Physiologic Monitoring Alarm Load on Medical/Surgical Floors of a Community Hospital
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
UNLABELLED: It has been known to the public that high frequency of false and/or unnecessary alarms from patient monitoring devices causes "alarm fatigue" in critical care. But little is known about the impact to care on the less acute patients located outside the critical care areas, such as the traditional medical/surgical (med/surg) floor. METHODS: As part of a larger population management study, we initiated continuous physiological monitoring to 79 beds of floor patients in a community hospital. In order to qualify the patient monitoring alarm load for subacute medical and surgical floor patients, we assessed alarm data from April 2009 to January 2010. A standard critical care monitoring system (Philips IntelliVue MP-5 and Telemetry) was installed and set to the default alarm limits. All waveform data available for the patient (typically ECG, RESP, PPG at 125hz 8 bit), all alarm conditions declared by the monitoring system, and 1 minute parameter trend data were saved to disk every 8 hours for all patients. A monitoring care protocol was created to determine whether the patient was monitored via the hardwired bedside or wirelessly via telemetry. Alarms were not announced on the care unit but instead notifications were the responsibility of remote telehealth center personnel. We retrospectively evaluated the frequency of alarms over specific physiologic thresholds (n= 4104 patients) and conducted adjudication of all alarms based on a smaller sampling (n=30 patients). RESULTS: For all patients, the average hours of monitoring per patient were 16.5 hours with a standard deviation (s) of 8.3 hours and a median of 22 hours. The average number of alarms (all severities) per patient was 69.7 (s =90.3, median =28) alarms. When this is adjusted to the duration of monitoring, the average per patient, per day rate was 95.6 (s =124.2, median =34.2) alarms. The adjudicated sample (n=30 patients) resulted in 34% of critical alarms (lethal arrhythmias, extreme high or low heart rate [HR], extreme desaturation, apnea) being true and 63% of the high priority alarms (high or low HR, high or low RR, Low SpO(2), pause, Missed Beat, Pair PVCs, Pacer Not Pace, Non Sustain VT, Irregular HR, Multiform) being true. Analysis of alarm history resulted in the ability to reduce the HR alarm load by more than 50% with a simple limit adjustment of high HR from 120 to 130 bpm and a 36% or 65% reduction in SpO(2) alarm load by reducing the SpO(2) limit from 90% to 85% or 80% respectively. CONCLUSION: 1) Standard critical care alarm limits appear be too sensitive for subacute care areas of the hospital. 2) For most patients these alarm limits do not create a significant alarm load; however, for a small number of patients they cause a significant alarm load. 3) Alarm loads can be controlled with alarm limit settings appropriate to the population. 4) Current technology for HR and SpO(2) appear suitable for continuous monitoring of this population.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lawless (1994) · doi:10.1097/00003246-199406000-00017 · Cited by 406
Taenzer, A. H., Pyke, J. B., McGrath, S. P., & Blike, G. T. (2010) · Anesthesiology · doi:10.1097/aln.0b013e3181ca7a9b · Cited by 315
Alarm limit settings for early warning systems to identify at risk patients
Burgess, L. P. A., Herdman, T. H., Berg, B. W., Feaster, W. W., & Hebsur, S. (2009) · Journal of Advanced Nursing · doi:10.1111/j.1365-2648.2009.05048.x · Cited by 42
Cited by
Monitor Alarm Fatigue : An Integrative Review
Cvach, M. (2012) · Biomedical Instrumentation & Technology · doi:10.2345/0899-8205-46.4.268 · Cited by 632
Sandau, K. E., Funk, M., Auerbach, A., Barsness, G. W., Blum, K., Cvach, M., Lampert, R., May, J. L., McDaniel, G. M., Perez, M. V., et al. (2017) · Circulation · doi:10.1161/cir.0000000000000527 · Cited by 342
Paine, C. W., Goel, V. V., Ely, E., Stave, C. D., Stemler, S., Zander, M., & Bonafide, C. P. (2016) · Journal of Hospital Medicine · doi:10.1002/jhm.2520 · Cited by 183
“Finally, though not necessarily a limitation, several studies were conducted by authors involved in or funded by the medical device industry.(11,15,19,31,32) This has the potential to introduce bias, although we have no indication that the quality of the science was adversely impacted.”
BackgroundRayo, M. F., & Moffatt-Bruce, S. D. (2015) · BMJ Quality & Safety · doi:10.1136/bmjqs-2014-003373 · Cited by 115
Chaparro, J. D., Beus, J. M., Dziorny, A. C., Hagedorn, P. A., Hernandez, S., Kandaswamy, S., Kirkendall, E. S., McCoy, A. B., Muthu, N., & Orenstein, E. W. (2022) · Applied Clinical Informatics · doi:10.1055/s-0042-1748856 · Cited by 76
Metadata
- Authors
- Gross, B., Dahl, D., & Nielsen, L.
- Venue
- Biomedical Instrumentation & Technology
- Published
- 2011-03-16
- Volume
- 45
- Issue
- s1
- Pages
- 29-36
- ISSN
- 0899-8205 (ISSN-L)
- 1943-5967
- OpenAlex
- W2009489907
- Cited by
- 59
- References
- 3
- FWCI
- 3.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.