The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Use of piezoelectric actuators as elements of intelligent structures
Abstract
This work presents the analytic and experimental development of piezoelectric actuators as elements of intelligent structures, i.e., structures with highly distributed actuators, sensors, and processing networks. Static and dynamic analytic models are derived for segmented piezoelectric actuators that are either bonded to an elastic substructure or embedded in a laminated composite. These models lead to the ability to predict, a priori, the response of the structural member to a command voltage applied to the piezoelectric and give guidance as to the optimal location for actuator placement. A scaling analysis is performed to demonstrate that the effectiveness of piezoelectric actuators is independent of the size of the structure and to evaluate various piezoelectric materials based on their effectiveness in transmitting strain to the substructure. Three test specimens of cantilevered beams were constructed: an aluminum beam with surface-bonded actuators, a glass/epoxy beam with embedded actuators, and a graphite/epoxy beam with embedded actuators. The actuators were used to excite steady-state resonant vibrations in the cantilevered beams. The response of the specimens compared well with those predicted by the analytic models. Static tensile tests performed on glass/epoxy laminates indicated that the embedded actuator reduced the ultimate strength of the laminate by 20%, while not significantly affecting the global elastic modulus of the specimen.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Introduction to Composite Materials
Tsai, S. W., & Hahn, H. T. (2018) · Routledge eBooks · doi:10.1201/9780203750148 · Cited by 2,024
Elements of vibration analysis
Meirovitch, L. (1975) · Andalas University Repository (Andalas University) · Cited by 1,768
Distributed piezoelectric-polymer active vibration control of a cantilever beam
Bailey, T., & Hubbard, J. E. (1985) · Journal of Guidance, Control, and Dynamics · doi:10.2514/3.20029 · Cited by 1,337
Active control of flexible systems
Balas, M. J. (1978) · Journal of Optimization Theory and Applications · doi:10.1007/bf00932903 · Cited by 720
Cited by
A Review of Power Harvesting from Vibration Using Piezoelectric Materials
Sodano, H. A., Inman, D. J., & Park, G. (2004) · The Shock and Vibration Digest · doi:10.1177/0583102404043275 · Cited by 1,361
Giurgiutiu, V. (2005) · Journal of Intelligent Material Systems and Structures · doi:10.1177/1045389x05050106 · Cited by 942
Out-of-Plane Piezoelectricity and Ferroelectricity in Layered α-In2Se3 Nanoflakes
Zhou, Y., Wu, D., Zhu, Y., Cho, Y., He, Q., Yang, X., Herrera, K., Chu, Z., Han, Y., Downer, M. C., et al. (2017) · Nano Letters · doi:10.1021/acs.nanolett.7b02198 · Cited by 936
Liang, C., Sun, F. P., & Rogers, C. A. (1994) · Journal of Intelligent Material Systems and Structures · doi:10.1177/1045389x9400500102 · Cited by 790
Fundamental Understanding of Piezoelectric Strain Sensors
Sirohi, J., & Chopra, I. (2000) · Journal of Intelligent Material Systems and Structures · doi:10.1106/8bfb-gc8p-xq47-ycq0 · Cited by 777
Metadata
- Authors
- Crawley, E. F., & de Luis, J.
- Venue
- AIAA Journal
- Published
- 1987-10
- Volume
- 25
- Issue
- 10
- Pages
- 1373-1385
- ISSN
- 0001-1452 (ISSN-L)
- 1533-385X
- OpenAlex
- W2019442299
- Cited by
- 2,602
- References
- 4
- FWCI
- 55.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.