The Interrater Reliability of 4 Clinical Tests Used to Assess Individuals With Musculoskeletal Hip Pain
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
STUDY DESIGN: Descriptive and reliability study. OBJECTIVES: To evaluate the interrater reliability of the FABER test, flexion-internal rotation-adduction impingement test, log roll test, and the palpation of the greater trochanter for tenderness. BACKGROUND: Clinical examination for individuals with musculoskeletal hip pain is believed to provide critical diagnostic information. However, there is very limited information in the literature on the reproducibility of examination techniques for the hip region. METHODS AND MEASURES: Seventy subjects were evaluated prospectively by an orthopaedic surgeon and physical therapist. Subjects had a mean age of 42 years (range 18-76 years; SD 15.4) and included 32 (46%) females and 38 (54%) males. Subject diagnoses were as follows: degenerative joint disease (n=27 [39% of subjects]), labral tear (n=35 [50% of subjects]), femoroacetabular impingement (n=48 [69% of subjects]), capsular laxity (n=28 [40% of subjects]), trochanteric bursitis (n=29 [41% of subjects]), iliopsoas tendonitis (n=10 [14% of subjects]), and adductor strain (n=2 [3% of subjects)]. Subjects could have more than 1 diagnosis. Kappa, prevalence indexes, bias indexes, and maximal attainable kappa were calculated. RESULTS: Kappa (kappa) coefficients with 95% confidence intervals (CI) were as follows: FABER test kappa was 0.63 (95% CI: 0.43-0.83); flexion-internal rotation-adduction impingement test kappa was 0.58 (95% CI: 0.29-0.87); log roll test kappa was 0.61 (95% CI: 0.41-0.81); and greater trochanteric tenderness kappa was 0.66 (95% CI: 0.48-0.84). Bias indexes were low (0.06-0.08) for all 4 tests while prevalence indexes were low (0.03-0.37) for 3 of the 4 tests. The flexion-internal rotation-adduction impingement test had a high prevalence index (0.76), with a higher proportion of positive tests. CONCLUSION: The kappa values for the FABER test, log roll test, and assessment of greater trochanteric tenderness were greater than 0.40 (fair level of agreement) at a 95% confidence level. The low reliability obtained for the flexion-internal rotation-adduction impingement test may be related to a prevalence concern.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The kappa statistic in reliability studies: use, interpretation, and sample size requirements
Sim, J., & Wright, C. C. (2005) · Physical Therapy · doi:10.1093/ptj/85.3.257 · Cited by 4,093
Byrt, T., Bishop, J., & Carlin, J. B. (1993) · Journal of Clinical Epidemiology · doi:10.1016/0895-4356(93)90018-v · Cited by 2,179
Cited by
Clinical Presentation of Patients with Symptomatic Anterior Hip Impingement
Clohisy, J. C., Knaus, E. R., Hunt, D. M., Lesher, J. M., Harris-Hayes, M., & Prather, H. (2009) · Clinical Orthopaedics & Related Research · doi:10.1007/s11999-008-0680-y · Cited by 461
Myers, C. A., Register, B. C., Lertwanich, P., Ejnisman, L., Pennington, W. W., Giphart, J. E., LaPrade, R. F., & Philippon, M. J. (2011) · The American Journal of Sports Medicine · doi:10.1177/0363546511412161 · Cited by 360
Allen, D., Beaulé, P. E., Ramadan, O., & Doucette, S. (2009) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.91b5.22028 · Cited by 306
Martin, H. D., Kelly, B. T., Leunig, M., Philippon, M. J., Clohisy, J. C., Martin, R. L., Sekiya, J. K., Pietrobon, R., Mohtadi, N. G., Sampson, T. G., et al. (2010) · Arthroscopy: The Journal of Arthroscopic & Related Surgery · doi:10.1016/j.arthro.2009.07.015 · Cited by 190
Self-citationBagwell, J. J., Snibbe, J., Gerhardt, M., & Powers, C. M. (2016) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2015.09.016 · Cited by 115
“Specifically, subjects were excluded if they had a positive log roll test (Martin and Sekiya, 2008), greater than 5 cm asymmetry between sides with the Flexion ABduction External Rotation test (FABER test) (Philippon et al.”
MethodA painful squat test provides limited diagnostic utility in CAM-type femoroacetabular impingement
Ayeni, O., Chu, R., Hetaimish, B., Nur, L., Simunovic, N., Farrokhyar, F., Bedi, A., & Bhandari, M. (2014) · Knee Surgery Sports Traumatology Arthroscopy · doi:10.1007/s00167-013-2668-8 · Cited by 29
The influence of squat kinematics and cam morphology on acetabular stress
Bagwell, J. J., & Powers, C. M. (2017) · Arthroscopy · doi:10.1016/j.arthro.2017.03.018 · Cited by 22
Metadata
- Authors
- Martin, R. L., & Sekiya, J. K.
- Venue
- Journal of Orthopaedic & Sports Physical Therapy
- Published
- 2008-02
- Volume
- 38
- Issue
- 2
- Pages
- 71-77
- ISSN
- 0190-6011 (ISSN-L)
- 1938-1344
- OpenAlex
- W2093752278
- Cited by
- 116
- References
- 2
- FWCI
- 7.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.