Patient self-inflicted lung injury: implications for acute hypoxemic respiratory failure and ARDS patients on non-invasive support
The DOI matches its Crossref record; 79 of the 79 references it cites were found in a registry or an index.
Abstract
The role of spontaneous breathing among patients with acute hypoxemic respiratory failure and ARDS is debated: while avoidance of intubation with noninvasive ventilation (NIV) or high-flow nasal cannula improves clinical outcome, treatment failure worsens mortality. Recent data suggest patient self-inflicted lung injury (P-SILI) as a possible mechanism aggravating lung damage in these patients. P-SILI is generated by intense inspiratory effort yielding: (A) swings in transpulmonary pressure (i.e. lung stress) causing the inflation of big volumes in an aerated compartment markedly reduced by the disease-induced aeration loss; (B) abnormal increases in transvascular pressure, favouring negative-pressure pulmonary edema; (C) an intra-tidal shift of gas between different lung zones, generated by different transmission of muscular force (i.e. pendelluft); (D) diaphragm injury. Experimental data suggest that not all subjects are exposed to the development of P-SILI: patients with a PaO2/FiO2 ratio below 200 mmHg may represent the most at risk population. For them, current evidence indicates that high-flow nasal cannula alone may be superior to intermittent sessions of low-PEEP NIV delivered through face mask, while continuous high-PEEP helmet NIV likely promotes treatment success and may mitigate lung injury. The optimal initial noninvasive treatment of hypoxemic respiratory failure/ARDS remains however uncertain; high-flow nasal cannula and high-PEEP helmet NIV are promising tools to enhance success of the approach, but the best balance between these techniques has yet to be identified. During noninvasive support, careful clinical monitoring remains mandatory for prompt detection of treatment failure, in order not to delay intubation and protective ventilation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bellani, G., Laffey, J. G., Pham, T., Fan, E., Brochard, L., Esteban, A., Gattinoni, L., van Haren, F., Larsson, A., McAuley, D. F., et al. (2016) · JAMA · doi:10.1001/jama.2016.0291 · Cited by 5,766
High-Flow Oxygen through Nasal Cannula in Acute Hypoxemic Respiratory Failure
Frat, J.-P., Thille, A. W., Mercat, A., Girault, C., Ragot, S., Perbet, S., Prat, G., Boulain, T., Morawiec, E., Cottereau, A., et al. (2015) · New England Journal of Medicine · doi:10.1056/nejmoa1503326 · Cited by 2,342
Esteban, A. (2002) · JAMA · doi:10.1001/jama.287.3.345 · Cited by 1,779
Official ERS/ATS clinical practice guidelines: noninvasive ventilation for acute respiratory failure
Rochwerg, B., Brochard, L., Elliott, M. W., Hess, D., Hill, N. S., Nava, S., Navalesi, P., Antonelli, M., Brozek, J., Conti, G., et al. (2017) · European Respiratory Journal · doi:10.1183/13993003.02426-2016 · Cited by 1,668
Self-citationBriel, M., Meade, M., Mercat, A., Brower, R. G., Talmor, D., Walter, S. D., Slutsky, A. S., Pullenayegum, E., Zhou, Q., Cook, D., et al. (2010) · JAMA · doi:10.1001/jama.2010.218 · Cited by 1,467
Mechanical Ventilation to Minimize Progression of Lung Injury in Acute Respiratory Failure
Brochard, L., Slutsky, A., & Pesenti, A. (2017) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201605-1081cp · Cited by 1,274
Hilbert, G., Gruson, D., Vargas, F., Valentino, R., Gbikpi-Benissan, G., Dupon, M., Reiffers, J., & Cardinaud, J. P. (2001) · New England Journal of Medicine · doi:10.1056/nejm200102153440703 · Cited by 1,045
Antonelli, M., Conti, G., Rocco, M., Bufi, M., De Blasi, R. A., Vivino, G., Gasparetto, A., & Meduri, G. U. (1998) · New England Journal of Medicine · doi:10.1056/nejm199808133390703 · Cited by 1,014
Self-citationAn Index Combining Respiratory Rate and Oxygenation to Predict Outcome of Nasal High-Flow Therapy
Roca, O., Caralt, B., Messika, J., Samper, M., Sztrymf, B., Hernández, G., García-de-Acilu, M., Frat, J.-P., Masclans, J. R., & Ricard, J.-D. (2019) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201803-0589oc · Cited by 810
&NA; (2001) · Survey of Anesthesiology · doi:10.1097/00132586-200110000-00014 · Cited by 797
Lung Stress and Strain during Mechanical Ventilation for Acute Respiratory Distress Syndrome
Chiumello, D., Carlesso, E., Cadringher, P., Caironi, P., Valenza, F., Polli, F., Tallarini, F., Cozzi, P., Cressoni, M., Colombo, A., et al. (2008) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200710-1589oc · Cited by 777
Antonelli, M., Conti, G., Moro, M., Esquinas, A., Gonzalez-Diaz, G., Confalonieri, M., Pelaia, P., Principi, T., Gregoretti, C., Beltrame, F., et al. (2001) · Intensive Care Medicine · doi:10.1007/s00134-001-1114-4 · Cited by 757
Self-citationAntonelli, M., Conti, G., Bufi, M., Costa, M. G., Lappa, A., Rocco, M., Gasparetto, A., & Meduri, G. U. (2000) · JAMA · doi:10.1001/jama.283.2.235 · Cited by 730
Self-citationBellani, G., Laffey, J. G., Pham, T., Madotto, F., Fan, E., Brochard, L., Esteban, A., Gattinoni, L., Bumbasirevic, V., Piquilloud, L., et al. (2017) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201606-1306oc · Cited by 667
Self-citationFailure of high-flow nasal cannula therapy may delay intubation and increase mortality
Kang, B. J., Koh, Y., Lim, C.-M., Huh, J. W., Baek, S., Han, M., Seo, H.-S., Suh, H. J., Seo, G. J., Kim, E. Y., et al. (2015) · Intensive Care Medicine · doi:10.1007/s00134-015-3693-5 · Cited by 657
Physiologic Effects of High-Flow Nasal Cannula in Acute Hypoxemic Respiratory Failure
Mauri, T., Turrini, C., Eronia, N., Grasselli, G., Volta, C. A., Bellani, G., & Pesenti, A. (2017) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201605-0916oc · Cited by 641
PUTENSEN, C., ZECH, S., WRIGGE, H., ZINSERLING, J., STÜBER, F., VON SPIEGEL, T., & MUTZ, N. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.164.1.2001078 · Cited by 638
CONFALONIERI, M., POTENA, A., CARBONE, G., PORTA, R. D., TOLLEY, E. A., & UMBERTO MEDURI, G. (1999) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.160.5.9903015 · Cited by 629
Noninvasive Ventilation in Severe Hypoxemic Respiratory Failure: A Randomized Clinical Trial
Ferrer, M., Esquinas, A., Leon, M., Gonzalez, G., Alarcon, A., & Torres, A. (2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200301-072oc · Cited by 620
Evolution of Diaphragm Thickness during Mechanical Ventilation. Impact of Inspiratory Effort
Goligher, E. C., Fan, E., Herridge, M. S., Murray, A., Vorona, S., Brace, D., Rittayamai, N., Lanys, A., Tomlinson, G., Singh, J. M., et al. (2015) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201503-0620oc · Cited by 608
Spontaneous Effort Causes Occult Pendelluft during Mechanical Ventilation
Yoshida, T., Torsani, V., Gomes, S., De Santis, R. R., Beraldo, M. A., Costa, E. L. V., Tucci, M. R., Zin, W. A., Kavanagh, B. P., & Amato, M. B. P. (2013) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201303-0539oc · Cited by 575
Maggiore, S. M., Idone, F. A., Vaschetto, R., Festa, R., Cataldo, A., Antonicelli, F., Montini, L., De Gaetano, A., Navalesi, P., & Antonelli, M. (2014) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201402-0364oc · Cited by 546
Self-citationPatel, B. K., Wolfe, K. S., Pohlman, A. S., Hall, J. B., & Kress, J. P. (2016) · JAMA · doi:10.1001/jama.2016.6338 · Cited by 545
Antonelli, M., Conti, G., Esquinas, A., Montini, L., Maggiore, S. M., Bello, G., Rocco, M., Maviglia, R., Pennisi, M. A., Gonzalez-Diaz, G., et al. (2007) · Critical Care Medicine · doi:10.1097/01.ccm.0000251821.44259.f3 · Cited by 533
Self-citationDelclaux, C., L'Her, E., Alberti, C., Mancebo, J., Abroug, F., Conti, G., Guérin, C., Schortgen, F., Lefort, Y., Antonelli, M., et al. (2000) · JAMA · doi:10.1001/jama.284.18.2352 · Cited by 512
Self-citationRoca, O., Messika, J., Caralt, B., García-de-Acilu, M., Sztrymf, B., Ricard, J.-D., & Masclans, J. R. (2016) · Journal of Critical Care · doi:10.1016/j.jcrc.2016.05.022 · Cited by 512
Corley, A., Caruana, L. R., Barnett, A. G., Tronstad, O., & Fraser, J. F. (2011) · British Journal of Anaesthesia · doi:10.1093/bja/aer265 · Cited by 496
Noninvasive Pressure Support Ventilation in Patients With Acute Respiratory Failure
Wysocki, M., Tric, L., Wolff, M. A., Millet, H., & Herman, B. (1995) · Chest · doi:10.1378/chest.107.3.761 · Cited by 491
Carteaux, G., Millán-Guilarte, T., De Prost, N., Razazi, K., Abid, S., Thille, A. W., Schortgen, F., Brochard, L., Brun-Buisson, C., & Mekontso Dessap, A. (2016) · Critical Care Medicine · doi:10.1097/ccm.0000000000001379 · Cited by 491
Nasal high-flow therapy delivers low level positive airway pressure
Parke, R., McGuinness, S., & Eccleston, M. (2009) · British Journal of Anaesthesia · doi:10.1093/bja/aep280 · Cited by 490
Sztrymf, B., Messika, J., Bertrand, F., Hurel, D., Leon, R., Dreyfuss, D., & Ricard, J.-D. (2011) · Intensive Care Medicine · doi:10.1007/s00134-011-2354-6 · Cited by 463
Physiologic Effects of Noninvasive Ventilation during Acute Lung Injury
L'Her, E., Deye, N., Lellouche, F., Taille, S., Demoule, A., Fraticelli, A., Mancebo, J., & Brochard, L. (2005) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200402-226oc · Cited by 395
Lemiale, V., Mokart, D., Resche-Rigon, M., Pène, F., Mayaux, J., Faucher, E., Nyunga, M., Girault, C., Perez, P., Guitton, C., et al. (2015) · JAMA · doi:10.1001/jama.2015.12402 · Cited by 378
Duan, J., Han, X., Bai, L., Zhou, L., & Huang, S. (2017) · Intensive Care Medicine · doi:10.1007/s00134-016-4601-3 · Cited by 360
Lung Opening and Closing during Ventilation of Acute Respiratory Distress Syndrome
Caironi, P., Cressoni, M., Chiumello, D., Ranieri, M., Quintel, M., Russo, S. G., Cornejo, R., Bugedo, G., Carlesso, E., Russo, R., et al. (2010) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200905-0787oc · Cited by 358
Non-invasive ventilation in community-acquired pneumonia and severe acute respiratory failure
Carrillo, A., Gonzalez-Diaz, G., Ferrer, M., Martinez-Quintana, M. E., Lopez-Martinez, A., Llamas, N., Alcazar, M., & Torres, A. (2012) · Intensive Care Medicine · doi:10.1007/s00134-012-2475-6 · Cited by 358
Benefits and risks of success or failure of noninvasive ventilation
Demoule, A., Girou, E., Richard, J.-C., Taille, S., & Brochard, L. (2006) · Intensive Care Medicine · doi:10.1007/s00134-006-0324-1 · Cited by 337
A Randomized, Prospective Evaluation of Noninvasive Ventilation for Acute Respiratory Failure
MARTIN, T. J., HOVIS, J. D., COSTANTINO, J. P., BIERMAN, M. I., DONAHOE, M. P., ROGERS, R. M., KREIT, J. W., SCIURBA, F. C., STILLER, R. A., & SANDERS, M. H. (2000) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.161.3.9808143 · Cited by 333
Azoulay, E., Lemiale, V., Mokart, D., Nseir, S., Argaud, L., Pène, F., Kontar, L., Bruneel, F., Klouche, K., Barbier, F., et al. (2018) · JAMA · doi:10.1001/jama.2018.14282 · Cited by 333
Nasal high flow clears anatomical dead space in upper airway models
Möller, W., Celik, G., Feng, S., Bartenstein, P., Meyer, G., Eickelberg, O., Schmid, O., & Tatkov, S. (2015) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00934.2014 · Cited by 320
Pressures Delivered By Nasal High Flow Oxygen During All Phases of the Respiratory Cycle
Parke, R. L., & McGuinness, S. P. (2013) · Respiratory Care · doi:10.4187/respcare.02358 · Cited by 313
Yoshida, T., Uchiyama, A., Matsuura, N., Mashimo, T., & Fujino, Y. (2012) · Critical Care Medicine · doi:10.1097/ccm.0b013e3182451c40 · Cited by 312
Antonelli, M., Conti, G., Pelosi, P., Gregoretti, C., Pennisi, M. A., Costa, R., Severgnini, P., Chiaranda, M., & Proietti, R. (2002) · Critical Care Medicine · doi:10.1097/00003246-200203000-00019 · Cited by 309
Self-citationThe "baby lung" became an adult
Gattinoni, L., Marini, J. J., Pesenti, A., Quintel, M., Mancebo, J., & Brochard, L. (2016) · Intensive Care Medicine · doi:10.1007/s00134-015-4200-8 · Cited by 304
Use of high-flow nasal cannula oxygenation in ICU adults: a narrative review
Papazian, L., Corley, A., Hess, D., Fraser, J. F., Frat, J.-P., Guitton, C., Jaber, S., Maggiore, S. M., Nava, S., Rello, J., et al. (2016) · Intensive Care Medicine · doi:10.1007/s00134-016-4277-8 · Cited by 304
Mauri, T., Alban, L., Turrini, C., Cambiaghi, B., Carlesso, E., Taccone, P., Bottino, N., Lissoni, A., Spadaro, S., Volta, C. A., et al. (2017) · Intensive Care Medicine · doi:10.1007/s00134-017-4890-1 · Cited by 294
Goligher, E. C., Brochard, L. J., Reid, W. D., Fan, E., Saarela, O., Slutsky, A. S., Kavanagh, B. P., Rubenfeld, G. D., & Ferguson, N. D. (2019) · The Lancet Respiratory Medicine · doi:10.1016/s2213-2600(18)30366-7 · Cited by 275
Yoshida, T., Uchiyama, A., Matsuura, N., Mashimo, T., & Fujino, Y. (2013) · Critical Care Medicine · doi:10.1097/ccm.0b013e3182711972 · Cited by 262
Esophageal Manometry and Regional Transpulmonary Pressure in Lung Injury
Yoshida, T., Amato, M. B. P., Grieco, D. L., Chen, L., Lima, C. A. S., Roldan, R., Morais, C. C. A., Gomes, S., Costa, E. L. V., Cardoso, P. F. G., et al. (2018) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201709-1806oc · Cited by 258
Self-citationFrat, J.-P., Ragot, S., Coudroy, R., Constantin, J.-M., Girault, C., Prat, G., Boulain, T., Demoule, A., Ricard, J.-D., Razazi, K., et al. (2018) · Critical Care Medicine · doi:10.1097/ccm.0000000000002818 · Cited by 253
Respiratory mechanics during exercise in endurance‐trained men and women
Guenette, J. A., Witt, J. D., McKenzie, D. C., Road, J. D., & Sheel, A. W. (2007) · The Journal of Physiology · doi:10.1113/jphysiol.2006.126466 · Cited by 247
Non-invasive ventilation for acute hypoxemic respiratory failure: intubation rate and risk factors
Thille, A. W., Contou, D., Fragnoli, C., Córdoba-Izquierdo, A., Boissier, F., & Brun-Buisson, C. (2013) · Critical Care · doi:10.1186/cc13103 · Cited by 243
High Positive End-Expiratory Pressure Renders Spontaneous Effort Noninjurious
Morais, C. C. A., Koyama, Y., Yoshida, T., Plens, G. M., Gomes, S., Lima, C. A. S., Ramos, O. P. S., Pereira, S. M., Kawaguchi, N., Yamamoto, H., et al. (2018) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201706-1244oc · Cited by 239
Negative-Pressure Pulmonary Edema
Bhattacharya, M., Kallet, R. H., Ware, L. B., & Matthay, M. A. (2016) · Chest · doi:10.1016/j.chest.2016.03.043 · Cited by 224
Antonelli, M., Pennisi, M. A., Pelosi, P., Gregoretti, C., Squadrone, V., Rocco, M., Cecchini, L., Chiumello, D., Severgnini, P., Proietti, R., et al. (2004) · Anesthesiology · doi:10.1097/00000542-200401000-00007 · Cited by 218
Self-citationGristina, G. R., Antonelli, M., Conti, G., Ciarlone, A., Rogante, S., Rossi, C., & Bertolini, G. (2011) · Critical Care Medicine · doi:10.1097/ccm.0b013e3182227a27 · Cited by 206
Self-citationDemoule, A., Chevret, S., Carlucci, A., Kouatchet, A., Jaber, S., Meziani, F., Schmidt, M., Schnell, D., Clergue, C., Aboab, J., et al. (2016) · Intensive Care Medicine · doi:10.1007/s00134-015-4087-4 · Cited by 194
Helmet CPAP vs. oxygen therapy in severe hypoxemic respiratory failure due to pneumonia
Brambilla, A. M., Aliberti, S., Prina, E., Nicoli, F., Forno, M. D., Nava, S., Ferrari, G., Corradi, F., Pelosi, P., Bignamini, A., et al. (2014) · Intensive Care Medicine · doi:10.1007/s00134-014-3325-5 · Cited by 191
Yoshida, T., Roldan, R., Beraldo, M. A., Torsani, V., Gomes, S., De Santis, R. R., Costa, E. L. V., Tucci, M. R., Lima, R. G., Kavanagh, B. P., et al. (2016) · Critical Care Medicine · doi:10.1097/ccm.0000000000001649 · Cited by 185
Cuquemelle, E., Pham, T., Papon, J.-F., Louis, B., Danin, P.-E., & Brochard, L. (2012) · Respiratory Care · doi:10.4187/respcare.01681 · Cited by 182
Taccone, P., Hess, D., Caironi, P., & Bigatello, L. M. (2004) · Critical Care Medicine · doi:10.1097/01.ccm.0000142577.63316.c0 · Cited by 181
Use of Noninvasive Ventilation in Patients with Acute Respiratory Failure, 2000–2009
Walkey, A. J., & Wiener, R. S. (2013) · Annals of the American Thoracic Society · doi:10.1513/annalsats.201206-034oc · Cited by 172
Schwabbauer, N., Berg, B., Blumenstock, G., Haap, M., Hetzel, J., & Riessen, R. (2014) · BMC Anesthesiology · doi:10.1186/1471-2253-14-66 · Cited by 167
Volume-controlled Ventilation Does Not Prevent Injurious Inflation during Spontaneous Effort
Yoshida, T., Nakahashi, S., Nakamura, M. A. M., Koyama, Y., Roldan, R., Torsani, V., De Santis, R. R., Gomes, S., Uchiyama, A., Amato, M. B. P., et al. (2017) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201610-1972oc · Cited by 162
Chanques, G., Riboulet, F., Molinari, N., Carr, J., Jung, B., Prades, A., Galia, F., Futier, E., Constantin, J.-M., & Jaber, S. (2013) · PubMed · Cited by 159
Transpulmonary pressure: importance and limits
Grieco, D. L., Chen, L., & Brochard, L. J. (2017) · Annals of Translational Medicine · doi:10.21037/atm.2017.07.22 · Cited by 154
Self-citationPressure support ventilation attenuates ventilator-induced protein modifications in the diaphragm
Futier, E., Constantin, J., Combaret, L., Mosoni, L., Roszyk, L., Sapin, V., Attaix, D., Jung, B., Jaber, S., & Bazin, J.-É. (2008) · Critical Care · doi:10.1186/cc7010 · Cited by 152
Mauri, T., Galazzi, A., Binda, F., Masciopinto, L., Corcione, N., Carlesso, E., Lazzeri, M., Spinelli, E., Tubiolo, D., Volta, C. A., et al. (2018) · Critical Care · doi:10.1186/s13054-018-2039-4 · Cited by 142
Ventilatory mechanics and expiratory flow limitation during exercise in normal subjects
Olafsson, S., & Hyatt, R. E. (1969) · Journal of Clinical Investigation · doi:10.1172/jci106015 · Cited by 136
Bellani, G., Grasselli, G., Droghi, M. T., Mauri, T., Coppadoro, A., Brochard, L. J., & Pesenti, A. M. (2016) · Critical Care · doi:10.1186/s13054-016-1290-9 · Cited by 135
Variability of inspired oxygen concentration with nasal cannulas.
Bazuaye, E. A., Stone, T. N., Corris, P. A., & Gibson, G. J. (1992) · Thorax · doi:10.1136/thx.47.8.609 · Cited by 130
Mauri, T., Grasselli, G., Suriano, G., Eronia, N., Spadaro, S., Turrini, C., Patroniti, N. A., Bellani, G., & Pesenti, A. M. (2016) · Anesthesiology · doi:10.1097/aln.0000000000001103 · Cited by 115
Effect of a heated humidifier during continuous positive airway pressure delivered by a helmet
Chiumello, D., Chierichetti, M., Tallarini, F., Cozzi, P., Cressoni, M., Polli, F., Colombo, R., Castelli, A., & Gattinoni, L. (2008) · Critical Care · doi:10.1186/cc6875 · Cited by 70
Recurrent high-permeability pulmonary edema associated with diabetic ketoacidosis
Brun‐Buisson, C., Bonnet, F. J., Bergeret, S., Lemaire, F., & RAPIN, M. (1985) · Critical Care Medicine · doi:10.1097/00003246-198501000-00015 · Cited by 57
Coudroy, R., Frat, J., Boissier, F., Contou, D., Robert, R., & Thille, A. W. (2017) · Critical Care Medicine · doi:10.1097/ccm.0000000000002929 · Cited by 54
Sklar, M. C., Dres, M., Rittayamai, N., West, B., Grieco, D. L., Telías, I., Junhasavasdikul, D., Rauseo, M., Pham, T. O., Madotto, F., et al. (2018) · Annals of Intensive Care · doi:10.1186/s13613-018-0432-4 · Cited by 49
Self-citationGarcía-de-Acilu, M., Marín‐Corral, J., Vázquez, A., Ruano, L., Magret, M., Ferrer, R., Masclans, J. R., & Roca, O. (2017) · Critical Care Medicine · doi:10.1097/ccm.0000000000002647 · Cited by 41
Guiding ventilation with transpulmonary pressure
Yoshida, T., Grieco, D. L., & Brochard, L. J. (2018) · Intensive Care Medicine · doi:10.1007/s00134-018-5483-3 · Cited by 26
Self-citationNasal High Flow Delivered within the Helmet: A New Noninvasive Respiratory Support
Mauri, T., Spinelli, E., Mariani, M., Guzzardella, A., Prete, C. D., Carlesso, E., Tortolani, D., Tagliabue, P. F., Pesenti, A. M., & Grasselli, G. (2018) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201806-1124le · Cited by 19
Cited by
Grieco, D. L., Menga, L. S., Cesarano, M., Rosà, T., Spadaro, S., Bitondo, M. M., Montomoli, J., Falò, G., Tonetti, T., Cutuli, S. L., et al. (2021) · JAMA · doi:10.1001/jama.2021.4682 · Cited by 473
Self-citationFerreyro, B. L., Angriman, F., Munshi, L., Del Sorbo, L., Ferguson, N. D., Rochwerg, B., Ryu, M. J., Saskin, R., Wunsch, H., da Costa, B. R., et al. (2020) · JAMA · doi:10.1001/jama.2020.9524 · Cited by 425
ERS clinical practice guidelines: high-flow nasal cannula in acute respiratory failure
Oczkowski, S., Ergan, B., Bos, L., Chatwin, M., Ferrer, M., Gregoretti, C., Heunks, L., Frat, J.-P., Longhini, F., Nava, S., et al. (2022) · European Respiratory Journal · doi:10.1183/13993003.01574-2021 · Cited by 388
Grieco, D. L., Maggiore, S. M., Roca, O., Spinelli, E., Patel, B. K., Thille, A. W., Barbas, C. S. V., de Acilu, M. G., Cutuli, S. L., Bongiovanni, F., et al. (2021) · Intensive Care Medicine · doi:10.1007/s00134-021-06459-2 · Cited by 286
Self-citationGrieco, D. L., Menga, L. S., Raggi, V., Bongiovanni, F., Anzellotti, G. M., Tanzarella, E. S., Bocci, M. G., Mercurio, G., Dell’Anna, A. M., Eleuteri, D., et al. (2020) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201904-0841oc · Cited by 192
Self-citation
Metadata
- Authors
- Grieco, D. L., Menga, L. S., Eleuteri, D., & Antonelli, M.
- Venue
- Minerva Anestesiologica
- Publisher
- Edizioni Minerva Medica
- Published
- 2019-09
- Volume
- 85
- Issue
- 9
- Pages
- 1014-1023
- ISSN
- 0375-9393 (ISSN-L)
- 1827-1596
- OpenAlex
- W2973055803
- Cited by
- 249
- References
- 79
- FWCI
- 23.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.