Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 46 of the 49 references it cites were found in a registry or an index; 14 of the 28 sources its claims cite were checked for support.

Intrapatient variability of 18F-FDG uptake in normal tissues

Open access
Sayed, Mohamed Hosny Mohamed, Abdelnaim, Aya KM, Mohamadien, Nsreen RA · 2022 · Journal of Clinical Imaging Science

Abstract

Retrospective study of repeat FDG PET/CT scans assessing variability in normal tissue SUVmax and confounding factors including blood glucose and BMI.

Overview

CoChat Summary

## TL;DR

This retrospective study of 167 cancer patients (334 PET/CT scans) compared test/retest variability of normal-tissue 18F-FDG uptake and found that the liver, muscle, and spleen were the most stable candidate reference tissues. Among these, spleen and muscle were judged more optimal than liver because their SUVmax was consistently associated only with injected dose, while liver SUVmax also depended on uptake duration.

## Key findings

  • In 167 cancer patients with two scans on average 152 ± 68 days apart, the SUVmax of the lungs and heart differed significantly between studies (lung: 0.67 ± 0.29 vs 0.75 ± 0.37, P = 0.003; heart: 6.6 ± 5.6 vs 7.7 ± 5.7, P = 0.024), while other normal tissues did not differ significantly.
  • Brain SUVmax showed the clearest glucose effect: in diabetic patients it had a moderate negative correlation with blood glucose in the first study (r = −0.537, P = 0.001), and in the whole cohort it also showed weak negative correlations with blood glucose in both studies (r = −0.245, P < 0.001; r = −0.232, P = 0.003).
  • Liver SUVmax had a moderate positive correlation with BMI in both studies (r = 0.416, P < 0.001; r = 0.453, P < 0.001), and liver plus blood pool showed moderate negative correlation with uptake time in the first study only (liver r = −0.405, P < 0.001; blood pool r = −0.409, P < 0.001).
  • In multivariate analysis adjusted for age, sex, BMI, and injected dose, liver SUVmax was consistently affected by injected dose and uptake duration on both occasions; spleen and muscle were consistently affected only by injected dose.

## Methods

  • Retrospective review of 334 18F-FDG PET/CT scans from 167 cancer patients, including 38 diabetics; each patient had two studies, with a mean interval of 152 ± 68 days.
  • Ten matched VOIs were drawn in normal tissues: brain, tonsil, blood pool, heart, lung, liver, spleen, bone marrow, fat, and iliopsoas muscle, avoiding pathology; SUVmax was measured on both occasions.
  • Statistical analysis used t-tests, Pearson correlations, and multivariate analysis adjusted for age, sex, BMI, injected dose, and uptake duration.

## Limitations

  • The paper explicitly states the study was retrospective and used SUVmax only according to body weight, without considering other SUV calculation methods.
  • It states a larger prospective study is needed to verify the effects of high blood glucose and other confounders; this implies limited generalizability and need for confirmation.
  • The text makes evident that disease burden was not included in the analysis because the authors assumed it did not affect normal-tissue uptake, which they note as another potential limitation.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.25259/jcis_23_2022

Cites

46 of 46 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Figures

Figure 1: 18F-FDG PET/CT scan of a 60-year-old female with breast cancer. (a) Transaxial coregistered PET/CT, (b) Coronal coregistered PET/CT and (c) Sagittal coregistered PET/CT images demonstrate placement of the standard three-dimensional volume of interest for mediastinal blood pool (arrowed green circle and rectangles). (d) Transaxial PET/CT fusion, (e) Coronal PET/CT fusion and (f) Sagittal PET/CT fusion images demonstrate placement of the standard three-dimensional volume of interest for liver (arrowed green circles).
Figure 1: 18F-FDG PET/CT scan of a 60-year-old female with breast cancer. (a) Transaxial coregistered PET/CT, (b) Coronal coregistered PET/CT and (c) Sagittal coregistered PET/CT images demonstrate placement of the standard three-dimensional volume of interest for mediastinal blood pool (arrowed green circle and rectangles). (d) Transaxial PET/CT fusion, (e) Coronal PET/CT fusion and (f) Sagittal PET/CT fusion images demonstrate placement of the standard three-dimensional volume of interest for liver (arrowed green circles).CC BY-NC-SA · PubMed Central
Figure 2: 18F-FDG PET/CT scan of a 60-year-old female with breast cancer. Transaxial coregistered PET/CT images demonstrate placement of the standard three-dimensional volume of interest for normal tissues (arrowed green circles) including lung, spleen and muscle (left column), heart, bone marrow, fat (middle column), brain and tonsil (right column).
Figure 2: 18F-FDG PET/CT scan of a 60-year-old female with breast cancer. Transaxial coregistered PET/CT images demonstrate placement of the standard three-dimensional volume of interest for normal tissues (arrowed green circles) including lung, spleen and muscle (left column), heart, bone marrow, fat (middle column), brain and tonsil (right column).CC BY-NC-SA · PubMed Central

Verification

Claims the paper makes

7 Valid · 1 Not valid · 5 Not checked · 53 Own results and interpretations

32 more claims

Create a free account to see all 66 claims and every source verdict.

See all claims — free account
  • Probably not a substantial claim. 12
  • It may state two separate claims as one. 23

Create a free account to see these claims.

Citations

Cites

Show all 49 references

Cited by

See all 2

Metadata

Authors
Sayed, M. H. M., Abdelnaim, A. K., & Mohamadien, N. R.
Affiliations
Assiut University (EG)
Corresponding author
Sayed, Mohamed Hosny Mohamed
Venue
Journal of Clinical Imaging Science
Published
2022-07-08
Volume
12
Pages
37
ISSN
  • 2156-5597 (ISSN-L)
  • 2156-7514
OpenAlex
W4284898578
Cited by
2
References
49
Citations by year
2024: 2
FWCI
0.28
Type
journal article
Language
en
Open access
Licence
cc-by-nc-sa
Locations
  • Journal of Clinical Imaging Science (publishedVersion, cc-by-nc-sa)
  • PubMed Central (publishedVersion, cc-by-nc-sa)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Lung Cancer Diagnosis and Treatment
  • Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
Keywords
18F-FDG, standardized uptake value, intrapatient variability, reference tissue, test-retest stability, serum glucose, diabetes mellitus, body mass index, liver, spleen, muscle, blood pool, PET/CT

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

The claim verdicts this report counts are experimental: their accuracy is not yet measured.

A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Cited sources are checked with a language model’s help (gpt-6-sol).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Intrapatient variability of 18F-FDG uptake in normal tissues. https://app.cochat.ai/papers/10.25259/jcis_23_2022
The paper
Sayed, M. H. M., Abdelnaim, A. K., & Mohamadien, N. R. (2022). Intrapatient variability of 18F-FDG uptake in normal tissues. Journal of Clinical Imaging Science. https://doi.org/10.25259/jcis_23_2022

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.