Protection against Impact with the Ground Using Wearable Airbags
Open accessAbstract
Incidental falls from heights, falls on the same level caused by slipping or tripping, and falls from wheelchair overturns are commonplace phenomena, associated with serious injuries from impact with the ground. A wearable airbag device is a countermeasure applicable to all these types of incidents. Three types of wearable airbag systems were developed and evaluated: for protection against falls from heights (Type-1), against wheelchair overturns (Type-2), and against falls on the same level (Type-3). The systems consist of an airbag, sensor, inflator, and jacket. The sensor detects the fall and the airbag inflates to protect the user. Fall tests using dummies with/without the airbags demonstrated the effectiveness of these devices. In the experiments with system Type-1, for fall heights of less than 2m, the airbags reduced the impact acceleration, and the Head Injury Criterion (HIC) values were under 1,000, the auto-crash test requirement. However, there are limits to the amount of protection afforded: in Type-1, the airbag can protect only the back of the head.; in Types-2 and 3, the fall height of the center of gravity is lower than 2m, and there is some margin of extra protective resource, which can be used to extend the protected area.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Airbag systems rely on wearable accelerometers and gyroscopes to trigger inflation when a fall is detected.
“These systems rely upon wearable accelerometers and gyroscopes to trigger the inflation of the airbag when a fall is detected.”
From A review of wearable sensors and systems with application in rehabilitation (2012) · cites this paper as [80]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Biomechanics of impact injury and injury tolerances of the head-neck complex
Backaitis, S. H. (1993) · Society of Automotive Engineers eBooks · Cited by 34 · see citing works
Biomechanics of impact injury and injury tolerances of the extremities
Backaitis, S. H. (1996) · Society of Automotive Engineers eBooks · Cited by 8 · see citing works
Analysis of Backward Falls Caused by Accelerated Floor Movements Using a Dummy
Nagata, H., & Hisato, O. H. N. O. (2007) · Industrial Health · doi:10.2486/indhealth.45.462 · Cited by 8 · see citing works
Backaitis, S. H. (1995) · Society of Automotive Engineers eBooks · Cited by 5 · see citing works
Flagged first, then by citations
Research works printed but not linked: 5
- Fukaya K (2003) Shock absorption performance of fall protection airbag system. In: Proceedings of the XVth Triennial Congress of the International Ergonomics Association and The 7th Joint Conference of Ergonomics Society of Korea/Japan Ergonomics Society, (CD-ROM), The Ergonomics Society of Korea, Soul.
- Fukaya K (2006) The Shock absorption performance of an airbag system for fall of wheelchair. In: The Proceedings IEA2006 Congress, (CD-ROM), Elsevier Ltd, Maastricht.
- Fukaya K, Nagata H, Yoshimura T, Tanaka O, Uchida M (2007) Development of Wearable airbags for falls on the level floors, International Conference on Slips, Trips, and Falls 2007, 93-7, Massachusetts.
- Backaitis SH (Ed.) (1994) Biomechanics of impact injuries and injury tolerances of the thoax-shoulder com- plex, Society of Automotive Engineers, Book No.PT- 45, Pennsylvania.
- Fukaya K (2002) Safety measures for fall protection. Reports of the National Institute of Industrial Safety, NIIS-RR-2002 (2003), 95-104 (in Japanese).
Cited by
Sorted by citations
A review of wearable sensors and systems with application in rehabilitation
Patel, S., Park, H., Bonato, P., Chan, L., & Rodgers, M. (2012) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-9-21 · Cited by 2,396 · see citing works
- Authors
- FUKAYA, K., & UCHIDA, M.
- Affiliations
- National Institute for Occupational Safety and Health (US)
- Venue
- Industrial Health
- Published
- 2008
- Volume
- 46
- Issue
- 1
- Pages
- 59-65
- ISSN
- 0019-8366 (ISSN-L)
- 1880-8026
- OpenAlex
- W1980101398
- Cited by
- 42
- References
- 4
- Citations by year
- 2026: 2 · 2025: 2 · 2024: 4 · 2023: 2 · 2022: 7 · 2021: 2 · 2020: 3 · 2018: 1 · 2017: 1 · 2015: 2 · 2014: 3 · 2013: 4 · 2012: 2
- FWCI
- 2.14
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Industrial Health (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Automotive and Human Injury Biomechanics
- Health Sciences › Health Professions › Physical Therapy, Sports Therapy and Rehabilitation › Balance, Gait, and Falls Prevention
- Health Sciences › Health Professions › Radiological and Ultrasound Technology › Occupational Health and Safety Research
- Keywords
- fall protection, fall from height, impact acceleration, head injury criterion, protective clothing, injury prevention
- MeSH terms
- Accidental Falls, Humans, Protective Clothing, Wheelchairs, Wounds and Injuries, Air Bags
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review