MALDI-TOF MS in lipidomics
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
So far, matrix-assisted laser desorption and ionization time-of-flight mass spectrometry (MALDI-TOF MS) seemed to be nearly a synonym for protein analysis. However, there is growing evidence that this technique is also an useful tool in lipid analysis and lipidomics because of its fast, simple and convenient performance allowing to record mass spectra of cells, crude tissue or body fluid extracts or even intact tissue slices in a few minutes. On the negative side, however, the reproducibility of MALDI-TOF mass spectra depends significantly on the homogeneity of the co-crystals between matrix and analyte and different lipid classes are detected with different sensitivities. This is especially important because lipids with quaternary ammonia groups (e.g., GPCho) may prevent the detection of other lipid classes (e.g., GPEtn). This review starts with a short overview on traditional methods of lipid analysis with the focus on mass spectrometric methods and compares MALDI-TOF MS with other important ionization techniques. Afterwards, some landmarks in the development of MALDI-TOF MS will be introduced and some important examples in the field of tissue and body fluid lipid analysis will be discussed. This review ends with a short outlook and summary focusing on the advantages and drawbacks of MALDI-TOF MS in lipidomics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A RAPID METHOD OF TOTAL LIPID EXTRACTION AND PURIFICATION
Bligh, E. G., & Dyer, W. J. (1959) · Canadian Journal of Biochemistry and Physiology · doi:10.1139/o59-099 · Cited by 54,751
Han, X., & Gross, R. W. (2003) · Journal of Lipid Research · doi:10.1194/jlr.r300004-jlr200 · Cited by 914
New insights on oxidative stress in the artery wall
STOCKER, R., & KEANEY, J. F. (2005) · Journal of Thrombosis and Haemostasis · doi:10.1111/j.1538-7836.2005.01370.x · Cited by 188
Cited by
Hsu, F.-F., & Turk, J. (2009) · Journal of Chromatography B · doi:10.1016/j.jchromb.2009.02.033 · Cited by 346
An update of MALDI-TOF mass spectrometry in lipid research
Fuchs, B., Süß, R., & Schiller, J. (2010) · Progress in Lipid Research · doi:10.1016/j.plipres.2010.07.001 · Cited by 324
Self-citationHan, X., Yang, K., & Gross, R. W. (2008) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.3595 · Cited by 190
Han, X. (2007) · Journal of Neurochemistry · doi:10.1111/j.1471-4159.2007.04708.x · Cited by 101
“Among these analytical techniques, MS has played a leading role in lipid characterization, identification, and quantitation (Byrdwell 2003; Griffiths 2003; Han and Gross 2003, 2005a; Pulfer and Murphy 2003; Hsu and Turk 2005; Schiller et al. 2007).”
MethodCarrasco-Pancorbo, A., Navas-Iglesias, N., & Cuadros-Rodríguez, L. (2009) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2008.12.005 · Cited by 100
Schröter, J., & Schiller, J. (2016) · Oxidative Medicine and Cellular Longevity · doi:10.1155/2016/8386362 · Cited by 51
“The same applies if lipids with different headgroups and different tendencies to form a positive charge are investigated [206].”
BackgroundSelf-citation
Metadata
- Authors
- Schiller, J.
- Venue
- Frontiers in Bioscience
- Publisher
- IMR Press
- Published
- 2007
- Volume
- 12
- Issue
- 1
- Pages
- 2568
- ISSN
- 1093-4715 (ISSN-L)
- 1093-9946
- DOI
- 10.2741/2255
- OpenAlex
- W1993147562
- Cited by
- 162
- References
- 3
- FWCI
- 7.10
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.