Our primary objective in this study was to design and implement the FAME Lab PHS Calculator software (PHSFL) (www.famelab.gr/research/downloads), a free tool to calculate the predicted heat strain of an individual based on ISO 7933:2018. Our secondary objective was to optimize the practicality of the PHSFL by incorporating knowledge from other ISO standards and published literature. The third objective of this study was to assess: (i) the criterion-related validity of the PHSFL by comparing its results against those obtained using the original ISO 7933:2018 code; and (ii) the construct validity of the PHSFL by comparing its results against those obtained via field experiments performed in human participants during work in the heat. Our analysis for criterion validity demonstrates that PHSFL provides valid results within the required computational accuracy, according to Annex F of ISO 7933:2018. The construct validity showed that root mean square errors (RMSE) and 95% limits of agreement (LOA) were minimal between measured and predicted core temperature (RMSE: 0.3°C; LOA: 0.06 ± 0.58°C) and small between measured and predicted mean skin temperature (RMSE: 1.1°C; LOA: 0.59 ± 1.83°C). In conclusion, the PHSFL software demonstrated strong criterion-related and construct-related validity.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2486/indhealth.2018-0216

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Research works printed but not linked: 16

  1. 1) Piil JF, Lundbye-Jensen J, Christiansen L, Ioannou L, Tsoutsoubi L, Dallas CN, Mantzios K, Flouris AD, Nybo L (2018) High prevalence of hypohydration in occupations with heat stress—perspectives for performance in combined cognitive and motor tasks. PLoS One 13, e0205321. · DOI · Paper page
  2. 6) de Freitas CR, Grigorieva EA (2017) A comparison and appraisal of a comprehensive range of human thermal climate indices. Int J Biometeorol 61, 487–512. · DOI · Paper page
  3. 7) de Freitas CR, Grigorieva EA (2015) A comprehensive catalogue and classification of human thermal climate indices. Int J Biometeorol 59, 109–20. · DOI · Paper page
  4. 8) Bröde P, Fiala D, Lemke B, Kjellstrom T (2018) Estimated work ability in warm outdoor environments depends on the chosen heat stress assessment metric. Int J Biometeorol 62, 331–45. · DOI
  5. 9) Lamarche DT, Meade RD, D’Souza AW, Flouris AD, Hardcastle SG, Sigal RJ, Boulay P, Kenny GP (2017) The recommended Threshold Limit Values for heat exposure fail to maintain body core temperature within safe limits in older working adults. J Occup Environ Hyg 14, 703–11. · DOI · Paper page
  6. 11) Meade RD, Poirier MP, Flouris AD, Hardcastle SG, Kenny GP (2016) Do the threshold limit values for work in hot conditions adequately protect workers? Med Sci Sports Exerc 48, 1187–96. · DOI
  7. 13) Malchaire J, Piette A, Kampmann B, Mehnert P, Gebhardt H, Havenith G, Den Hartog E, Holmer I, Parsons K, Alfano G, Griefahn B (2001) Development and validation of the predicted heat strain model. Ann Occup Hyg 45, 123–35. · DOI
  8. 23) Bröde P, Kampmann B (2019) Accuracy of metabolic rate estimates from heart rate under heat stress—an empirical validation study concerning ISO 8996. Ind Health 57, 615–20. · DOI
  9. 24) Kamon E, Belding HS (1971) Heart rate and rectal temperature relationships during work in hot humid environments. J Appl Physiol 31, 472–7. · doi:10.1152/jappl.1971.31.3.472
  10. 25) Malchaire J, d’Ambrosio Alfano FR, Palella BI (2017) Evaluation of the metabolic rate based on the recording of the heart rate. Ind Health 55, 219–32. · DOI
  11. 26) Ainsworth BE, Haskell WL, Whitt MC, Irwin ML, Swartz AM, Strath SJO, O’Brien WL, Bassett DR Jr, Schmitz KH, Emplaincourt PO, Jacobs DR Jr, Leon AS (2000) Compendium of physical activities: an update of activity codes and MET intensities. Med Sci Sports Exerc 32 Suppl, S498–504. · DOI · Paper page
  12. 28) Bland JM, Altman DG (2002) Statistics Notes: validating scales and indexes. BMJ 324, 606–7. · DOI · Paper page
  13. 29) Ramanathan NL (1964) A new weighting system for mean surface temperature of the human body. J Appl Physiol 19, 531–3. · DOI · Paper page
  14. 30) Poulianiti KP, Havenith G, Flouris AD (2019) Metabolic energy cost of workers in agriculture, construction, manufacturing, tourism, and transportation industries. Ind Health 57, 283–305. · DOI · Paper page
  15. 31) Du Bois D, Du Bois EF (1916) Clinical calorimetry: tenth paper a formula to estimate the approximate surface area if height and weight be known. Archives of internal medicine, 17, 863–871. · DOI · Paper page
  16. 32) Lundgren-Kownacki K, Martínez N, Johansson B, Psikuta A, Annaheim S, Kuklane K (2017) Human responses in heat - comparison of the Predicted Heat Strain and the Fiala multi-node model for a case of intermittent work. J Therm Biol 70 Pt A, 45–52. · DOI

Cited by

See all 40

Metadata

Authors
IOANNOU, L. G., TSOUTSOUBI, L., MANTZIOS, K., & FLOURIS, A. D.
Venue
Industrial Health
Published
2019
Volume
57
Issue
6
Pages
711-720
ISSN
  • 0019-8366 (ISSN-L)
  • 1880-8026
OpenAlex
W2923131053
Cited by
40
References
6
FWCI
2.57
Type
journal article
Language
en
Open access
diamond

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A free software to predict heat strain according to the ISO 7933:2018. https://app.cochat.ai/papers/10.2486/indhealth.2018-0216
The paper
IOANNOU, L. G., TSOUTSOUBI, L., MANTZIOS, K., & FLOURIS, A. D. (2019). A free software to predict heat strain according to the ISO 7933:2018. Industrial Health. https://doi.org/10.2486/indhealth.2018-0216

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.