Electromechanical-assisted gait training after stroke: A systematic review comparing end-effector and exoskeleton devices
Open accessThe DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
OBJECTIVES: Although electromechanical-assisted gait training after stroke seems to be effective, in the absence of a direct comparison between electromechanical devices it is not clear which device may be the most effective for recovery of walking. The aim of this study was therefore to compare the effects of different devices used in gait training after stroke. DATA SOURCES: We searched the Cochrane Stroke Group Trials Register, CENTRAL, MEDLINE, EMBASE, CINAHL, AMED, SPORTDiscus, PEDro, COMPENDEX and INSPEC. In addition, we hand-searched relevant conference proceedings, trials and research registers, checked reference lists and contacted authors to identify further trials. STUDY SELECTION: Randomized studies were included. Authors independently selected trials for inclusion, assessed trial quality and extracted the data. DATA EXTRACTION: Data were extracted with the help of a standardized data extraction form. DATA SYNTHESIS: Data were pooled for meta-analysis. The primary outcome was the proportion of patients walking independently. RESULTS: We included 18 trials involving 885 patients. We found significantly higher rates of independent walking in end-effector compared with exoskeleton-based training (p = 0.03). Complication rates in both groups were comparable. CONCLUSION: The results suggest that the type of electromechanical-assisted device might influence the outcome of gait rehabilitation after stroke.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Preferred Reporting Items for Systematic Reviews and Meta-Analyses: the PRISMA statement
Moher, D., Liberati, A., Tetzlaff, J., Altman, D. G., & for the PRISMA Group (2009) · BMJ · doi:10.1136/bmj.b2535 · Cited by 83,823
Preferred reporting items for systematic reviews and meta-analyses: The PRISMA statement
Moher, D., Liberati, A., Tetzlaff, J., Altman, D. G., & the PRISMA Group* (2009) · Annals of Internal Medicine · doi:10.7326/0003-4819-151-4-200908180-00135 · Cited by 37,554
The Barthel ADL Index: A standard measure of physical disability?
Wade, D. T., & Collin, C. (1988) · International Disability Studies · doi:10.3109/09638288809164105 · Cited by 1,582
Clinical Gait Assessment in the Neurologically Impaired
Holden, M. K., Gill, K. M., Magliozzi, M. R., Nathan, J., & Piehl-Baker, L. (1984) · Physical Therapy · doi:10.1093/ptj/64.1.35 · Cited by 1,499
Treadmill training of paraplegic patients using a robotic orthosis.
Colombo, G., Joerg, M., Schreier, R., & Dietz, V. (2000) · PubMed · Cited by 1,290
The Rivermead Mobility Index: A further development of the Rivermead Motor Assessment
Collen, F. M., Wade, D. T., Robb, G. F., & Bradshaw, C. M. (1991) · International Disability Studies · doi:10.3109/03790799109166684 · Cited by 780
Multicenter Randomized Clinical Trial Evaluating the Effectiveness of the Lokomat in Subacute Stroke
Hidler, J., Nichols, D., Pelliccio, M., Brady, K., Campbell, D. D., Kahn, J. H., & Hornby, T. G. (2009) · Neurorehabilitation and Neural Repair · doi:10.1177/1545968308326632 · Cited by 652
Interrater reliability of the 7-level functional independence measure (FIM)
Dickson, H., & Köhler, F. (2020) · Journal of Rehabilitation Medicine · doi:10.2340/165019779527253256 · Cited by 576
Hornby, T. G., Campbell, D. D., Kahn, J. H., Demott, T., Moore, J. L., & Roth, H. R. (2008) · Stroke · doi:10.1161/strokeaha.107.504779 · Cited by 541
Husemann, B., Müller, F., Krewer, C., Heller, S., & Koenig, E. (2007) · Stroke · doi:10.1161/01.str.0000254607.48765.cb · Cited by 418
Cited by
Winstein, C. J., Stein, J., Arena, R., Bates, B., Cherney, L. R., Cramer, S. C., Deruyter, F., Eng, J. J., Fisher, B., Harvey, R. L., et al. (2016) · Stroke · doi:10.1161/str.0000000000000098 · Cited by 3,293
Billinger, S. A., Arena, R., Bernhardt, J., Eng, J. J., Franklin, B. A., Johnson, C. M., MacKay-Lyons, M., Macko, R. F., Mead, G. E., Roth, E. J., et al. (2014) · Stroke · doi:10.1161/str.0000000000000022 · Cited by 1,529
What Is the Evidence for Physical Therapy Poststroke? A Systematic Review and Meta-Analysis
Veerbeek, J. M., van Wegen, E., van Peppen, R., van der Wees, P. J., Hendriks, E., Rietberg, M., & Kwakkel, G. (2014) · PLoS ONE · doi:10.1371/journal.pone.0087987 · Cited by 1,203
“Gait training using an apparatus which guides the walking cycle by electromechanical driven footplates or exoskeleton [8,106,107] was investigated in 16 RCTs (N = 766, PEDro score range 4 [108,109] to 8 [110,111]) [96,102,108–123], including patients in the early rehabilitation phase [96,110,113–115,118–123], late reh…”
Electromechanical-assisted training for walking after stroke
Mehrholz, J., Thomas, S., Werner, C., Kugler, J., Pohl, M., & Elsner, B. (2017) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd006185.pub4 · Cited by 564
Self-citationRobot-assisted Therapy in Stroke Rehabilitation
Chang, W. H., & Kim, Y.-H. (2013) · Journal of Stroke · doi:10.5853/jos.2013.15.3.174 · Cited by 499
Nam, K. Y., Kim, H. J., Kwon, B. S., Park, J.-W., Lee, H. J., & Yoo, A. (2017) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-017-0232-3 · Cited by 302
Morone, G., Paolucci, S., Cherubini, A., De Angelis, D., Venturiero, V., Coiro, P., & Iosa, M. (2017) · Neuropsychiatric Disease and Treatment · doi:10.2147/ndt.s114102 · Cited by 297
Robotic gait rehabilitation and substitution devices in neurological disorders: where are we now?
Calabrò, R. S., Cacciola, A., Bertè, F., Manuli, A., Leo, A., Bramanti, A., Naro, A., Milardi, D., & Bramanti, P. (2016) · Neurological Sciences · doi:10.1007/s10072-016-2474-4 · Cited by 259
Electromechanical-assisted training for walking after stroke
Mehrholz, J., Thomas, S., Kugler, J., Pohl, M., & Elsner, B. (2020) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd006185.pub5 · Cited by 254
Self-citationWearable lower limb robotics: A review
Viteckova, S., Kutilek, P., & Jirina, M. (2013) · Biocybernetics and Biomedical Engineering · doi:10.1016/j.bbe.2013.03.005 · Cited by 221
Powered exoskeletons for bipedal locomotion after spinal cord injury
Contreras-Vidal, J. L., A Bhagat, N., Brantley, J., Cruz-Garza, J. G., He, Y., Manley, Q., Nakagome, S., Nathan, K., Tan, S. H., Zhu, F., et al. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/3/031001 · Cited by 216
Hand Rehabilitation Robotics on Poststroke Motor Recovery
Yue, Z., Zhang, X., & Wang, J. (2017) · Behavioural Neurology · doi:10.1155/2017/3908135 · Cited by 195
“as the limited range of motion and the dead point issues [56].”
BackgroundThe Present and Future of Robotic Technology in Rehabilitation
Laut, J., Porfiri, M., & Raghavan, P. (2016) · Current Physical Medicine and Rehabilitation Reports · doi:10.1007/s40141-016-0139-0 · Cited by 179
“Hence, the development of devices for gait rehabilitation has received substantial attention, with positive results [21, 29].”
Hobbs, B., & Artemiadis, P. (2020) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2020.00019 · Cited by 178
“The critical difference of this paper compared to previous reviews (Dickstein, 2008; Vallery et al., 2008; Marchal-Crespo and Reinkensmeyer, 2009; Schwartz et al., 2009; Díaz et al., 2011; Horno et al., 2011; Morone et al., 2011; Conesa et al., 2012; Mehrholz and Pohl, 2012; Pennycott et al., 2012; Chang and Kim, 2013…”
ResultNew Evidence for Therapies in Stroke Rehabilitation
Dobkin, B. H., & Dorsch, A. (2013) · Current Atherosclerosis Reports · doi:10.1007/s11883-013-0331-y · Cited by 146
“To date, the devices have generally not led to greater overall gains in over-ground walking parameters than the same intensity of more conventional physical therapy [39].”
Background
Metadata
- Authors
- Mehrholz, J., & Pohl, M.
- Venue
- Journal of Rehabilitation Medicine
- Published
- 2012
- Volume
- 44
- Issue
- 3
- Pages
- 193-199
- ISSN
- 1650-1977 (ISSN-L)
- OpenAlex
- W1991058300
- Cited by
- 193
- References
- 25
- FWCI
- 11.15
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.