The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
The Functional Movement Screen: A Reliability Study
Abstract
Study Design: Reliability study. Objectives: To determine intrarater test-retest and interrater reliability of the Functional Movement Screen (FMS) among novice raters. Background: The FMS is used by various examiners to assess movement and predict time-loss injuries in diverse populations (eg, youth to professional athletes, firefighters, military service members) of active participants. Unfortunately, critical analysis of the reliability of the FMS is currently limited to 1 sample of active college-age participants. Methods: Sixty-four active-duty service members (mean ± SD age, 25.2 ± 3.8 years; body mass index, 25.1 ± 3.1 kg/m 2 ) without a history of injury were enrolled. Participants completed the 7 component tests of the FMS in a counterbalanced order. Each component test was scored on an ordinal scale (0 to 3 points), resulting in a composite score ranging from 0 to 21 points. Intrarater test-retest reliability was assessed between baseline scores and those obtained with repeated testing performed 48 to 72 hours later. Interrater reliability was based on the assessment from 2 raters, selected from a pool of 8 novice raters, who assessed the same movements on day 2 simultaneously. Descriptive statistics, weighted kappa (κ w), and percent agreement were calculated on component scores. Intraclass correlation coefficients (ICCs), standard error of the measurement, minimal detectable change (MDC 95), and associated 95% confidence intervals (CIs) were calculated on composite scores. Results: The average ± SD score on the FMS was 15.7 ± 0.2 points, with 15.6% (n = 10) of the participants scoring less than or equal to 14 points, the recommended cutoff for predicting time-loss injuries. The intrarater test-retest and interrater reliability of the FMS composite score resulted in an ICC 3,1 of 0.76 (95% CI: 0.63, 0.85) and an ICC 2,1 of 0.74 (95% CI: 0.60, 0.83), respectively. The standard error of the measurement of the composite test was within 1 point, and the MDC 95 values were 2.1 and 2.5 points on the 21-point scale for interrater and intrarater reliability, respectively. The interrater agreement of the component scores ranged from moderate to excellent (κ w = 0.45–0.82). Conclusion: Among novice raters, the FMS composite score demonstrated moderate to good interrater and intrarater reliability, with acceptable levels of measurement error. The measures of reliability and measurement error were similar for both intrarater reliability that repeated the assessment of the movement patterns over a 48- to-72-hour period and interrater reliability that had 2 raters assess the same movement pattern simultaneously. The interrater agreement of the FMS component scores was good to excellent for the push-up, quadruped, shoulder mobility, straight leg raise, squat, hurdle, and lunge. Only 15.6% (n = 10) of the participants were identified to be at risk for injury based on previously published cutoff values. J Orthop Sports Phys Ther 2012;42(6):530–540, Epub 14 May 2012. doi:10.2519/jospt.2012.3838
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Foundations of Clinical Research: Applications to Practice,
(2002) · Survey of Ophthalmology · doi:10.1016/s0039-6257(02)00362-4 · Cited by 9,489
Mandelbaum, B. R., Silvers, H. J., Watanabe, D. S., Knarr, J. F., Thomas, S. D., Griffin, L. Y., Kirkendall, D. T., & Garrett, W. (2005) · The American Journal of Sports Medicine · doi:10.1177/0363546504272261 · Cited by 1,136
NEUROMUSCULAR TRAINING IMPROVES PERFORMANCE AND LOWER-EXTREMITY BIOMECHANICS IN FEMALE ATHLETES
MYER, G. D., FORD, K. R., PALUMBO, O. P., & HEWETT, T. E. (2005) · Journal of Strength and Conditioning Research · doi:10.1519/00124278-200502000-00010 · Cited by 753
Running Injuries: A Review of the Epidemiological Literature
van Mechelen, W. (1992) · Sports Medicine · doi:10.2165/00007256-199214050-00004 · Cited by 521
Pre-participation screening: the use of fundamental movements as an assessment of function - part 1.
Cook, G., Burton, L., & Hoogenboom, B. (2006) · PubMed · Cited by 474
Myer, G. D., Ford, K. R., McLean, S. G., & Hewett, T. E. (2006) · The American Journal of Sports Medicine · doi:10.1177/0363546505281241 · Cited by 466
Relationship Between Core Stability, Functional Movement, and Performance
Okada, T., Huxel, K. C., & Nesser, T. W. (2011) · Journal of Strength and Conditioning Research · doi:10.1519/jsc.0b013e3181b22b3e · Cited by 430
MYER, G. D., FORD, K. R., BRENT, J. L., & HEWETT, T. E. (2006) · Journal of Strength and Conditioning Research · doi:10.1519/00124278-200605000-00019 · Cited by 429
Use of a functional movement screening tool to determine injury risk in female collegiate athletes.
Chorba, R. S., Chorba, D. J., Bouillon, L. E., Overmyer, C. A., & Landis, J. A. (2010) · Europe PMC (PubMed Central) · Cited by 428
Pre-participation screening: the use of fundamental movements as an assessment of function - part 2.
Cook, G., Burton, L., & Hoogenboom, B. (2006) · PubMed · Cited by 427
Cited by
Y-Balance Test: A Reliability Study Involving Multiple Raters
Shaffer, S. W., Teyhen, D. S., Lorenson, C. L., Warren, R. L., Koreerat, C. M., Straseske, C. A., & Childs, J. D. (2013) · Military Medicine · doi:10.7205/milmed-d-13-00222 · Cited by 484
Self-citationBonazza, N. A., Smuin, D., Onks, C. A., Silvis, M. L., & Dhawan, A. (2017) · The American Journal of Sports Medicine · doi:10.1177/0363546516641937 · Cited by 329
Development of a screening protocol to identify individuals with dysfunctional breathing
Kiesel, K., Rhodes, T., Mueller, J., Waninger, A., & Butler, R. (2017) · International Journal of Sports Physical Therapy · doi:10.26603/ijspt20170774 · Cited by 42
Sensor Data Required for Automatic Recognition of Athletic Tasks Using Deep Neural Networks
Clouthier, A. L., Ross, G. B., & Graham, R. B. (2020) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2019.00473 · Cited by 29
The Correlation between Motor Skill Proficiency and Academic Performance in High School Students
Ramos-Campo, D. J., & Clemente-Suárez, V. J. (2024) · Behavioral Sciences · doi:10.3390/bs14070592 · Cited by 19
Metadata
- Authors
- Teyhen, D. S., Shaffer, S. W., Lorenson, C. L., Halfpap, J. P., Donofry, D. F., Walker, M. J., Dugan, J. L., & Childs, J. D.
- Venue
- Journal of Orthopaedic & Sports Physical Therapy
- Published
- 2012-06
- Volume
- 42
- Issue
- 6
- Pages
- 530-540
- ISSN
- 0190-6011 (ISSN-L)
- 1938-1344
- OpenAlex
- W1967311919
- Cited by
- 333
- References
- 27
- FWCI
- 27.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Functional Movement Screen: A Reliability Study. https://app.cochat.ai/papers/10.2519/jospt.2012.3838
- The paper
- Teyhen, D. S., Shaffer, S. W., Lorenson, C. L., Halfpap, J. P., Donofry, D. F., Walker, M. J., Dugan, J. L., & Childs, J. D. (2012). The Functional Movement Screen: A Reliability Study. Journal of Orthopaedic & Sports Physical Therapy. https://doi.org/10.2519/jospt.2012.3838
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.