Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 282

The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.

Evaluation of a Body-Worn Sensor System to Measure Physical Activity in Older People With Impaired Function

Taraldsen, Kristin, Askim, Torunn, Sletvold, Olav, Einarsen, Elin Kristin, Grüner Bjåstad, Karianne, Indredavik, Bent, Helbostad, Jorunn Laegdheim · 2011 · Physical Therapy

Abstract

BACKGROUND: There is limited information on reliable and valid measures of physical activity in older people with impaired function. OBJECTIVE: This study was conducted to compare the accuracy of single-axis accelerometers in recognizing postures and transitions and step counting with the accuracy of video recordings in people with stroke (n=14), older inpatients (n=14), people with hip fracture (n=8), and a reference group of 10 adults who were healthy. DESIGN: This was a cross-sectional study, evaluating the concurrent validity of small body-worn accelerometers against video observations as the criterion measure. METHODS: Activity data were collected from 3 sensors (activPAL) attached to the thighs and the sternum and from registration of the same activities from video recordings. Participants performed a test protocol of in-bed, transfer, and walking activities. RESULTS: The sensor system was highly accurate in classifying lying, sitting, and standing positions (100%) and in recognizing transitions from lying to sitting positions and from sitting to standing positions (100%). Placement of a sensor on the nonaffected leg resulted in less underestimation of step counts than placement on the affected leg. Still, the sensor system underestimated step counts during walking, especially at slow walking speeds (≤0.47 m/s) (limits of agreement=-2.01 to 16.54, absolute percent error=40.31). LIMITATIONS: The study was performed in a controlled setting and not during the natural performance of activities. CONCLUSIONS: The activPAL sensor system provides valid measures of postures and transitions in older people with impaired walking ability. Step counting needs to be improved for the sensor system to be acceptable for this population, especially at slow walking speeds.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2522/ptj.20100159

Cites

22 of 22 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 22 references

Cited by

See all 282

Metadata

Authors
Taraldsen, K., Askim, T., Sletvold, O., Einarsen, E. K., Grüner Bjåstad, K., Indredavik, B., & Helbostad, J. L.
Venue
Physical Therapy
Published
2011-02-01
Volume
91
Issue
2
Pages
277-285
ISSN
  • 0031-9023 (ISSN-L)
  • 1538-6724
OpenAlex
W2154194639
Cited by
282
References
22
FWCI
20.36
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Evaluation of a Body-Worn Sensor System to Measure Physical Activity in Older People With Impaired Function. https://app.cochat.ai/papers/10.2522/ptj.20100159
The paper
Taraldsen, K., Askim, T., Sletvold, O., Einarsen, E. K., Grüner Bjåstad, K., Indredavik, B., & Helbostad, J. L. (2011). Evaluation of a Body-Worn Sensor System to Measure Physical Activity in Older People With Impaired Function. Physical Therapy. https://doi.org/10.2522/ptj.20100159

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.