The DOI matches its Crossref record; 20 of the 21 references it cites were found in a registry or an index.
The Analysis of PPG Morphology: Investigating the Effects of Aging on Arterial Compliance
Open accessAbstract
This study presents the variations of photoplethysmogram (PPG) morphology with age. PPG measurement is done noninvasively at the index finger on both right and left hands for a sample of erectile dysfunction (ED) subjects. Some parameters are derived from the analysis of PPG contour showed in association with age. The age is found to be an important factor that affects the contour of PPG signals which accelerates the disappearance of PPG’s dicrotic notch and PPG’s inflection point as well. Arterial compliance is found to be degraded with age due to the fall of arterial elasticity. This study approaches the establishment of usefulness of PPG’s contour analysis as an investigator to the changes in the elastic properties of the vascular system, and as a detector of early sub-clinical atherosclerosis.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In a study with participants ranging in age from 30 to 60+, Yousef et al. found that there is no significant increase in pulse magnitude measured at the index finger with an increase in age.”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [88]
In the citing paper
“This work suggests that the decrease in vessel compliance will contribute more to variations in a PPG waveform than other effects of aging [88].”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [88]
Citations
Cites
Photoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967
Is Pulse Pressure Useful in Predicting Risk for Coronary Heart Disease?
Franklin, S. S., Khan, S. A., Wong, N. D., Larson, M. G., & Levy, D. A. (1999) · Circulation · doi:10.1161/01.cir.100.4.354 · Cited by 1,756
Determination of age-related increases in large artery stiffness by digital pulse contour analysis
Millasseau, S., Kelly, R. P., Ritter, J., & Chowienczyk, P. (2002) · Clinical Science · doi:10.1042/cs1030371 · Cited by 624
Arterial Stiffness: A New Cardiovascular Risk Factor?
Arnett, D. K., Evans, G. W., & Riley, W. A. (1994) · American Journal of Epidemiology · doi:10.1093/oxfordjournals.aje.a117315 · Cited by 486
Utility of the Photoplethysmogram in Circulatory Monitoring
Reisner, A. T., Shaltis, P., McCombie, D. B., Asada, H. H., Warner, D. S., & Warner, M. A. A. (2008) · Anesthesiology · doi:10.1097/aln.0b013e31816c89e1 · Cited by 365
Klocke, R., Cockcroft, J. R., Taylor, G. J., Hall, I. R., & Blake, D. R. (2003) · Annals of the Rheumatic Diseases · doi:10.1136/ard.62.5.414 · Cited by 190
Validation of a device to measure arterial pulse wave velocity by a photoplethysmographic method
Loukogeorgakis, S., Dawson, R., Phillips, N., Martyn, C. N., & Greenwald, S. E. (2002) · Physiological Measurement · doi:10.1088/0967-3334/23/3/309 · Cited by 164
Detection and Processing Techniques of FECG Signal for Fetal Monitoring
Hasan, M. A., Reaz, M. B. I., Ibrahimy, M. I., Hussain, M. S., & Uddin, J. (2009) · Biological Procedures Online · doi:10.1007/s12575-009-9006-z · Cited by 150
Self-citationAllen, J., Frame, J. R., & Murray, A. (2002) · Physiological Measurement · doi:10.1088/0967-3334/23/2/312 · Cited by 86
Zahedi, E., Chellappan, K., Ali, M. A. M., & Singh, H. (2007) · Cardiovascular Engineering An International Journal · doi:10.1007/s10558-007-9037-5 · Cited by 60
Self-citation
Cited by
Sorted by citations
Items 101–125 of 125
Analysis of Pulse Wave Morphology Measured by Photoplethysmography During Arm Position Changes
Skripal’, A. V., Геннадиевич, В. Д., Dobdin, S. Y., Сагайдачный, А. А., Usanov, A. D., Antonov, A. V., & Оленко, Е. С. (2025) · Journal of Biomedical Photonics & Engineering · doi:10.18287/jbpe25.11.020310 · Cited by 3
Morphology-Aware HRV Estimation from Wrist PPG in Sedentary Scenarios
Hu, C., Pham, H., & Ma, D. (2025) · ACM International Joint Conference on Pervasive and Ubiquitous Computing (UbiComp) · doi:10.1145/3714394.3756171 · Cited by 2
Neural network models for predicting vascular age from PPG signals: A comparative study
Abrisham, K. P., Alipour, K., Tarvirdizadeh, B., & Ghamari, M. (2024) · IET Wireless Sensor Systems · doi:10.1049/wss2.12103 · Cited by 2
Dehghanojamahalleh, S., Gamage, P. T., Ahmed, M., Petersen, C., Matthew, B. P., Hyacinth, K., Weerasinghe, Y., Subasi, E., Subasi, M. M., & Kaya, M. (2025) · BioMedInformatics · doi:10.3390/biomedinformatics5020024 · Cited by 2
Digital Volume Pulse Analysis to Differentiate Diabetic From Non-Diabetic Subjects
Qawqzeh, Y. (2019) · Communications in Mathematics and Applications · doi:10.26713/cma.v10i4.1266 · Cited by 3
PASS: A Novel PPG-based Aortic Stenosis Screening System
Kang, L., Yang, R., Liu, Y., Zhou, A., Ma, H., & Cui, H. Z. (2025) · Proceedings of the ACM on Interactive Mobile Wearable and Ubiquitous Technologies · doi:10.1145/3749548 · Cited by 1
Jiang, F., Chen, W., Chen, X., Feng, Y., Miao, J., Jiao, C., & Chen, H. (2018) · IEEE International Conference on Signal and Image Processing (ICSIP) · doi:10.1109/siprocess.2018.8600438 · Cited by 1
Kamarul, A. B. (2016) · IEEE-EMBS Conference on Biomedical Engineering and Sciences · doi:10.1109/iecbes.2016.7843501
Patrones en senales de Saturacion de Oxıgeno en Sangre
Ávalos, J. M., Corona, C. A. C., & Rodríguez, C. V. (2017) · Informática y Sistemas Revista de Tecnologías de la Informática y las Comunicaciones · doi:10.33936/isrtic.v1i2.840
Comparison of Acceleration Plethysmogram Acquired Using Optical Signal and Pressure Signal
Shriram, R., Martin, B., Sundhararajan, M., & Daimiwal, N. (2017) · International Journal of Signal Processing Image Processing and Pattern Recognition · doi:10.14257/ijsip.2017.10.9.06
Cardiovascular Disease Classification using Photoplethysmography Signals- Survey
Divya, R., & T., P. (2019) · International Journal of Computer Applications · doi:10.5120/ijca2019918532
Recommendation for Measuring Digital Volume Pulse in Mobile Application: For Healthy Normal Subject
Seok, H. S., & Shin, H. (2021) · IEEE Access · doi:10.1109/access.2021.3077639
Indexing Cerebrovascular Health Using Near-infrared SpectroscopyPreprint
Afkhami, R. G., Walker, F. R., Ramadan, S. A., Wong, R. H. X., & Johnson, S. J. (2021) · medRxiv · doi:10.1101/2021.05.09.21256921
Hyperuricemia Prediction Using Photoplethysmogram and Arteriograph
Dubey, A. K., Gupta, U., & Jain, S. G. (2021) · Computers, materials & continua/Computers, materials & continua (Print) · doi:10.32604/cmc.2022.021987
Recommendation in Measuring Digital Volume Pulse for Mobile Application (Preprint)Preprint
Seok, H. S., & Shin, H. (2020) · doi:10.2196/preprints.24159
PPG SİNYALLERİNİN TQWT TABANLI AYRIŞTIRILMASI YOLUYLA KAN BASINCI VE KALP ATIŞ HIZI TAHMİNİ
KÖKLÜKAYA, F. S., & Öztürk, M. (2023) · DergiPark (Istanbul University) · doi:10.17780/ksujes.1356287
Tanç, Y. H., & Öztürk, M. (2024) · Kahramanmaraş Sütçü İmam Üniversitesi Mühendislik Bilimleri Dergisi · doi:10.17780/ksujes.1376860
Wu, D., Ono, R., Wang, S., Kobayashi, Y., & Liu, H. (2024) · Journal of Biomechanical Science and Engineering · doi:10.1299/jbse.24-00325
Lain, J., Chen, S.-Y., Lee, C.-W., & Lin, T. (2025) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2025.2558045
PPG-basis: A python-based toolbox for fast photoplethysmogram decomposition and reconstruction
Putcha, A., Keyal, R., Piasecki, L., Sharma, A., Shmuylovich, L., Lou, Y., Kosorok, M., & Bai, W. (2026) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2026.109424
Hemodynamic Study on Exercise-Based Cardiovascular Rehabilitation and Health Promotion
Zhang, Y., Zhang, X., Wang, C., & Liu, K. (2026) · IntechOpen eBooks · doi:10.5772/intechopen.1016142
Zheng, W., Xu, X., Song, Y., Cao, Y., Sun, Z., Dong, K., & Liu, Q. (2026) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2026.118419
Metadata
- Authors
- Yousef, Q., Reaz, M. B. I., & Ali, M. A. M.
- Affiliations
- Taibah University (SA)
- National University of Malaysia (MY)
- Venue
- Measurement Science Review
- Publisher
- Walter de Gruyter GmbH
- Published
- 2012-01-01
- Volume
- 12
- Issue
- 6
- ISSN
- 1335-8871 (ISSN-L)
- OpenAlex
- W2014822627
- Cited by
- 126
- References
- 21
- Citations by year
- 2026: 4 · 2025: 11 · 2024: 11 · 2023: 20 · 2022: 23 · 2021: 17 · 2020: 8 · 2019: 9 · 2018: 9 · 2017: 5 · 2016: 3 · 2015: 6
- FWCI
- 1.09
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by-nc-nd
- Locations
- Measurement Science Review (publishedVersion, cc-by-nc-nd)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Keywords
- photoplethysmogram, aging, arterial compliance, arterial elasticity, dicrotic notch, inflection point, erectile dysfunction, subclinical atherosclerosis, vascular elasticity
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review