CoChat

Evaluating the Implementation of the EndoTool Glycemic Control Software System

Open access

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

Purpose.: The purpose of this study was to compare achievement of glycemic control on insulin drips before and after the implementation of EndoTool, a glucose management software system used in a community hospital setting. Methods.: A retrospective chart review was performed of patients on an insulin drip who were managed before and after implementation of the EndoTool software. Fifty patients were selected for each group. Statistical analyses were run to compare metrics gathered between groups. Results.: Patients in the standard care group were on an insulin drip for an average of 23.9 hours compared to 20.9 hours in the EndoTool group (P = 0.38). Hypoglycemia occurred at an average rate of 0.036 events per patient in the standard group and 0.007 events per patient in the EndoTool group (P = 0.17). The average rate of hyperglycemia was 0.358 events per patient in the standard group and 0.283 events per patient in the EndoTool group (P = 0.25). The average time to achieve the blood glucose target was 2.78 and 3.67 hours in the standard and EndoTool groups, respectively (P = 0.27). Total patient values were within target range 45.2% of the time in the standard care group and 47.3% of the time in the EndoTool group (P = 0.71). Conclusion.: Analysis of the implementation of EndoTool in the community hospital setting found no statistically significant differences between groups, although rates of hypo- and hyperglycemia showed a trend toward improved safety in the EndoTool group. These results could be attributed to the conservative parameters the hospital set in the initial phase of EndoTool implementation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2337/ds16-0061

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 15

Metadata

Authors
John, S. M., Waters, K. L., & Jivani, K.
Affiliations
  • Philadelphia College of Osteopathic Medicine (US)
  • Gwinnett Medical Center (US)
Corresponding author
John, Samuel M.
Venue
Diabetes Spectrum
Published
2018-02-01
Volume
31
Issue
1
Pages
26-30
ISSN
  • 1040-9165 (ISSN-L)
  • 1944-7353
OpenAlex
W2767852176
Cited by
15
References
8
Citations by year
2026: 4 · 2025: 1 · 2024: 1 · 2023: 1 · 2022: 3 · 2021: 1 · 2020: 4
FWCI
0.87
Type
journal article
Language
en
Open access
Locations
  • Diabetes Spectrum (publishedVersion, cc-by-nc-nd)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by-nc-nd)
  • PubMed Central (publishedVersion, cc-by-nc-nd)
  • PubMed (publishedVersion)
  • Digital Commons - PCOM (Philadelphia College of Osteopathic Medicine) (submittedVersion, cc-by-nc-nd)
Topics
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Hyperglycemia and glycemic control in critically ill and hospitalized patients
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
  • Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Patient Safety and Medication Errors
Keywords
glycemic control, hypoglycemia, hyperglycemia, community hospitals, diabetes management, software implementation

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.