Electrical measurement of the water content of the stratum corneum in vivo and in vitro under various conditions: comparison between skin surface hygrometer and corneometer in evaluation of the skin surface hydration state.
Open accessThe DOI matches its Crossref record.
Abstract
Two commercially available electrical instruments which evaluate the hydration state of the skin surface were compared in in vitro and in vivo experiments. The skin surface hygrometer (Skicon/200) employs high/frequency conductance, whereas the corneometer (CM 420, CM 820) uses electrical capacitance to determine the level of hydration. In a simulation model of in vivo stratum corneum (SC), the high frequency conductance device showed a much closer correlation with the hydration state of the surface SC (r = 0.99) than the capacitance device (r = 0.79), suggesting that the former can accurately assess the hydration dynamics of SC, particularly that due to the accumulation of easily releasable secondary bound water and free water. Both devices were insensitive to changes of hydration taking place in deeper viable skin tissues, e.g. the accumulated tissue fluids in suction blisters. Although the capacitance device correlated poorly with the hydration dynamics in normal SC, its sensitivity to changes occurring in extremely dry skin, such as scaly psoriatic lesions, suggests its measurements characteristics at an extremely low state of hydration, consisting of mostly bound water, such as noted in pathologic SC.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
EEMCO guidance for the assessment of stratum corneum hydration: electrical methods
Berardesca, E., & European Group for Efficacy Measurements on Cosmetics and Other Topical Products (EEMCO) (1997) · Skin Research and Technology · doi:10.1111/j.1600-0846.1997.tb00174.x · Cited by 493
Impaired sphingomyelinase activity and epidermal differentiation in atopic dermatitis
Jensen, J.-M., Fölster-Holst, R., Baranowsky, A., Schunck, M., Winoto-Morbach, S., Neumann, C., Schütze, S., & Proksch, E. (2004) · Journal of Investigative Dermatology · doi:10.1111/j.0022-202x.2004.22621.x · Cited by 309
Hara, M., Ma, T., & Verkman, A. S. (2002) · Journal of Biological Chemistry · doi:10.1074/jbc.m209003200 · Cited by 271
Tagami, H. (2008) · International Journal of Cosmetic Science · doi:10.1111/j.1468-2494.2008.00459.x · Cited by 195
Self-citationLoss of water from the stratum corneum induces epidermal DNA synthesis in hairless mice
Sato, J., Denda, M., Ashida, Y., & Koyama, J. (1998) · Archives of Dermatological Research · doi:10.1007/s004030050364 · Cited by 31
Metadata
- Authors
- Hashimoto-Kumasaka, K., Takahashi, K., & Tagami, H.
- Venue
- Acta Dermato-Venereologica
- Publisher
- Medical Journals Sweden AB
- Published
- 1993-10-01
- Volume
- 73
- Issue
- 5
- Pages
- 335-339
- ISSN
- 0001-5555 (ISSN-L)
- 1651-2057
- OpenAlex
- W2396689288
- Cited by
- 95
- References
- 0
- FWCI
- 2.57
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.