Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 510

The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.

Reliability, Standard Error, and Minimum Detectable Change of Clinical Pressure Pain Threshold Testing in People With and Without Acute Neck Pain

Walton, David, MacDermid, Joy, Nielson, Warren, Teasell, Robert, Chiasson, Marco, Brown, Lauren·2011·Journal of Orthopaedic & Sports Physical Therapy

Abstract

Study Design: Clinical measurement. Objectives: To evaluate the intrarater, interrater, and test-retest reliability of an accessible digital algometer, and to determine the minimum detectable change in normal healthy individuals and a clinical population with neck pain. Background: Pressure pain threshold testing may be a valuable assessment and prognostic indicator for people with neck pain. To date, most of this research has been completed using algometers that are too resource intensive for routine clinical use. Methods: Novice raters (physiotherapy students or clinical physiotherapists) were trained to perform algometry testing over 2 clinically relevant sites: the angle of the upper trapezius and the belly of the tibialis anterior. A convenience sample of normal healthy individuals and a clinical sample of people with neck pain were tested by 2 different raters (all participants) and on 2 different days (healthy participants only). Intraclass correlation coefficient (ICC), standard error of measurement, and minimum detectable change were calculated. Results: A total of 60 healthy volunteers and 40 people with neck pain were recruited. Intrarater reliability was almost perfect (ICC = 0.94–0.97), interrater reliability was substantial to near perfect (ICC = 0.79–0.90), and test-retest reliability was substantial (ICC = 0.76–0.79). Smaller change was detectable in the trapezius compared to the tibialis anterior. Conclusions: This study provides evidence that novice raters can perform digital algometry with adequate reliability for research and clinical use in people with and without neck pain. J Orthop Sports Phys Ther 2011;41(9):644–650. doi:10.2519/jospt.2011.3666

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2519/jospt.2011.3666

Cites

28 of 28 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 28 references

Cited by

See all 510

Metadata

Authors
Walton, D., MacDermid, J., Nielson, W., Teasell, R., Chiasson, M., & Brown, L.
Venue
Journal of Orthopaedic & Sports Physical Therapy
Published
2011-09
Volume
41
Issue
9
Pages
644-650
ISSN
  • 0190-6011 (ISSN-L)
  • 1938-1344
OpenAlex
W1995657892
Cited by
510
References
28
FWCI
8.35
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Reliability, Standard Error, and Minimum Detectable Change of Clinical Pressure Pain Threshold Testing in People With and Without Acute Neck Pain. https://app.cochat.ai/papers/10.2519/jospt.2011.3666
The paper
Walton, D., MacDermid, J., Nielson, W., Teasell, R., Chiasson, M., & Brown, L. (2011). Reliability, Standard Error, and Minimum Detectable Change of Clinical Pressure Pain Threshold Testing in People With and Without Acute Neck Pain. Journal of Orthopaedic & Sports Physical Therapy. https://doi.org/10.2519/jospt.2011.3666

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.