Limitation of Fasting Plasma Glucose for the Diagnosis of Diabetes Mellitus
The DOI matches its Crossref record.
Abstract
We have analyzed data from 3370 OGTTs performed during epidemiologic studies in three different ethnic groups (Micronesian, Polynesian, and Melanesian) in various Pacific countries to examine the value of a single fasting plasma glucose ≥ 140 mg/dl as a diagnostic test for diabetes (defined as 2-h plasma glucose ≥ 200 mg/dl). A fasting plasma glucose ≥ 140 mg/dl is a highly specific test for diabetes, specificity in the various populations ranging from 98.1% to 99.7%. On the other hand, the sensitivity of fasting plasma glucose was not high and varied greatly between the populations (46.2%–79.0%). The predictive value of fasting plasma glucose for the diagnosis of diabetes was lowest in populations with a low diabetes prevalence and improved in higher prevalence groups. These data indicate that a fasting plasma glucose ≥ 140 mg/dl is not a good screening test, apart from populations with a high prevalence of diabetes mellitus, and the 2-h postload plasma glucose is preferable.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Diabetes: a 21st century challenge
Zimmet, P. Z., Magliano, D. J., Herman, W. H., & Shaw, J. E. (2014) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(13)70112-8 · Cited by 1,062
Self-citationFrom pre-diabetes to diabetes: diagnosis, treatments and translational research
Khan, R., Chua, Z., Tan, J., Yang, Y., Liao, Z., & Zhao, Y. (2019) · Medicina · doi:10.3390/medicina55090546 · Cited by 484
“FPG≥ 140 mg/dL is a highly specific but rather insensitive test for the diagnosis of DM [33].”
BackgroundTelemedicine application in patients with chronic disease: a systematic review and meta-analysis
Ma, Y., Zhao, C., Zhao, Y., Lu, J., Jiang, H., Cao, Y., & Xu, Y. (2022) · BMC Medical Informatics and Decision Making · doi:10.1186/s12911-022-01845-2 · Cited by 158
“showed that the sensitivity of FBG levels for the diagnosis of diabetes is low, and there are substantial differences between populations[51, 52].”
BackgroundSacks, D. B. (2012) · Tietz Textbook of Clinical Chemistry and Molecular Diagnostics · doi:10.1016/b978-1-4160-6164-9.00046-9 · Cited by 7
Metadata
- Authors
- Taylor, R., & Zimmet, P.
- Venue
- Diabetes Care
- Publisher
- American Diabetes Association
- Published
- 1981-09-01
- Volume
- 4
- Issue
- 5
- Pages
- 556-558
- ISSN
- 0149-5992 (ISSN-L)
- 1935-5548
- OpenAlex
- W2028494108
- Cited by
- 47
- References
- 0
- FWCI
- 2.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.