoff, H. K., D'Souza, A. O., Gottlieb, P. A., & Chase, H. P. (2004) · Diabetes Technology & Therapeutics · doi:10.1089/152091504322783350 · Cited by 60
Brorsson, A. L., Viklund, G., Örtqvist, E., & Lindholm Olinder, A. (2015) · Pediatric Diabetes · doi:10.1111/pedi.12209 · Cited by 52
Davis, S. N., Horton, E. S., Battelino, T., Rubin, R. R., Schulman, K. A., & Tamborlane, W. V. (2010) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2009.0145 · Cited by 40
Metadata
- Authors
- Wilson, D. M., Buckingham, B. A., Kunselman, E. L., Sullivan, M. M., Paguntalan, H. U., & Gitelman, S. E.
- Venue
- Diabetes Care
- Publisher
- American Diabetes Association
- Published
- 2005-01-01
- Volume
- 28
- Issue
- 1
- Pages
- 15-19
- ISSN
- 0149-5992 (ISSN-L)
- 1935-5548
- OpenAlex
- W2105000706
- Cited by
- 195
- References
- 24
- FWCI
- 15.32
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.