New Technologies for Construction of Medium-Rise Buildings in Seismic Regions: The XLAM Case
The DOI matches its Crossref record.
Abstract
This paper reports on the outcomes of an experimental test performed on a full-scale building constructed using innovative technology. The experimental results are compared with the outcomes of a numerical analysis with the aim to derive the behaviour factor q used in a simplified elastic design of the building under seismic actions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
SOFIE project – 3D shaking table test on a seven‐storey full‐scale cross‐laminated timber building
Ceccotti, A., Sandhaas, C., Okabe, M., Yasumura, M., Minowa, C., & Kawai, N. (2013) · Earthquake Engineering & Structural Dynamics · doi:10.1002/eqe.2309 · Cited by 388
Self-citationCyclic Behavior of CLT Wall Systems: Experimental Tests and Analytical Prediction Models
Gavric, I., Fragiacomo, M., & Ceccotti, A. (2015) · Journal of Structural Engineering · doi:10.1061/(asce)st.1943-541x.0001246 · Cited by 272
Self-citationPerformance of a 2-Story CLT House Subjected to Lateral Loads
Popovski, M., & Gavric, I. (2016) · Journal of Structural Engineering · doi:10.1061/(asce)st.1943-541x.0001315 · Cited by 211
Experimental analysis of cross-laminated timber panels in fire
Frangi, A., Fontana, M., Hugi, E., & Jübstl, R. (2009) · Fire Safety Journal · doi:10.1016/j.firesaf.2009.07.007 · Cited by 199
Elastic and ductile design of multi-storey crosslam massive wooden buildings under seismic actions
Fragiacomo, M., Dujic, B., & Sustersic, I. (2011) · Engineering Structures · doi:10.1016/j.engstruct.2011.05.020 · Cited by 173
“Since the damage observed in shaking table tests of full-scale multi-storey crosslam buildings was little [11], unlike lightframe construction it is suggested that plasticization should be allowed in the walls at all of the storeys.”
BackgroundMethodInfluentialLehmann, S. (2013) · Sustainable Cities and Society · doi:10.1016/j.scs.2012.08.004 · Cited by 151
Cross-Laminated Timber for Seismic Regions: Progress and Challenges for Research and Implementation
Pei, S., van de Lindt, J. W., Popovski, M., Berman, J. W., Dolan, J. D., Ricles, J., Sause, R., Blomgren, H., & Rammer, D. R. (2016) · Journal of Structural Engineering · doi:10.1061/(asce)st.1943-541x.0001192 · Cited by 150
“As a part of the SOFIE project, a three-story CLT building was designed and tested at Japan’s National Research Institute for Earthquake Science and Disaster Prevention (NIED) shake table facility by Ceccotti (2008) in Tsukuba, Japan.”
MethodInfluential
Metadata
- Authors
- Ceccotti, A.
- Venue
- Structural Engineering International
- Publisher
- Informa UK Limited
- Published
- 2008-05
- Volume
- 18
- Issue
- 2
- Pages
- 156-165
- ISSN
- 1016-8664 (ISSN-L)
- 1683-0350
- OpenAlex
- W1985100292
- Cited by
- 188
- References
- 0
- FWCI
- 9.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.